Trove DMP Kits Installation Guide
Overview:
Altronix T1DMK3F4(D) and T2DMK7F8(D) Trove DMP kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed
Altronix power supply/chargers and sub-assemblies.
T1DMK3F4(D) accommodates up to four (4) DMP 734/734N Wiegand modules for up to four (4) doors in a single enclosure.
T2DMK7F8(D) accommodates up to eight (8) DMP 734/734N Wiegand modules for up to eight (8) doors in a single enclosure.
Configuration Chart:
Altronix
Model
Number
Power Supply Board Input Fuse Rating
Power Supply Board Battery Fuse Rating
120VAC 60Hz Input Current (A)
Maximum Supply
Current for Main
and Aux. Outputs on
Power Supply board
and ACM8(CB) Access
Power Controllers’
outputs
Nominal DC
Output Voltage
Fail-Safe/Fail-Secure or Dry Form “C” Outputs
Additional Fused Outputs
ACM8(CB) Board Input Fuse Rating
ACM8 Board Output Fuse Rating
ACM8CB Board Output PTC Rating
PDS8 Board Input Fuse Rating
PDS8 Board Output Fuse Rating
PDS8CB Board Input PTC Rating
PDS8CB Board Output PTC Rating
[DC]
[Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T1DMK3F4
5A/
250V
10A/
32V
3.5
24VDC @ 6A
20.17-
26.4
20.28-
26.4
–
8
–
–
–
10A/
32V
3A/
32V
–
–
T1DMK3F4D
–
9A
2A
T2DMK7F8
6.3A/
250V
15A/
32V
4.5
24VDC @ 9.4A
8
10A/
250V
2.5A/
250V
–
10A/
32V
3A/
32V
–
–
T2DMK7F8D
–
2.5A
–
–
9A
2A
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper screws; level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s
upper keyholes over the two/three upper screws. Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired
location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure
approximately 2” from the right side
(Fig. 1, pg. 2)
. Connect tamper switch wiring to the
Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount DMP 734/734N Wiegand modules to backplane, refer to
pages 3, 4
.
5. Refer to the
eFlow Power Supply/Charger Installation Guide
for eFlow6NB,
eFlow104NB and corresponding
Sub-Assembly Installation Guides
for ACM8(CB),
PDS8(CB) and VR6 for further installation instructions.
Hardware:
Nylon Spacer | 5/16” Pan Head Screw | Lock Nut
Fig. 1
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure