Overview:

These units convert a 115VAC or 230VAC, 50/60Hz input into a regulated 12VDC or 24VDC output up to 2.5 amp of 
continuous load current (see specifications).

SMP3CTX Series Power Supply Configuration Reference Chart:

Altronix 

Model Number

Accessory Power Distribution Module(s)

Number of Outputs

Fused Outputs

PTC Outputs

Individual Output Rating

Supervised

115VAC/ 230VAC     Input Current

12VDC/ 24VDC Total  Output  Current

SMP3CTX

----

1

----

----

----

---- 0.65 amp / 0.35 amp

2.5 amp

SMP3PMCTX

x

0.65 amp / 0.35 amp

2.5 amp

SMP3PMCTXX

0.65 amp / 0.35 amp

2.5 amp

SMP3PMP4

PD4

4

x

----

3.5 amp

x 0.65 amp / 0.35 amp

2.5 amp

SMP3PMP4CB

PD4CB

----

x

2.5 amp

x 0.65 amp / 0.35 amp

2.5 amp

SMP3PMP8

PD8

8

x

----

3.5 amp

x 0.65 amp / 0.35 amp

2.5 amp

SMP3PMP8CB

PD8CB

----

x

2.5 amp

x 0.65 amp / 0.35 amp

2.5 amp

SMP3PMP16

PD16W

16

x

----

3.5 amp

x 0.65 amp / 0.35 amp

2.5 amp

SMP3PMP16CB PD16WCB

----

x

2.5 amp

x 0.65 amp / 0.35 amp

2.5 amp

Specifications:

Power Supply Voltage Output Specifications:*

Output VDC

Switch Position

Max. Load DC

12VDC

SW1 - Closed (Fig. 1b, pg. 3)

2.5 amp

24VDC

SW1 - Open (Fig. 1b, pg. 3)

2.5 amp

*Specified at 25˚ C ambient.

Installation Instructions:

Wiring methods should be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local 
codes and authorities having jurisdiction. Product is intended for indoor use only. 
1.  Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
  enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s    
  upper keyholes over the two upper screws; level and secure. Mark the position of the lower two holes. Remove the    
  enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two
  upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 4).
  Secure enclosure to earth ground. 
2.  Set SW1 on the power supply board to the desired DC output voltage (Fig. 1c, pg. 3) (Power Supply Voltage
  Output Specification Chart)
.
3.  Connect AC power to the terminals marked [L & N], connect ground to the green flying lead (Fig. 1, pg. 3).
  Use 18 AWG or larger for all power connections (Battery, DC output).
  Use 22 AWG to 18 AWG for power limited circuits (AC Fail/Low Battery reporting).
4.  Measure output voltage before connecting devices. This helps avoiding potential damage.
  CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. 

  There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel.

•  Universal 115VAC/230VAC input.
•  Maximum charge current 0.5 amp.
•  Filtered and electronically regulated outputs.
•  Built-in charger for sealed lead acid or gel type batteries. 
•  Automatic switch over to stand-by battery when
  AC fails (zero voltage drop).
•  AC input and DC output LED indicators.

•  Short circuit and thermal overload protection.
•  Complete with power supply, power distribution module 
  (when applicable), enclosure, cam lock & battery leads. 
•  Power on-off switch.

Supervised models only:

•  AC fail supervision (form “C” contacts). 
•  Low battery supervision (form “C” contacts).

SMP3CTX Series - Installation Guide