Overview: 

These Altronix Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via eight (8) fuse or PTC pro­

tected outputs for powering CCTV cameras, heaters, and other video accessories. 

Rack Mount Configuration Reference Chart: 

Altronix 

utput Voltage

otal Output Current

umber of Outputs

TC Protected Outputs lass 2 power-limited r Dry locations, ass 3 for Wet locations)

use Protected

uto-resettable)

ass 1 Outputs

dividual Output Current ax per output - not to ceed total output current)

use Ratings

imary In-line

5VAC 50/60Hz put Current

gency stings 

Model Number 

O (VAC)

T (Power)

N

P (C fo Cl (a

F Cl

In (m ex

F

Pr Fuse Ratings

11 In

A Li

R248UL 

24VAC 

3.5A 

– 

Yes 

3.5A 

3.5A 

3.5A/ 

250V 

0.85A

28VAC 

3A 

R248ULCB 

24VAC 

3.5A 

Yes 

– 

2.5A 

– 

3.5A/ 

250V 

0.85A

28VAC 

3A 

Specifications: 

Agency Listings: 

•  UL Listed for Commercial 

Closed-Circuit Television Equipment (UL2044). 

CUL Listed - CSA Standard C22.2 No.1-98, Audio, 

Video and Similar Equipment. 

•  CE European Conformity 

Output: 

•  24VAC or 28VAC outputs. 

•  Surge suppression. 

•  Filtered and electronically regulated output. 

•  Short circuit and thermal overload protection. 

Visual Indicators: 

•  Individual power LED indicators. 

•  Illuminated power disconnect circuit breaker 

with manual reset. 

Features: 

•  Unit maintains camera synchronization. 

•  Ease of installation saves time and eliminates 

costly labor. 

•  Removable terminal blocks with locking screw flanges. 

Rack Dimensions 

(H x W x D)

•  2U rack mount chassis for use in standard EIA 19” rack. 

3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm) 

Installation Instructions: 

1.   Mount unit in the desired rack location (Space unit at least 3” from any video monitors), Do not obstruct side air vents. 

2.   Set power disconnect circuit breaker to OFF position (Fig. 1d, pg. 3). 

3.   All units are factory set for 24VAC operation. 

For 28VAC operation, adjust unit prior to mounting and applying power as follows: 

Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and the yellow wire 

[24V] is connected to the terminal marked [S]. 

Note: R248ULCB set for 28VAC operation is not Class 2 Rated, not power-limited. 

4.   Plug power cord into a grounded 115VAC 50/60 Hz receptacle (Fig. 1c, pg. 3), ground should be connected 

as indicated in (Fig. 1e, pg. 3). 

5.   Set power disconnect circuit breaker to RESET (ON) position (Fig. 1d, pg. 3)

6.   Measure output voltage before connecting devices. This helps avoiding potential damage. All terminals with 

common suffix (P) “1P, 2P...” are the same polarity. 

7.   Set power disconnect circuit breaker to OFF position (Fig. 1d, pg. 3). 

8.   Connect devices to removable terminal blocks marked [1P & 1N] through [8P & 8N] for eight (8) output models 

(Fig. 1a, pg. 3). Lock down the terminal blocks by tightening the screws on the flanges after the wiring 

has been completed. 

9.   Upon completion of the wiring set power disconnect circuit breaker to RESET (ON) position (Fig. 1d, pg. 3)

10.  Green power LEDs on faceplate will illuminate when power is present. When an output is in a trouble condition 

(blown fuse or tripped PTC), the corresponding LED will not be illuminated (Fig. 1, pg. 3)

a.  Blown fuse (R248UL) - Set power disconnect circuit breaker on back of unit to the OFF position (Fig. 1d, pg. 3). 

Remove front faceplate to access fuses. Replace with fuses rated @ 3.5A/250VA (Altronix model # Fuse1). 