background image

 

- 2 - 

R248UL Series Installation Guide

Installation Instructions:

1.  Mount unit in the desired rack location (Space unit at least 3” from any video monitors). 

 

Do not obstruct side air vents.

2.  Set power disconnect circuit breaker to OFF position 

(Fig. 1d, pg. 3).

3.  All units are factory set for 24VAC operation. 

 

For 28VAC operation, adjust unit prior to mounting and applying power as follows: 

 

Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and the 

 

yellow wire [24V] is connected to the terminal marked [S].

 

Note: R248ULCB set for 28VAC operation is not Class 2 Rated, not power-limited.

4.  Plug power cord into a grounded 115VAC 50/60 Hz receptacle

 (Fig. 1c, pg. 3)

, ground should be connected 

 

as indicated in 

(Fig. 1e, pg. 3).

5.  Set power disconnect circuit breaker to RESET (ON) position 

(Fig. 1d, pg. 3)

6.  Measure output voltage before connecting devices. This helps avoiding potential damage. 

 

All terminals with common suffix (P) “1P, 2P...” are the same polarity.

7.  Set power disconnect circuit breaker to OFF position 

(Fig. 1d, pg. 3).

8.  Connect devices to removable terminal blocks marked [1P & 1N] through [8P & 8N] for eight (8) output 

 models 

(Fig. 1a, pg. 3)

. Lock down the terminal blocks by tightening the screws on the flanges after the 

 

wiring has been completed.

Agency Listings:

•  UL Listed for Commercial 

  Closed-Circuit Television Equipment (UL2044).

  CUL Listed - CSA Standard C22.2 No.1-98, 

  Audio, Video and Similar Equipment.

•  CE European Conformity

Output:

•  24VAC or 28VAC outputs.

•  Surge suppression.

•  Filtered and electronically regulated output.

•  Short circuit and thermal overload protection.

Visual Indicators:

•  Individual power LED indicators.

Visual Indicators 

(cont’d)

:

•  Illuminated power disconnect circuit breaker 

  with manual reset.

Features:

•  Unit maintains camera synchronization.

•  Ease of installation saves time and 

  eliminates costly labor.

•  Removable terminal blocks with 

  locking screw flanges.

Rack Dimensions 

(H x W x D)

:

•  2U rack mount chassis for use in 

  standard EIA 19” rack.

  3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)

Overview:

Altronix R248UL Series Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via eight (8) fuse 

or PTC protected outputs for powering CCTV cameras, heaters, and other video accessories.

Eight (8) Output Rack Mount Configuration Reference Chart:

Altronix 

Model Number

Output Voltage (VAC)

Total 

 Output Current

(Power)

Number of Outputs

PTC Protected auto-resettable  Outputs (Class 2 power-limited for Dry locations,  Class 3 for Wet locations)

Fuse Protected Class 1 Outputs

Individual Output Current (max per output - not to exceed

 

total output current)

Fuse Ratings

Primary In-line Fuse Ratings

115VAC 50/60Hz Input Current

Agency Listings

R248UL

24VAC

3.5A

8

P

3.5A

3.5A

3.5A/

250V 0.85A

28VAC

3A

R248ULCB

24VAC

3.5A

8

P

2.5A

3.5A/

250V 0.85A

28VAC

3A

Specifications:

Отзывы: