- 2 -
R2416UL Series
Overview:
Altronix R2416UL Series Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via sixteen
(16) fuse or PTC protected outputs for powering CCTV cameras, heaters and other video accessories.
Sixteen (16) Output Rack Mount Configuration Reference Chart:
Altronix
Model Number
Output Voltage
(VAC)
Total
Output
Current (Power)
Number of Outputs
PTC Protected auto-
resettable Outputs
(Class 2 power-limited
for Dry locations,
Class 3 for Wet locations)
Fuse Protected Class 1
Outputs
Individual Output
Current (max per
output - not to exceed
total output current)
Fuse Ratings
Primary In-line
Fuse Ratings
115VAC 50/60Hz
Input Current
Agency
Listings
R2416UL
24VAC
3.5A
8
–
P
3.5A
3.5A
3.5A/
250V
2.9A
28VAC
3A
R2416ULCB
24VAC
3.5A
8
P
–
2.5A
–
3.5A/
250V
2.9A
28VAC
3A
R2416300UL
24VAC
12.5A
16
–
P
3.5A
3.5A
–
3A
28VAC
10A
R2416300ULCB
24VAC
12.5A
16
P
–
2.5A
–
–
3A
28VAC
10A
R2416600UL*
24VAC
25A
16
–
P
3.5A
3.5A
–
6A
28VAC
20A
R2416600ULCB
24VAC
25A
16
P
–
2.5A
–
–
6A
28VAC
20A
*24VAC models: Outputs 1-8 provide 12.5A (300VA) max. Outputs 9-16 provide 12.5A (300VA) max.
*28VAC models: Outputs 1-8 provide 10A (280VA) max. Outputs 9-16 provide 10A (280VA) max.
Specifications:
Installation Instructions:
1. Mount unit in the desired rack location (space unit at least 3” from any video monitors).
Do not obstruct side air vents.
2. Set power disconnect circuit breaker to OFF position (Fig. 1d, pg. 3).
3. The unit is factory set for 24VAC operation.
For 28VAC operation, adjust unit prior to mounting and applying power as follows:
a. Open bottom of the unit by removing six (6) screws (Rack Mechanical Drawing and Dimensions, pg. 4).
b. Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and
the yellow wire [24V] is connected to the terminal marked [S].
c. After securing all wires for proper voltage place bottom panel back on the unit and fasten with the
six (6) screws.
Note: R2416ULCB set for 28VAC operation is not Class 2 Rated, not power-limited.
4. Plug power cord into a grounded 115VAC 50/60 Hz receptacle (Fig. 1c, pg. 3), ground should be connected
as indicated in (Fig. 1e, pg. 3).
5. Set power disconnect circuit breaker to RESET (ON) position (Fig. 1d, pg. 3).
6. Measure output voltage before connecting devices. This helps avoiding potential damage.
All terminals with common suffix (P) “1P, 2P...” are the same polarity.
Agency Listings:
• UL Listed for Commercial
CCTV Equipment (UL 2044).
CUL Listed - CSA Standard C22.2 No. 1-98,
Audio, Video and Similar Equipment.
• CE European Conformity.
Output:
• 24VAC or 28VAC outputs (Factory set @ 24VAC).
• Surge suppression.
• Filtered and electronically regulated output.
• Short circuit and thermal overload protection.
Visual Indicators:
• Sixteen (16) individual power LED indicators.
Visual Indicators
(cont’d)
:
• Illuminated power disconnect circuit breaker
with manual reset.
Features:
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates
costly labor.
• Removable terminal blocks with locking
screw flanges.
Rack Dimensions
(H x W x D)
:
• 2U rack mount chassis for use in standard
EIA 19” rack.
3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)