background image

 

- 2 - 

R2416UL Series

Overview:

Altronix R2416UL Series Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via sixteen 

(16) fuse or PTC protected outputs for powering CCTV cameras, heaters and other video accessories.

Sixteen (16) Output Rack Mount Configuration Reference Chart:

Altronix 
Model Number

Output Voltage

(VAC)

Total 

 Output 

Current (Power)

Number of Outputs

PTC Protected auto-

resettable Outputs 

(Class 2 power-limited 

for Dry locations, 

Class 3 for Wet locations)

Fuse Protected Class 1 

Outputs

Individual Output

 

Current (max per

 

output - not to exceed

 

total output current)

Fuse Ratings

Primary In-line

Fuse Ratings

115VAC 50/60Hz

Input Current

Agency

Listings

R2416UL

24VAC

3.5A

8

P

3.5A

3.5A

3.5A/
250V

2.9A

28VAC

3A

R2416ULCB

24VAC

3.5A

8

P

2.5A

3.5A/
250V

2.9A

28VAC

3A

R2416300UL

24VAC

12.5A

16

P

3.5A

3.5A

3A

28VAC

10A

R2416300ULCB

24VAC

12.5A

16

P

2.5A

3A

28VAC

10A

R2416600UL*

24VAC

25A

16

P

3.5A

3.5A

6A

28VAC

20A

R2416600ULCB

24VAC

25A

16

P

2.5A

6A

28VAC

20A

*24VAC models: Outputs 1-8 provide 12.5A (300VA) max. Outputs 9-16 provide 12.5A (300VA) max.
*28VAC models: Outputs 1-8 provide 10A (280VA) max. Outputs 9-16 provide 10A (280VA) max.

Specifications:

Installation Instructions:

1.  Mount unit in the desired rack location (space unit at least 3” from any video monitors). 

 

Do not obstruct side air vents.

2.  Set power disconnect circuit breaker to OFF position (Fig. 1d, pg. 3).

3.  The unit is factory set for 24VAC operation. 

 

For 28VAC operation, adjust unit prior to mounting and applying power as follows: 

 

a.  Open bottom of the unit by removing six (6) screws (Rack Mechanical Drawing and Dimensions, pg. 4).

 

b.  Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and 

 

  the yellow wire [24V] is connected to the terminal marked [S].

 

c.  After securing all wires for proper voltage place bottom panel back on the unit and fasten with the 

 

  six (6) screws.

 

Note: R2416ULCB set for 28VAC operation is not Class 2 Rated, not power-limited.

4.  Plug power cord into a grounded 115VAC 50/60 Hz receptacle (Fig. 1c, pg. 3), ground should be connected 

 

as indicated in (Fig. 1e, pg. 3).

5.  Set power disconnect circuit breaker to RESET (ON) position (Fig. 1d, pg. 3).

6.  Measure output voltage before connecting devices. This helps avoiding potential damage.

 

All terminals with common suffix (P) “1P, 2P...” are the same polarity. 

Agency Listings:

•  UL Listed for Commercial 

  CCTV Equipment (UL 2044).

  CUL Listed - CSA Standard C22.2 No. 1-98, 

  Audio, Video and Similar Equipment.

•  CE European Conformity.

Output:

•  24VAC or 28VAC outputs (Factory set @ 24VAC).

•  Surge suppression.

•  Filtered and electronically regulated output.

•  Short circuit and thermal overload protection.

Visual Indicators:

•  Sixteen (16) individual power LED indicators.

Visual Indicators 

(cont’d)

:

•  Illuminated power disconnect circuit breaker 

  with manual reset.

Features:

•  Unit maintains camera synchronization.

•  Ease of installation saves time and eliminates 

  costly labor.

•  Removable terminal blocks with locking 

  screw flanges.

Rack Dimensions 

(H x W x D)

:

•  2U rack mount chassis for use in standard 

  EIA 19” rack.

  3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)

Отзывы: