Recommended Altronix SFP Modules:

Altronix P1MM and P1SM10 are hot-pluggable SFP fiber transceiver modules and are readily usable with all 
Altronix Spectrum fiber optic equipment for 1Gb transmission rates. 
P1MM - For use with Multi-Mode Fiber for distances up to 550m. 
P1SM10 - For use with Single-Mode Fiber for distances up to 10km.

Typical Application:

Fig. 2

Technical Specifications:

Parameter

Description

Number of Ports
(SFP / Ethernet)

NetWaySP8A: 

Eight (8) Gigabit SFP Ports. 

 

Eight (8) ports 10/100/1000Mbps Ethernet ports.

NetWaySP16A:  Sixteen (16) Gigabit SFP Ports. 
 

Sixteen (16) ports 10/100/1000Mbps Ethernet ports.

Input Power 
Requirements

NetWaySP8A: 

115VAC, 60Hz, 0.5A or 230VAC, 50/60Hz, 0.3A.

NetWaySP16A:  115VAC, 60Hz, 1.0A or 230VAC, 50/60Hz, 0.5A.

Environmental 
Conditions

Operating Ambient Temperature (50W): – 40ºC to 50ºC (– 40ºF to 122ºF)
Relative Humidity: 85%, +/– 5%
Storage Temperature: – 40ºC to 85ºC (– 40ºF to 185ºF).
Operating Altitude: – 304.8 to 2,000m.

Regulatory 
Compliance

UL/cUL Listed for Information Technology Equipment (UL 60950-1)

CE European Conformity.

Weights (approx.)

NetWaySP8A: 

Product: 3.81 lb. (1.72kg) | 

Shipping: 6.00 lb. (2.72kg)

NetWaySP16A:  Product: 4.5 lb. (2.04kg) | 

Shipping: 6.69 lb. (3.03kg)

NetWaySP16A - Rear Panel

NetWaySP16A - Front Panel

115/230VAC Input

Fiber from

NetWaySP16A

Fiber from

NetWaySP16A

Data & PoE

30W/60W

NetWay Spectrum

Ethernet over Fiber

PoE Switch

or

Media Converter

Data & PoE

30W/60W

NetWay Spectrum

Ethernet over Fiber

PoE Switch

or

Media Converter

 

4

 

10 

11 

12

 

8

 

13 

14 

15 

16

Switch

SFP 9

SFP 10

SFP 11

SFP 12

SFP 13

SFP 14

SFP 15

SFP 16

SFP 1

SFP 2

SFP 3

SFP 4

SFP 5

SFP 6

SFP 7

SFP 8

I.T.E. 43KC

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence 
of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to 
constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating 
and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION: To reduce the risk of electric shock do not open enclosure. 
There are no user serviceable parts inside. Refer servicing to qualified service personnel.

All manuals and user guides at all-guides.com

Отзывы: