background image

NetWay8M/NetWay16M 

 - 3 -

Fig. 1

1a  OUT 1-8 (NetWay8M), OUT  1-16 (NetWay16M): Structured cable to PoE compliant cameras/edge devices.
1b  IN 1-8 (NetWay8M), IN 1-16 (NetWay16M): Structured cable to ethernet switch or video server.
1c  LED(s) 1-8 (NetWay8M), 1-16 (NetWay16M): Port status LEDs.
1d  Reset: Restores unit to factory settings.
1e  + --- , PoE Shutdown: Low voltage trigger input (see Technical Specifications pg. 5).
1f
 

Ethernet: LAN or laptop connection enables NetWayM programming and status monitoring. 

AC POWER

NetWay8M & NetWay16M - Rear Panel

NetWay8M - Front Panel

NetWay16M - Front Panel

+  PoE  --

SHUTDOWN

+  PoE  --

SHUTDOWN

1a

1b

1c

1d 1e

1f

1g

1h

 

Note: All interconnected devices must be UL Listed.

7.  Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) 

 position 

(Fig. 1g, pg. 3).

8.  Port status LEDs on the NetWayM will initialize when PoE devices are connected as follows:

  -  LED will illuminate when devices are IEEE 802.3af compliant.

  -  LED will blink once and illuminate when devices are IEEE802.3at compliant (PoE Plus).

9.  To utilize the PoE shutdown feature it is necessary to do the following:

  a.  Connect a device that will provide a low voltage trigger input (see Technical Specifications pg. 5) to terminals 

   

marked [+ --- , PoE Shutdown] on the NetWayM (Fig. 1e, pg. 2). When voltage is applied, the PoE shutdown

   

enabled PoE port(s) will drop to zero volts. Removing the low voltage trigger input at the [+ --- , PoE shutdown]

   

terminals will allow the PoE port(s) to operate normally and supply power to PoE compliant devices. Power will

   

reset in approximately 4 seconds. Although there is no output voltage to power PoE devices during shutdown, data

   

signals may still be present on the data pair lines of the structured cable.

  b.  Individual ports must be programmed utilizing the user interface (see User Interface and Programming, pgs. 6 & 7).

Port Status and LED Flash Codes:

Port Status

Flash Codes

Description

All Ports Off

Sequential LED Port Scan

No devices connected

Port Off

OFF

LED OFF

Port On

ON

LED ON

Class 4 detection Port

Blinks 2 times

Enables power to PoE devices.

Non-compliant Device

2Hz

Will prevent port from turning on.

Port Overload Fault

5Hz

Will prevent port from turning on.

4 Port Overload Grouped

5Hz

4 LEDs

Will prevent ports from turning on.

8 Port Overload Grouped

5Hz

LED’s 1-8 Power Supply Overload for ports 1-8.

LED’s 9-16 Power Supply Overload for ports 9-16.

Содержание NetWay16M

Страница 1: ...E Managed Midspan Solution for Standard Network Infrastructure Installation Guide Models Include NetWay8M NetWay16M Eight 8 Port PoE Midspan Injector Sixteen 16 Port PoE Midspan Injector DOC NETM Rev 052110 More than just power ...

Страница 2: ...W adapter for non PoE compliant IP cameras For UL 60950 1 applications only NetWay3012 25W adapter for non PoE compliant IP fixed or PTZ cameras For UL 60950 1 applications only NetWayXT PoE repeater module extends range 100m 328 ft For UL 60950 1 applications only Installation Instructions Wiring methods shall be in accordance with the National Electrical Code ANSI NFPA70 local codes and the auth...

Страница 3: ...do the following a Connect a device that will provide a low voltage trigger input see Technical Specifications pg 5 to terminals marked PoE Shutdown on the NetWayM Fig 1e pg 2 When voltage is applied the PoE shutdown enabled PoE port s will drop to zero volts Removing the low voltage trigger input at the PoE shutdown terminals will allow the PoE port s to operate normally and supply power to PoE c...

Страница 4: ...able from port marked OUT on NetWay3012M to the IP fixed or PTZ camera Fig 3 pg 5 4 Connect 12VDC output from NetWay3012 terminals marked 12VDC to the power input of the IP camera Fig 3 pg 5 Polarity must be observed 5 Power LED indicator will illuminate on NetWay3012 under normal conditions Fig 3 pg 5 Installing NetWayXT repeater module 1 Mount NetWayXT in desired location utilizing the mounting ...

Страница 5: ...ronmental Conditions Operating Ambient Temperature UL60950 1 32ºF to 104ºF 0ºC to 40ºC UL294 32ºF to 120 2ºF 0ºC to 49ºC Relative humidity 85 5 Storage Temperature 4º to 158ºF 20º to 70ºC Storage Operating Altitude 1000 to 10 000 ft 304 8 to 3048m Regulatory Compliance UL CUL Listed for Information Technology Equipment UL 60950 1 UL Listed for Access Control Systems UL 294 CE approved NetWay8M Car...

Страница 6: ...lowing IP address option e Set the IP address to 192 168 168 15 or another valid IP address on the same network f Click OK Close all windows Step 2 Connect a laptop or PC to the Ethernet port of your NetWayM unit The NetWayM unit should be powered up at this moment Step 3 Open a browser window it is necessary to update your browser software to the latest version so that the pages display and funct...

Страница 7: ...click on the Enable radio button s in the PoE shutdown column Fig 5 pg 7 2 To disable PoE shutdown for one or more ports click on the Disable radio button s in the PoE shutdown column Fig 5 pg 7 Note To enable or disable PoE shutdown for all ports click on corresponding link below PoE shutdown column 3 Click Submit to save the changes or proceed with programming Power Allocation Mode NetWayM featu...

Страница 8: ...the LAN Additional information 1 If using DHCP all settings will be detected automatically While DHCP is a useful tool for determining the network settings if you set up your NetWay8M NetWay16M in this manner its IP address may change at different times for different reasons particularly after a power failure If the IP address of the NetWay8M NetWay16M changes you may have difficulties accessing y...

Страница 9: ...hoosing a port commonly used for another purpose like port 25 for SMTP mail or port 448 for secure sockets choose an unusual port number For example add 50 000 to your house number 50 123 is less likely to lead to a port conflict For a list of the known and registered ports see http www iana org assignments port numbers Reset Features Reset Password 1 Set illuminated master power disconnect circui...

Страница 10: ...be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There are no user serviceable parts inside Refer servicing to qualif...

Страница 11: ...es of rack chassis Fig 7a 2 Install mounting brackets A on the left and right side of rack chassis using the four 4 flat head screws B included Fig 7b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not included Fig 7c Fig 9 Fig 8 Shelf Installation 1 Position and affix rubber pads C included at each corner on the bottom of the unit Fig 9 2 Place unit in desired loca...

Страница 12: ...y typographical errors Product specifications are subject to change without notice 140 58th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Made in U S A IINetWay8M NetWay16M L03M Notes MEMBER ...

Отзывы: