NetWay1 / NetWay1X
- 3 -
NetWay1 Port Status and LED Flash Codes
Port Status
Flash Code
Flash Pattern
Port is not powered
or disconnected
OFF
LED OFF
Port is connected to a valid
PD and powered
ON
LED ON
Overcurrent fault during
port power-on
2 Flashes
LED ON
l l
Z Z
(once)
l l
LED ON
Invalid low or high discovery
signature resistance
5 Flashes
l l l l
Z Z
Z Z Z
l l l l
Typical Applications (NetWay1 and NetWay1X):
Fig. 3
Fig. 4
Fig. 5
Fig. 6 - Typical UL294 application (NetWay1 only):
NVR/Network Server
Network Switch
NetWay1
CAT5e - 100m
Port shutdown
input
UL Listed
Access Control
Power Limited
Power Supply
24VDC/24VAC
Card
Reader
Electric
Strike
HID
Solo Edge
Device
Video Monitor
NVR/Network Server
Network Switch
NetWay1/NetWay1X
PoE Camera
CAT5e - 100m
Port shutdown
input
24VAC/
24VDC
input
Video Monitor
NVR/Network Server
Network Switch
NetWay1/NetWay1X
CAT5e - 100m
Port shutdown
input
24VAC/
24VDC
input
NetWay1512
12VDC
IP Camera
Video Monitor
NVR/Network Server
Network Switch
NetWay1/NetWay1X
CAT5e - 100m
Port shutdown
input
24VAC/
24VDC
input
CAT5e - additional 100m
NetwayXT
PoE Camera