Maximal3D/Maximal5D/Maximal7D Access Power Controllers (PTC)
- 9 -
+
DC
---
BAT FAIL
NO C NC NO C NC
+ BA
T
---
AC FAIL
Power Supply Board
L G N
Earth
Ground
Line
Neutral
115VAC Input
60 Hz.
Tamper Switch
Wire
Strap
(from
Enclosure
to Door)
12VDC Rechargeable
Battery**
(Optional)
12VDC Rechargeable
Battery**
(Optional)
*12VDC operation:
For 12VDC operation only a single battery is needed.
Connect red battery lead to terminal
marked [+ BAT] and to the
[positive (+)] terminal of the
battery.
Connect black battery lead
to terminal marked
[BAT -- ] and to the
[negative (--)] terminal
of the battery.
+ BAT ---
12VDC Rechargeable
Battery*
(Optional)
**24VDC operation: Connect two (2) 12VDC
batteries in series
---
DC
+
Fig. 3
Maximal3D
Maximal5D
Fig. 3a
Fig. 3b
Edge of
Enclosure
to Access Control Panel
or U.L. Listed
Reporting Device
Enclosure
Sentrol
model # 3012
Tamper Switch
or equivalent
(Not Included)