background image

 

- 6 - 

HubWay8D / HubWay16D Installation Guide

115VAC

Input, 50/60Hz

Video

Power

Video

Data

Power

Video

Power

HubWayDv/Dvi

Video Balun

Combiner

CAT-5

CAT-5

CAT-5

HubWayAv

Video Balun

Combiner

PTZ

Camera

PTZ

Camera

PTZ

Camera

Data

Video

Head End Equipment (DVR)

RS485

Video (Coax)

Four (4) Video

signals on a

single CAT-5

Data
(CAT-5)

Power

Fixed

Camera

Fixed

Camera

Fixed

Camera

Fixed

Camera

HubWayDv/Dvi

Video Balun

Combiner

Video

Data

Power

Video

Data

Power

HubWayAv

Video Balun

Combiner

HubWayAv

Video Balun

Combiner

Max.

video

750 ft.

Video

Power

HubWayDv/Dvi

Video Balun

Combiner

CAT-5

24VAC/28VAC

Camera Power

Provided

by HubSat4D

Video

Data

Power

Outdoor

NEMA

Rated

Power

Supply

Outdoor

PTZ

Camera

115VAC Input,

50/60Hz

HubWayAv or

HubWayDv/Dvi

Video Balun

Combiner

Monitor

Rear

Front

1

2

3

4

CH 1-4

CH 5-8

28VAC
OFF
24VAC

+ DATA -

1-8

5

6

7

8

AC POWER

8

7

6

5

4

3

2

1

Typical Applications:

Fig. 4

Fig. 4a - 

Optional hookup utilizing HubSat4D.

Содержание HubWayD Series

Страница 1: ...P Transceiver Hub with Integral Camera Power HubWay162D UL Listed sixteen 16 Channel Passive UTP Transceiver Hub with Integral Camera Power Includes sixteen 16 UL Listed Accessory HubWayAv Video Balun Combiners HubWay163D UL Listed sixteen 16 Channel Passive UTP Transceiver Hub with Integral Camera Power Includes sixteen 16 UL Listed Accessory HubWayDv Video Balun Combiners HubWayD Series Passive ...

Страница 2: ...ted 1A per channel Surge suppression Visual Indicators AC input power indicator Features Illuminated master power disconnect circuit breaker with manual reset IEC 320 3 wire grounded line cord detachable Unit can be rack wall or shelf mounted 1U rack mount chassis for standard EIA 19 rack Accessories Video Balun Combiners HubWayAv for use with 24VAC cameras HubWayAv2 for use with 24VAC cameras Hub...

Страница 3: ...the maximum distance for power transmission a local external power source is required Optionally an Altronix HubSat4D Passive UTP Transceiver Hub with Integral Camera Power may be utilized Fig 4a pg 6 The combined total cable distance must not exceed 750 ft for video transmission between the HubWay8 16 and each camera routed through the HubSat4D 10 Set illuminated master power disconnect circuit b...

Страница 4: ...be utilized for the data transmission to PTZ s 1d Output voltage switches Selects 24VAC 28VAC OFF for each output 1b Channels 1 4 Channels 5 8 Channels 9 12 Channels 13 16 CAT 5 or higher structured cable from optional HubSat4D enables video transmission from up to four 4 cameras 1g IEC 320 Connector 115VAC 60Hz 230VAC 50 60Hz grounded line cord included Fig 1 1e Data Removable terminal blocks for...

Страница 5: ...ector of Camera To BNC Connector of Camera Structured Cable from HubWay8CD or HubWay16CD Structured Cable from HubWay8CD or HubWay16CD VIDEO BALUN COMBINER HubWayDv CAT5 DATA 12VDC Wire Connectors Also Available as HubWayDvi Video Balun Combiner for non isolated 12VDC cameras Fig 2 Fig 2a Fig 2c Fig 2b Fig 2d Fig 2e HubWayAV2 Video from Camera Data to Camera Power to Camera Cat5 back to HubWay or ...

Страница 6: ...era Fixed Camera HubWayDv Dvi Video Balun Combiner Video Data Power Video Data Power HubWayAv Video Balun Combiner HubWayAv Video Balun Combiner Max video 750 ft Video Power HubWayDv Dvi Video Balun Combiner CAT 5 24VAC 28VAC Camera Power Provided by HubSat4D Video Data Power Outdoor NEMA Rated Power Supply Outdoor PTZ Camera 115VAC Input 50 60Hz HubWayAv or HubWayDv Dvi Video Balun Combiner Monit...

Страница 7: ...eaker tripped Switch not illuminated RESET ON position Switch illuminated The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert ...

Страница 8: ...flat head screws B included Fig 7a 2 Place unit at desired location and secure with mounting screws not included Fig 7b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing Fig 7 Fig 7a Fig 7b B A Fig 8 Shelf Installation 1 Position and affix rubber pads C included at each corner on the bottom of the unit Fig 8 2 Place unit in desired location A B C ...