background image

 

HubWay8DS 

- 3 -

Installation Instructions:

1.  Set the input voltage selector switch located on the left side of the HubWay8DS unit for 115VAC or 
 

230VAC operation (Fig. 1h, pg. 4).

2.  Attach mounting brackets to HubWay unit for rack or wall mount installation (Figs. 6-7, pg. 8). Affix rubber 
 

pads to HubWay for shelf installation (Fig. 8, pg. 8).

3.  Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at 
 

least 3” from any video monitors).

4.  Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5, pg. 7).
5.  Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWay8DS unit 
 

(Fig. 1e, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle.

6.  Set voltage output selector switch of each camera channel for 24VAC or 28VAC (Fig. 1a, pg. 4).
7.  Connect the BNC video outputs for HubWay8DS Channels 1-8 to the corresponding video inputs on the 
 

headend equipment (DVR) (Fig. 1d, pg. 4).

8.  Connect the RS422/RS485 output of the head end equipment (DVR) to the data input terminal block of
 

the HubWay8DS unit (polarity must be observed) (Fig. 1c, pg. 4)

9.  Connect Video Balun/Combiner at camera 1 to the HubWay8DS unit utilizing CAT-5 or higher structured 
 

cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1] 

 

of the HubWay8DS (Fig. 1g, pg. 4). Plug the RJ45 connector at the opposite end of the structured cable 

 

into the RJ45 jack of the Video Balun/Combiner located at camera 1.

 

•  For 24VAC cameras use Altronix model HubWayAv/HubWayAv2 Video Balun/Combiner 

  (Figs. 2a, 2b, 2e, pg. 5).
 

•  For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 5).

 

•  For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner 

  (Figs. 2c, 2d, pg. 5).
 

Repeat steps 6-9 for each additional camera (Channels 2-8).

 

Note: When a particular camera exceeds the maximum distance for power transmi  ssion, a local 

 

external power source is required. Optionally, an Altronix HubSat Passive UTP Transceiver Hub with 

 

Integral Camera Power unit may be utilized (Fig. 4a, pg. 6). The combined total cable distance must not 

 

exceed 750 ft. for video transmission between the HubWay8DS and each camera routed through the 

 

HubSat4D unit.

10.  Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and 
 

measure the output voltage at the power output of each Video Balun/Combiner (Figs. 2b, 2d, pg. 5) before 

 

powering each camera to ensure proper operation and avoid possible damage.

 

•  HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 2a, 2b, 2e, pg. 5).

 

•  HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 5).

11.  Set illuminated master power disconnect circuit breaker to the (OFF) position to make the final connections
 

(Fig. 5, pg. 7).

12.  Connect the power outputs of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/
 

Combiners to the power inputs of the cameras (Figs. 2a-2e, pg. 5). Polarity must be observed.

13.  Connect the terminals marked [+ DATA –] of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi 
 

Video Balun/Combiners to the data terminals of the cameras for PTZ control (Figs. 2a-2e, pg. 5). Polarity 

 

must be observedWhen using fixed cameras disregard this step.

14.  Connect the BNC connectors of the HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the 
 

BNC video outputs of the cameras (Figs. 2a-2e, pg. 5).

15.  Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) 
 position 

(Fig. 5, pg. 7). 

16.  The power LEDs (Red) located on the front of the HubWay8DS will illuminate when AC power is present 
 

(Fig. 1c, pg. 4).

 

Note: If any of these LEDs are not illuminated either a voltage output selector switch is in the OFF position 

 

or the  PTC is tripped for that channel.

 

To reset the PTC:

 

1.  Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must 

 

 

remain in the OFF position for approximately 2 minutes in order for the PTC to reset.

 

2.  Eliminate the trouble condition (short circuit or overload).

 

3.  Set the voltage output selector switch for 24VAC or 28VAC (Fig. 1a, pg. 4).

17.  AC LEDs (Green) of the HubWayAv or DC LEDs (Red) of the HubWayDv/HubWayDvi Video Balun/
 

Combiners will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 5). 

Содержание HubWay8DS

Страница 1: ...nnel Passive UTP Transceiver Hub with Integral Camera Power HubWay82DS UL Listed eight 8 Channel Passive UTP Transceiver Hub with Integral Camera Power Includes eight 8 UL Listed Accessory HubWayAv Video Balun Combiners HubWay83DS UL Listed eight 8 Channel Passive UTP Transceiver Hub with Integral Camera Power Includes eight 8 UL Listed Accessory HubWayDv Video Balun Combiners ...

Страница 2: ...8 channels of video over twisted pair up to 750 ft Eight 8 75 Ohm video outputs Data RS422 RS485 data inputs Power Individually selectable 24VAC or 28VAC power outputs with OFF position Unit provides up to 1A max per channel not to exceed a total of 5A 150VA maximum current PTCs are rated 1A per channel Surge suppression Visual Indicators AC input power indicator Eight 8 power LED indicators Featu...

Страница 3: ...ub with Integral Camera Power unit may be utilized Fig 4a pg 6 The combined total cable distance must not exceed 750 ft for video transmission between the HubWay8DS and each camera routed through the HubSat4D unit 10 Set illuminated master power disconnect circuit breaker to the RESET ON position Fig 5 pg 7 and measure the output voltage at the power output of each Video Balun Combiner Figs 2b 2d ...

Страница 4: ...rol 1d BNC Connector Video outputs to head end equipment DVR 1a Output voltage switches Selects 24VAC 28VAC OFF for each output 1f Channels 1 4 Channels 5 8 Links HubSat units enabling video transmission of up to four 4 cameras over a single CAT 5 structured cable 1e IEC 320 Connector 115VAC 230VAC 50 60Hz grounded line cord included Fig 1 1c Data Removable terminal blocks for RS422 RS485 input fr...

Страница 5: ...J45 Jack RJ45 Jack To BNC Connector of Camera To BNC Connector of Camera Structured Cable from HubWay8CD or HubWay16CD Structured Cable from HubWay8CD or HubWay16CD VIDEO BALUN COMBINER HubWayDv CAT5 DATA 12VDC Wire Connectors Also Available as HubWayDvi Video Balun Combiner for non isolated 12VDC cameras Fig 2 Fig 2a Fig 2c Fig 2b Fig 2d Fig 2e HubWayAV2 Video from Camera Data to Camera Power to ...

Страница 6: ...itor HubWayDv Dvi Video Balun Combiner Video Data PTZ Camera PTZ Camera PTZ Camera Power Video Data Power HubWayAv Video Balun Combiner CAT 5 HubWayAv Video Balun Combiner CAT 5 Max video 750 ft Video Power HubWayDv Dvi Video Balun Combiner CAT 5 Video Data Outdoor PTZ Camera CAT 5 HubWayAv or HubWayDv Dvi Video Balun Combiner IEC 320 Connector 115VAC 60 Hz AC POWER 8 7 6 5 4 3 2 1 24VAC OFF 28VAC...

Страница 7: ... the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There are no user serviceable parts inside Refer servicing to qualified service personnel 1U EIA 19 Rack Mount Chassis Dimensions H x W x D approximate 1 625 x 19 125 x 8 5 41 3mm x 486mm x 216mm 1 625 41 3mm 8 5 215 9mm 0 75 19 05mm 19 125 486mm 17 625 447 7mm AC POWER 8 7 6 5 4 3 2 1 24V...

Страница 8: ...c A B Fig 6b Fig 6a Fig 6 Fig 6c Top Top Top Front Left Front Left Front Left Remove Wall Mount Installation 1 Install mounting brackets A on the left and right side of rack chassis using four 4 flat head screws B included Fig 7a 2 Place unit at desired location and secure with 6 size screws or larger not included Fig 7b Caution It is necessary to make sure mounting screws are securely fastened to...