HubWay Passiive Unit 

- 3 -

   Installation  Instructions:

1.  Set the input voltage selector switch located on the left side of the HubWay8Di/16Di unit (facing front panel)
 

for 115VAC or 230VAC operation (Fig. 1h, pg. 4).

2.  Attach mounting brackets to HubWay unit for rack or wall mount installation (Figs. 6-7, pg. 8). Affix rubber pads 
 to 

HubWay for shelf installation (Fig. 8, pg. 8).

3.  Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3” 
 

from any video monitors).

4.  Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5, pg. 7).
5.  Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWay8Di/HubWay16Di
 unit 

(Fig. 1g, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle.

6.  Set voltage output selector switch of each camera channel  for 24VAC or 28VAC (Fig. 1d, pg. 4).
7.  Connect the BNC video outputs for HubWay8Di/16Di Channels 1 - 8 (Channels 1-16) to the
 

corresponding video inputs on the head end equipment (DVR) (Fig. 1f, pg. 4).

8.  Connect the RS422/RS485 output of the head end equipment (DVR) to the one (1) or both data input terminal 
 

blocks of the HubWay8Di/16Di unit (polarity must be observed) (Fig. 1e, pg. 4)

 

Note: The Data input terminals of the HubWay8Di/16Di must be wired in parallel for proper operation. 

 

When using fixed cameras disregard this step.

9.  Connect Video Balun/Combiner at camera 1 to the HubWay8Di/16Di unit utilizing CAT-5 or higher 
 

structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1] 

 

of the HubWay8Di/16Di (Fig. 1a, pg. 4). Plug the RJ45 connector at the opposite end of the structured 

 

cable into the RJ45 jack of the Video Balun/Combiner located at camera 1.

 

•  For 24VAC cameras use Altronix model HubWayAv/HubWayAv2 Video Balun/Combiner (Figs. 2a, 2b, 2e, pg. 5).

 

•  For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 5).

 

•  For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner (Figs. 2c, 2d, pg. 5).

 

Repeat steps 6-9 for each additional camera (Channels 2-8 or Channels 2-16).

 

Note: When a particular camera exceeds the maximum distance for power transmi  ssion, a local 

 

external power source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral 

 

Camera Power may be utilized (Fig. 4a, pg. 6). The combined total cable distance must not exceed 750 ft. for 

 

video transmission between the HubWay8Di/16Di and each camera routed through the HubSat4D.

10. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and measure the
 

output voltage at the power output of each Video Balun/Combiner (Figs. 2b, 2d, pg. 5) before powering each camera 

 

to ensure proper operation and avoid possible damage.

 

•  HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 2a, 2b, 2e, pg. 5).

 

•  HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 5)

11. Set illuminated master power disconnect circuit breaker to the (OFF) position to make the final 
 connections 

(Fig. 5, pg. 7).

12. Connect the power outputs of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to  
 

the power inputs of the cameras (Figs. 2a-2e, pg. 5). Polarity must be observed.

13. Connect the terminals marked [+ DATA -- ] of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video  

 

 

Balun/Combiners to the data terminals of the cameras for PTZ control (Figs. 2a-2e, pg. 5). Polarity must be observed.

 

When using fixed cameras disregard this step.

14. Connect the BNC connector of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners    
 

to the BNC video outputs of the cameras (Figs. 2a-2e, pg. 5).

15. Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position
 

(Fig. 5, pg. 7). 

16. The power LEDs (Red) located on the front of the HubWay8Di/16Di will illuminate when AC power 
 

is present (Fig. 1c, pg. 4).

 

Note: If any of these LEDs are not illuminated either a voltage output selector switch is in the OFF position or the 

 

PTC is tripped for that channel.

 

To reset the PTC:

 

1.  Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain

 

  in the OFF position for approximately 2 minutes in order for the PTC to reset.

 

2.  Eliminate the trouble condition (short circuit or overload).

 

3.  Set the voltage output selector switch for 24VAC or 28VAC (Fig. 1d, pg. 4).

17. AC LEDs (Green) of the HubWayAv or DC LEDs (Red) of the HubWayDv/HubWayDvi Video Balun/Combiners
 

will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 5). 

Содержание HubWay162Di

Страница 1: ...eiver Hub with Integral Isolated Camera Power Transceiver Hub with Integral Isolated Camera Power Includes eight 8 UL Listed Accessory Includes sixteen 16 UL Listed Accessory HubWayAv Video Balun Combiners HubWayAv Video Balun Combiners HubWay83Di HubWay163Di UL Listed eight 8 Channel Passive UTP UL Listed sixteen 16 Channel Passive UTP Transceiver Hub with Integral Isolated Camera Power Transceiv...

Страница 2: ...UL Listed Accessory HubWayAv Video Balun Combiners for 24VAC Cameras HubWay163Di HubWay16Di with sixteen 16 UL Listed Accessory HubWayDvVideo Balun Combiners for 12VDC Cameras Agency Listings UL Listed for Commercial CCTV Equipment UL 2044 CUL Listed CSA Standard C22 2 No 1 04 Audio Video and Similar Equipment Data RS422 RS485 data inputs Power Individually selectable 24VAC or 28VAC power outputs ...

Страница 3: ...e for power transmi ssion a local external power source is required Optionally an Altronix HubSat4D Passive UTP Transceiver Hub with Integral Camera Power may be utilized Fig 4a pg 6 The combined total cable distance must not exceed 750 ft for video transmission between the HubWay8Di 16Di and each camera routed through the HubSat4D 10 Set illuminated master power disconnect circuit breaker to the ...

Страница 4: ...o outputs to head end equipment DVR 1d Output voltage switches Selects 24VAC 28VAC OFF for each output 1b Channels 1 4 Channels 5 8 Channels 9 12 Channels 13 16 CAT 5 or higher structured cable from optional HubSat4D enables video transmission from up to four 4 cameras 1g IEC 320 Connector 115VAC 60Hz 230VAC 50 60Hz grounded line cord included Fig 1 1e Data Removable terminal blocks for RS422 RS48...

Страница 5: ...des and PIN Configurations HubWayAv HubWayAv2 passes AC voltage from pins 4 5 7 8 to terminals marked AC Power Fig 3 pg 5 HubWayDv HubWayDvi converts AC voltage to DC voltage from pins 4 5 7 8 to terminals marked 12VDC Fig 3 pg 5 VIDEO BALUN COMBINER CAT5 DATA POWER AC VIDEO HubWayAv VIDEO AC Power to Camera Data to Camera Data to Camera Green Power LED 12VDC Power to Camera Red Power LED Wire Con...

Страница 6: ... Camera HubWayDv Dvi Video Balun Combiner Video Data Power Video Data Power HubWayAv Video Balun Combiner HubWayAv Video Balun Combiner Max video 750 ft Video Power HubWayDv Dvi Video Balun Combiner CAT 5 24VAC 28VAC Camera Power Provided by HubSat4D Video Data Power Outdoor NEMA Rated Power Supply Outdoor PTZ Camera 115VAC Input 50 60Hz HubWayAv or HubWayDv Dvi Video Balun Combiner Monitor Rear F...

Страница 7: ... within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanyi...

Страница 8: ...en installing the unit vertically Rack Mount Installation 1 Remove and discard factory installed screws from both sides of rack chassis Fig 6a 2 Install mounting brackets A on the left and right side of rack chassis using the four 4 flat head screws B included Fig 6b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not included Fig 6c Fig 8 Fig 7 Shelf Installation 1 ...

Отзывы: