7. Plug the RJ45 connector at one end of the CAT-5 or higher structured cable into the RJ45 jack marked [PVD1] 

on Circuit Board A 

(Fig. 1i, pg. 4)

. Plug the RJ45 connector at the opposite end of the CAT-5 or higher structured 

cable into the RJ45 jack of the Video Balun/Combiner to be installed at camera 1.

For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner 

(Figs. 2a, 2b, pg. 6)

.

For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner 

(Figs. 2c, 2d, pg. 6)

.

For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner 

(Figs. 2c, 2d, pg. 6)

.

The total cable distance must not exceed 750 ft. for video transmission between the HubSat8D and each camera.
Repeat this step for all other camera channels [PVD2-4] on Circuit Board A and [PVD1-4] on Circuit Board B.

8. Set illuminated master power disconnect circuit breaker to the RESET (ON) position 

(Fig. 4a, pg. 6) 

power 

LEDs (Green) of the HubSat8D will illuminate when AC power is present 

(Fig. 1e, pg. 4) 

and HubWayAv, HubWayDv

or HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present 

(Fig. 2b, 2d, pg. 6).

9. Measure the output voltage at each Video Balun/Combiner 

(Figs. 2b, 2d, pg. 6)

before making connections to

each camera to insure proper operation and avoid possible damage.

10. Set illuminated master power disconnect circuit breaker to the (OFF) position 

(Fig. 4a, pg. 6)

.

11. Connect power outputs of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to power inputs

of cameras 

(Figs. 2a-2d, pg. 6). 

Polarity must be observed.

HubWayAv - Terminals marked [AC POWER] 

(Figs. 2a, 2b, pg. 6)

.

HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] 

(Figs. 2c, 2d, pg. 6)

.

12. Connect the terminals marked [+ DATA -- ] of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners 

to data input terminals of cameras for PTZ control 

(Figs. 2b-2d, pg. 6)

. Polarity must be observed

.

When using fixed cameras disregard this step.

13. Connect the BNC connector of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the 

BNC video outputs of cameras 

(Figs. 2b-2d, pg. 6)

.

14. Set illuminated master power disconnect circuit breaker to the RESET (ON) position 

(Fig. 4a, pg. 6).

15. The power LEDs (Green) of the HubSat8D will illuminate when AC power is present 

(Fig. 1e, pg. 4).

Note:

If any of the power LEDs are not illuminated the cause may be due to the following:

a.

AC mains fail.

b.

Illuminated master power disconnect circuit breaker is tripped.

c.

One or both primary in-line fuse(s) are blown.

Note: Replace fuse with same type and rating:

Primary in-line fuses are rated @ 3.5A/250V 

(Fig. 4b, pg. 6)

.

d. An individual power output voltage switch is set to the OFF position 

(Fig. 1d, pg. 4)

.

e.

A PTC is tripped due to a short circuit or overload condition for one or more channels/power outputs.
To reset the PTC:
1.

Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must 
remain in the OFF position for approximately 2 minutes in order for the PTC to reset 

(Fig. 1d, pg. 4)

.

2.

Eliminate the trouble condition (short circuit or overload).

3.

Set the voltage output selector switch for either 24VAC or 28VAC 

(Fig. 1d, pg. 4)

.

HubSat8D for use as a Remote Accessory Module with HubWay/HubWayLD/HubWayLDH UTP Transceiver Hubs.

After completing steps 1-4 of Installation Instructions HubSat8D Passive UTP Transceiver Hub with Integral Camera
Power. proceed with the following.
1. For fixed cameras run two (2) CAT-5 cables between HubSat8D and HubWay, HubWayLD or HubWayLDH to allow

video transmission of up to eight (8) cameras. For PTZs run three (3) CAT-5 cables between HubSat8D and
HubWay, HubWayLD or HubWayLDH 

(Fig. 6, pg. 7)

.

a.

Connect one (1) of the CAT-5 cables to the RJ45 jack marked [Video 1-4] on Circuit Board A. Connect the
opposite end of this CAT-5 cable into the RJ45 jack marked [CH 1-4] of HubWay, HubWayLD or
HubWayLDH unit 

(Fig. 6, pg. 7)

.

b.

Connect the second CAT-5 cable to the RJ45 jack marked [Video 1-4] on Circuit Board B. Connect the
opposite end of this CAT-5 cable into the RJ45 jack marked [CH 5-8] of HubWay, HubWayLD or
HubWayLDH unit 

(Fig. 6, pg. 7)

.

c.

For data (PTZ) connect the third CAT-5 cable to the RJ45 jack marked [Data 1-4] on Circuit Board A. Connect 
the opposite end of this CAT-5 cable into any unused RJ45 jack marked [1-16] of HubWay, HubWayLD or
HubWayLDH unit 

(Fig. 6, pg. 7)

.

Note:

Data inputs of HubWay, HubWayLD or HubWayLDH units must be wired in parallel for proper operation.

When using fixed cameras disregard this step.

Primary
In-line Fuse

Содержание HubSat8D

Страница 1: ...hannel Passive UTP Transceiver Hub with Integral Camera Power HubSat82D Eight 8 Channel Passive UTP Transceiver includes eight 8 HubWayAv Video Balun Combiners HubSat83D Eight 8 Channel Passive UTP Transceiver includes eight 8 HubWayDv Video Balun Combiners Rev 112508 More than just power TM Video Data Power ...

Страница 2: ...at82D HubSat8D with eight 8 HubWayAv Video Balun Combiners for 24VAC Cameras HubSat83D HubSat8D with eight 8 HubWayDv Video Balun Combiners for 12VDC Cameras WARNING To reduce the risk of fire or electric shock do not expose the unit to rain or moisture This installation should be made by qualified service personnel and should conform to all local codes Installation Instructions HubSat8D Passive U...

Страница 3: ...pg 6 15 The power LEDs Green of the HubSat8D will illuminate when AC power is present Fig 1e pg 4 Note If any of the power LEDs are not illuminated the cause may be due to the following a AC mains fail b Illuminated master power disconnect circuit breaker is tripped c One or both primary in line fuse s are blown Note Replace fuse with same type and rating Primary in line fuses are rated 3 5A 250V ...

Страница 4: ...s of HubWayAv HubWayDv or HubWayDvi Video Balun Combiners to power inputs of cameras Figs 2a 2d pg 6 Polarity must be observed HubWayAv Terminals marked AC POWER Figs 2a 2b pg 6 HubWayDv HubWayDvi Terminals marked 12VDC Figs 2c 2d pg 6 7 Connect the terminals marked DATA of HubWayAv HubWayDv or HubWayDvi Video Balun Combiners to data input terminals of cameras for PTZ control Figs 2b 2d pg 6 Polar...

Страница 5: ...Remote Accessory Module for use with HubWay HubWayLD or HubWayLDH UTP Transceiver Hubs proceed with the following 1 Set illuminated master power disconnect circuit breaker to the OFF position Fig 4a pg 6 2 Connect one end of the coaxial cable to the BNC connector marked Video1 on Circuit Board A Fig 1a pg 4 Connect the opposite end of the coaxial cable to the BNC video output of camera 1 Fig 6a pg...

Страница 6: ...erts AC voltage to DC voltage through pins 4 5 7 8 and 12VDC terminals 115VAC input 60 Hz White Lead Green Lead ground XFMR Black Lead Wire Strap from Enclosure to Door XFMR Primary In line Fuse non power limited PVD1 VIDEO1 VIDEO2 VIDEO3 VIDEO4 PVD2 PVD3 PVD4 DATA DATA 1 4 VIDEO 1 4 28VAC 24VAC 28VAC 24VAC 28VAC 24VAC 28VAC 24VAC OFF OFF OFF OFF AUX1 AUX2 BK 24 YL 0 Br AUX3 AUX4 non power limited...

Страница 7: ...Video Data Power Video Data Power 12VDC PTZ Camera Coax Power 12VDC Fixed Camera Coax Power HubWayD Video Balun Combiner Video Data Power 12VDC PTZ Camera 24VAC Fixed Camera Coax Power 24VAC Fixed Camera Coax Power 24VAC Fixed Camera Fig 6 Typical Application Drawing HubSat8D Passive UTP Transceiver Hub with Integral Camera Power 115VAC Input 60Hz Head End Equipment DVR RS485 BNC Data Video Power ...

Страница 8: ...s 13 5 H x 13 W x 3 25 D The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating a...

Отзывы: