- 2 -
eBridge1STR
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and
with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or
Recognized wire suitable for the application.
eBridge1ST and eBridge1PCRM are not intended to be connected to outside plant leads and
should be installed indoors within protected premises. eBridge1ST and eBridge1PCRM are
intended for indoor use only.
Note: The eBridge1PCRM and eBridge1ST are a paired set and must be used together.
1. eBridge1PCRM installation:
a. Secure unit to the desired mounting surface with a proper fastening device utilizing the
unit’s mounting hole (Fig. 2a, pg. 3). Unit should be mounted in the proximity to ethernet
switch/network, NVR or video server.
Note: When installing more than one (1) eBridge1PCRM, please allow at least 1” (25mm)
distance between the receivers.
b. Connect structured cable from Ethernet midspan or endspan device to RJ45 jack marked
[PoE
Input]
(Fig. 2, pg. 3).
c. Connect Coax cable to the BNC connector marked [Coax] (Fig. 2, pg. 3).
2. eBridge1ST installation:
a. Secure unit to the desired mounting surface with a proper fastening device utilizing the case’s
mounting
hole
(Fig. 2a, pg. 3). Unit should be mounted in the proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out] (Fig. 2, pg. 3).
c. Connect Coax cable to the BNC tether cable marked [Coax] (Fig. 2, pg. 3).
Note: This kit is designed to accommodate Megapixel and non-Megapixel cameras.
It is important to note that some high resolution and high frame rate cameras may demand faster
headend processing ability, such as a PC graphics card, to present a quality image. If the headend
processing equipment’s speed is insufficient, the image may show pixelation and latency. It is
advisable to pretest system if unsure. Alternatively, frame rate and resolution may be reduced to
accommodate system equipment.
Technical Specifications:
Parameter
Description
Connections
BNC for Coax link.
Input power
requirements
Midspan or endspan port connected. PoE compliant to IEEE 802.3af (15W)
and PoE+ compliant to IEEE 802.3at (30W).
Indicators
Yellow (RJ45 connector): On - Link, Off - No Link, Blinking - Activity.
Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T.
Green: PoE Active.
Blue (eBridge1ST): Coax Link is active.
Environmental
Conditions
Operating Ambient Temperature: UL60950-1
eBridge1PCRM:
-20ºC to 49ºC (-4ºF to 120.2ºF).
eBridge1ST: For 15W: -40ºC to 75ºC (-40ºF to 167ºF).
For 30W: -40ºC to 65ºC (-40ºF to 149ºF).
Relative humidity:
85%, +/- 5%.
Storage Temperature: -40ºC to 75ºC (-40ºF to 167ºF).
Operating Altitude:
-304.8 to 2,000m.
Regulatory
Compliance
UL/cUL Listed for Information Technology Equipment (UL 60950-1).
CE approved.
Weights (approx.) Product: 0.4 lbs. (0.18kg) | Shipping: 1 lbs. (0.45kg).