Overview:

Altronix ALTV2432UL Series CCTV Power Supplies provide 24VAC or 28VAC distributed via thirty-two (32) fuse or 

PTC protected outputs for powering CCTV cameras, heaters and other video accessories.

Thirty-Two (32) Output ALTV2432UL Reference Chart:

Altronix 

Model Number

Output Voltage

Total 

 Output Current 

(Power)

Number of Outputs

PTC Protected auto- resettable Outputs  (Class 2 Rated power-  imited for Dry locations,  Class 3 for Wet locations)

Fuse Protected  Class 1 Outputs

Individual Output Current (max per output, not to exceed total output current)

Fuse Ratings

115VAC 60Hz Input Current

Agency Listings

ALTV2432300UL

24VAC 12.5A

32

P

3.5A

3.5A 2.7A

28VAC 10A

ALTV2432300ULCB

24VAC 12.5A

32

P

2.5A

2.7A

28VAC 10A

ALTV2432600UL

24VAC 25A

32

P

3.5A

3.5A 5.4A

28VAC 20A

ALTV2432600ULCB

24VAC 25A

32

P

2.5A

5.4A

28VAC 20A

Specifications:

Agency Listings:

•  UL Listed for Commercial CCTV Equipment (UL 2044). 

  CUL Listed - CSA Standard C22.2 No.1-98, 

  Audio, Video and Similar Equipment. 

•  CE European Conformity.

Input:

•  115VAC, 50/60Hz.

Output:

•  Thirty-two (32) fuse or PTC protected outputs. 

•  24VAC or 28VAC output

•  Outputs are rated @ 3.5A (fused) or 2.5A (PTC).

•  Surge suppression.

Features:

•  AC power LED indicator.

•  Illuminated power disconnect circuit breaker 

  with  manual  reset.    

•  Unit maintains camera synchronization.

•  Ease of installation saves time and eliminates 

  costly labor.

•  Spare fuses included (on fuse protected models).

Enclosure Dimensions 

(H x W x D)

:

  13.5” x 13” x 3.25”

  (342.9mm x 330.2mm x 82.6mm).

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all 

local codes and authorities having jurisdiction. Product is intended for indoor use only. 

1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes 

  in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place 

  the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower 

  two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s 

  upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws 

 

(Enclosure Dimensions, pg. 8)

. Secure enclosure to earth ground.

2. Turn OFF main switch on the unit 

(Fig. 1 - 2, pg. 4 - 5)

.

3. All units are factory set for 24VAC operation. 

  For 28VAC operation adjust unit prior to mounting and applying power as follows: 

  Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and 

  the yellow wire [24V] is connected to the terminal marked [S]

.

4. Connect AC power to the black and white flying leads of the transformer(s) 

(Fig. 1 - 2, pg. 4 - 5)

, secure 

  green lead to earth ground. Use 18 AWG or larger for all power connections.

Содержание ALTV2432UL Series

Страница 1: ...VAC 10A 280VA Thirty two 32 PTC Protected Outputs ALTV2432600ULCB 24VAC 25A 600VA or 28VAC 20A 560VA Thirty two 32 PTC Protected Outputs ALTV2432UL Series CCTV Power Supplies Models Include Rev 040506...

Страница 2: ...ronization Ease of installation saves time and eliminates costly labor Spare fuses included on fuse protected models Enclosure Dimensions H x W x D 13 5 x 13 x 3 25 342 9mm x 330 2mm x 82 6mm Installa...

Страница 3: ...reduce the risk of fire or electric shock do not expose the unit to rain or moisture This installation should be made by qualified service personnel and should conform to the National Electrical Code...

Страница 4: ...COMMON 11 10 9 12 13 P 16 15 14 N 3 5A 250V N XFMR INPUT S P P N 3 1 2 4 5 6 7 8 PROTECTED OUTPUTS OUTPUTS COMMON 11 10 9 12 13 P 16 15 14 N 3 5A 250V N XFMR INPUT S P P N 3 1 2 4 5 6 7 8 PROTECTED OU...

Страница 5: ...power limited N XFMR INPUT S P P N 3 1 2 4 5 6 7 8 PROTECTED OUTPUTS OUTPUTS COMMON 11 10 9 12 13 P 16 15 14 N 3 5A 250V N XFMR INPUT S P P N 3 1 2 4 5 6 7 8 PROTECTED OUTPUTS OUTPUTS COMMON 11 10 9...

Страница 6: ...6 ALTV2432UL Series Installation Guide Notes...

Страница 7: ...ALTV2432UL Series Installation Guide 7 Notes...

Страница 8: ...1 20 30 5mm 0 9375 23 8mm 0 9375 23 8mm 5 10 129 5mm 1 40 35 6mm 5 10 129 5mm 6 5625 166 7mm 3 25 82 6mm 3 25 82 6mm 3 25 82 6mm 10 5 266 7mm 1 0 25 4mm 1 0 25 4mm 1 0 25 4mm 13 0 330 2mm 5 10 129 5m...

Отзывы: