42 ULADA Application Guide

R1042ULADA Enclosure Dimensions 

(H x W x D)

:

3.25” x 19.0” x 26.5” (82.6mm x 482.6mm x 673.1mm). Shown with Z Bracket attached.

3.25”

82.3mm

26.5”

673.1mm

19” (482.6mm)

2.4”

61mm

4.57”

116.1mm

11.175” (283.8mm)

R 1.27” (32.3mm)

1” (25.4mm)

0.55” (14mm)

3.62”

92mm

0.1”

2.5mm

1.5”

38.1mm

Altronix is not responsible for any typographical errors.

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty 

42ULADA Application Guide 

H09U

MEMBER

Содержание AL1042ULADA

Страница 1: ...er Extenders R1042ULADA Rack Mountable NAC Power Extender Application Guide see Installation Guide for additional information Rev 062420 More than just power TM Installing Company ________________ Service Rep Name ___________________________________ Address ______________________________________________ Phone ___________________ ...

Страница 2: ...lass B Hookups Each output 1 through 4 can be used in Class B or Class A configuration For Class A hookups loop starts on OUT 1 through 4 terminates on corresponding RET For Class B hookups loop starts on OUT terminates on 2 2K EOL Altronix Model AL EOL22 AUX1 OUT4 OUT3 OUT2 OUT1 AUX2 LOOP4 LOOP3 LOOP2 LOOP1 RET1 IN1 IN2 RET2 NO DRY2 C NO DRY1 C From FACP NAC1 2 2K EOL 2 2K EOL From FACP NAC2 To F...

Страница 3: ... of NAC Power Extenders Applications that do not employ synchronization module or FACP with synchronization protocol will not provide NAC synchronization between NAC Power Extenders 3 Non synchronizable NAC Appliances When using NAC appliances not designed to support synchronization feature it is recommended to use separate output circuits for audible notification appliances horns and visual notif...

Страница 4: ...s Fig 5a For continuous loop circuit use 2 2K EOL Altronix Model AL EOL22 NAC Power Extender DIP Switches set for desired Sync Protocol ex Gentex System Sensor Amseco CooperWheelock FACP Fire Alarm Control Panel 2 2K EOL 2 2K EOL 2 2K EOL AUX1 OUT1 LOOP1 LOOP2 OUT2 OUT3 LOOP3 LOOP4 OUT4 RET1 IN1 RET2 IN2 C DRY2 NC C DRY1 NC AUX1 EOL or Next Device For Class A configuration return to FACP EOL or Ne...

Страница 5: ...nect both Input 1 and Input 2 to it Wire RET1 and RET1 to INP2 and INP2 Both Visual and Audible appliances will be activated simultaneously Fig 6a EOL or Next Device For Class A configuration return to FACP FACP RET2 IN2 RET1 IN1 C DRY1 NC C DRY2 NC Control Circuit No Notification Appliances Allowed Fig 6a ...

Страница 6: ...the flash timing of the strobe allowing audible notification appliances horns and visual notification appliances strobes to be silenced deactivated at the same time Gentex Sync Mode Gentex is a registered trademark of Gentex Corporation 1 2 3 4 This mode is designed to work with the Gentex series of horns strobes and horn strobes to provide a means of synchronizing the Temporal coded horns synchro...

Страница 7: ... 1mm 2 5 63 5mm 1 0 25 4mm 2 75 69 9mm 2 75 69 9mm 4 5 114 3mm 4 5 114 3mm 14 5 368 3mm 1 0 25 4mm 1 5 38 1mm 8 5 215 9mm 18 0 457 2mm 18 0 457 2mm 18 0 457 2mm 1 25 31 75mm 1 25 31 75mm 1 5 38 1mm 1 5 38 1mm 1 5 38 1mm 1 5 38 1mm 2 5 63 5mm 2 5 63 5mm 14 5 368 3mm 14 5 368 3mm 4 5 114 3mm 1 0 25 4mm 1 0 25 4mm 1 0 25 4mm 1 0 25 4mm ...

Страница 8: ...5 673 1mm 19 482 6mm 2 4 61mm 4 57 116 1mm 11 175 283 8mm R 1 27 32 3mm 1 25 4mm 0 55 14mm 3 62 92mm 0 1 2 5mm 1 5 38 1mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty 42ULADA Application Guide H09U MEMBER ...

Отзывы: