M Series

Multi-Output Access Control
Power Supply Chargers

Installation Guide

Models Include:

AL300ULM

AL400ULM

-

2.5 amp @ 12VDC or 24VDC.

-

3 amp @ 12VDC 

or 4 amp @ 24VDC.

AL600ULM

AL1012ULM

-

6 amp @ 12VDC or 24VDC.

10 amp @ 12VDC.

AL1024ULM

10 amp @ 24VDC.

Rev. 111103

For a red enclosure, add an “R” suffix to the part # e.g. AL300ULMR

 

 

 

 

 

 

 

  

  

 

 

Содержание AL1012ULM

Страница 1: ...gers Installation Guide Models Include AL300ULM AL400ULM 2 5 amp 12VDC or 24VDC 3 amp 12VDC or 4 amp 24VDC AL600ULM AL1012ULM 6 amp 12VDC or 24VDC 10 amp 12VDC AL1024ULM 10 amp 24VDC Rev 111103 For a red enclosure add an R suffix to the part e g AL300ULMR ...

Страница 2: ...AL1012ULXB Power Supply Board maximum charge current 7 amp AL1024ULXB Power Supply Board maximum charge current 3 6 amp Zero voltage drop when switching over to battery backup AL300ULM AL400ULM and AL600ULM enclosures accommodate up to two 2 12VDC 7AH batteries AL1012ULM should be fitted with one 1 12VDC 12AH battery AL1024ULM enclosure accommodates up to two 2 12VDC 12AH batteries AL300ULM 2 5 2 ...

Страница 3: ...dware e g door strikes and electronic dead bolts positive leads to terminals marked 1 through 5 POS DC OUTPUT ALARM on MOM5 board and the negative leads to terminals marked NEG 1 through NEG 5 on MOM5 board Fig 1 pg 5 Fig 2 pg 6 Fig 3 pg 7 Fig 4 pg 8 6 Connect Fail Safe type locking hardware e g mag locks door strikes and door holders positive leads to terminals marked 6 through 10 POS DC OUTPUT S...

Страница 4: ...L400ULM Output Switch 4 hr of Stand by 24 hr of Stand by 60 hr of Stand by Position 5 Minutes of Alarm 5 Minutes of Alarm 5 Minutes of Alarm 12VDC 40 AH Battery Closed Stand by 4 0 amp Stand by 1 0 amp Stand by 300mA Alarm 4 0 amp Alarm 4 0 amp Alarm 4 0 amp 24VDC 12 AH Battery Open Stand by 200mA Alarm 3 0 amp 24VDC 40 AH Battery Open Stand by 3 0 amp Stand by 1 0 amp Stand by 300mA Alarm 3 0 amp...

Страница 5: ...115VAC power mains non power limited Class 1 Divider NC C NO DRY OUTPUT TRIGGER LED 6 7 8 9 10 POS DC OUTPUT STANDBY NC C NO POWER FAIL TRIGGER 1 2 3 4 5 POS DC OUTPUT ALARM NEG1 NEG2 NEG3 NEG4 NEG5 DC INPUT NEG INPUT POS DC Outputs to devices power limited Fire Alarm Interface non power limited CAUTION De energize unit prior to servicing For continued protection against risk of electric shock and...

Страница 6: ...ion against risk of electric shock and fire hazard replace fuses with the same type and rating see marking on the board Replace fuse cover before energizing Do not expose to rain or moisture Power Limited NC C NO NC C NO AC FAIL BAT FAIL Battery AC Supervision Circuit power limited DC BAT FAIL NC C NO NC C NO BAT DC 24V OPEN 12V CLOSED SW1 AC FAIL L G N AC AC Delay Switch Detail OPEN SWITCH CLOSED...

Страница 7: ...puts to devices power limited NC C NO NC C NO CAUTION De energize unit prior to servicing For continued protection against risk of electric shock and fire hazard replace fuses with the same type and rating see marking on the board Replace fuse cover before energizing Do not expose to rain or moisture 12VDC Rechargeable Battery optional Keep power limited wiring separate from non power limited Use ...

Страница 8: ...ower limited NO C NC NO C NC CAUTION De energize unit prior to servicing For continued protection against risk of electric shock and fire hazard replace fuses with the same type and rating see marking on the board Replace fuse cover before energizing Do not expose to rain or moisture 12VDC Rechargeable Battery optional 12VDC Rechargeable Battery optional Keep power limited wiring separate from non...

Страница 9: ...wer OFF ON No DC output Short circuit or thermal overload condition OFF OFF No DC output Loss of AC Discharged battery MOM5 Output Module LED ON OFF Power Green Normal operation Power failure Trigger Green Input is triggered alarm condition No input trigger non alarm condition Outputs Red Output tripped due to a Normal operation short circuit or overload condition ...

Страница 10: ...024ULXB Power Supply Board maximum charge current is 3 6 amp MOM5 Output Module Terminal Legend Function Description DC INPUT 12VDC or 24VDC from power supply TRIGGER Dry normally open NO or normally closed NC supervised 2 2K EOL resistor input trigger A short or open circuit will transfer power from terminals marked POS DC OUTPUT STAND BY to terminals marked POS DC OUTPUT ALARM INPUT Wet 5 30VDC ...

Страница 11: ...ts Non Latching Fig 5 Typical Application Diagrams TRIGGER NEG INPUT POS EOL 2 2K DC VOLTAGE INPUT FROM FACP SIGNALING OUTPUT OR ACCESS CONTROL DEVICE N C INPUT FROM FACP OR ACCESS CONTROL DEVICE TRIGGER NEG INPUT POS EOL 2 2K DC VOLTAGE INPUT FROM FACP SIGNALING OUTPUT OR ACCESS CONTROL DEVICE N O INPUT FROM FACP OR ACCESS CONTROL DEVICE MOM5 module shown with wet and or dry nor mally closed trig...

Страница 12: ...N O INPUT FROM FACP NC C NO DRY OUTPUT NC C NO POWER FAIL NC C NO DRY OUTPUT NC C NO POWER FAIL Fig 10 Two 2 MOM5 modules shown with wet and or dry normally open fire alarm trigger inputs Latching with Manual Reset Fig 8 TRIGGER LED TRIGGER NEG INPUT POS POWER ON LED N C RESET EOL 2 2K DC VOLTAGE INPUT FROM FACP SIGNALING OUTPUT N O INPUT FROM FACP SIGNALING OUTPUT NC C NO DRY OUTPUT NC C NO POWER...

Страница 13: ...25 3 25 5 10 5 10 3 25 1 00 10 50 1 00 1 00 1 00 1 40 1 20 1 40 1 20 0 75 0 75 11 00 12 50 3 25 0 9375 0 9375 1 40 4 85 4 85 1 40 1 20 Bottom Top Right Left Enclosure Dimensions AL300ULM AL400ULM AL600ULM 13 5 H x 13 W x 3 25 D ...

Страница 14: ... 14 Mseries 1 285 1 285 Enclosure Dimensions AL1012ULM AL1024ULM 15 5 H x 12 W x 4 5 D ...

Страница 15: ...Mseries 15 Notes ...

Страница 16: ...h Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIMseries G11G MEMBER Altronix is not responsible for any typographical errors Notes ...