Altronix AL100UL Скачать руководство пользователя страница 3

AL100UL

- 3 -

Terminal Identification:

Terminal

Function/Description

Legend

AC/AC

Low voltage AC input (16.5VAC/20VA). UL Listed. Class 2 plug-in transformer.

– DC +

12VDC @ .75 amp continuous power limited output. 

– BAT +

Stand-by battery connections. Maximum charge rate 500mA.

AC FAIL

Indicates loss of AC, e.g connect audible device or alarm panel. Relay is normally 

NC, C, NO

energized when AC power is present. Contact rating 1 amp @ 28VDC.

LOW BAT

Indicates low battery condition e.g connect audible device or alarm panel. Relay is 

NC, C, NO

normally energized. Contact rating 1 amp @ 28VDC.

Содержание AL100UL

Страница 1: ... When batteries are not used a loss of AC will result in the loss of output voltage When the use of stand by batteries are desired they must be lead acid or gel type Maintenance Unit should be tested at least once a year for the proper operation as follows Output Voltage Test Under normal load conditions the DC output voltage should be checked for proper voltage level see power supply voltage outp...

Страница 2: ... DC output OFF OFF Loss of AC Discharged or no stand by battery No DC output Stand by Specifications Using 1 4AH 12VDC Battery Current Draw Stand by Time Alarm Time 750mA 4 hours 15 mins AC DC AC FAIL LOW BAT RL2 RL1 PTC1 IC1 C1 NO C NC NO C NC 16 5VAC 20VA Plug in Transformer UL Listed Class 2 Transformer 750mA 12VDC Power Limited Output Stand by Battery ...

Страница 3: ...er limited output BAT Stand by battery connections Maximum charge rate 500mA AC FAIL Indicates loss of AC e g connect audible device or alarm panel Relay is normally NC C NO energized when AC power is present Contact rating 1 amp 28VDC LOW BAT Indicates low battery condition e g connect audible device or alarm panel Relay is NC C NO normally energized Contact rating 1 amp 28VDC ...

Страница 4: ... 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIAL100UL G29I MEMBER Enclosure Dimensions 8 5 H x 7 5 W x 3 5 D Altronix is not responsible for any typographical errors ...