ACM8E/ACM8CBE
Overview:
These units convert one (1) 12 to 24 volt AC or DC input into eight (8) independently controlled fused or PTC
protected outputs. These power outputs can be converted to dry form “C” contacts (ACM8E only). Outputs are
activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card
Reader, Keypad, Push Button, PIR, etc. The units will route power to a variety of access control hardware devices
including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or
Fail-Secure modes. Units are designed to be powered by one common power source which will provide power
for both the board operation and locking devices, or two (2) totally independent power sources, one (1) provid-
ing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency
Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature
is individually selectable for any or all of the eight (8) outputs.
ACM8E and ACM8CBE Series Configuration Reference Chart:
Altronix
Model
Number
Fuse Protected
Outputs
PTC Protected
Auto-Resettable
Outputs
Output Ratings
Class 2 Rated
Power- Limited
Agency Listing
UL Listings and File Numbers
ACM8E
P
------------
3.5A
*
UL 294
(File # BP6714)
UL Listed for Access Control System
Units.
“Signal Equipment” Evaluated to CSA
Standard C22.2
No.205-M1983
ACM8CBE
------------
P
2.5A
P
*When used with Class 2 Rated Power-Limited power supply.
Specifications:
• 12 to 24volt AC or DC operation (setting not required).
(0.6A @ 12 volt, 0.3A @ 24 volt current consumption with all relays energized).
• Power supply input options:
a) One (1) common power input (board and lock power).
b) Two (2) isolated power inputs (one (1) for board power and one (1) for lock/hardware power).
• Eight (8) Access Control System trigger inputs:
a) Eight (8) normally open (NO) inputs.
b) Eight (8) open collector sink inputs.
c) Any combination of the above.
• Eight (8) independently controlled outputs:
a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
b) Eight (8) dry form “C” 5A rated relay outputs (ACM8E only).
c) Any combination of the above (ACM8E only).
• Eight (8) auxiliary power outputs (unswitched).
• Output ratings:
- Fuses are rated 3.5A each.
- PTCs are rated 2.5A each.
• Main fuse is rated at 10A.
Note: Total output current is determined by the power supply, not to exceed a maximum of 10A total.
• Red LEDs indicate outputs are triggered (relays energized).
• Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input.
b) Polarity reversal input from FACP signaling circuit.
• FACP output relay (form “C” contact rated @ 1A 28VDC, not evaluated by UL).
• Green LED indicates when FACP disconnect is triggered.
• Removable terminal blocks facilitate ease of installation.
Enclosure Dimentions (H x W x D): 15.5” x 12” x 4.5” (393.7mm x 304.8mm x 114.3mm).
Altronix Corp.
140 58th St. Brooklyn, NY