Redback A 2067 Line Monitoring Unit

Page 2

BL1564

Remote Fault Monitor

Refer to Instructions for Connections

16VAC

Input

24VDC

Input

+

-

Made In Australia by Altronic Distributors Pty Ltd

Out

10

In

10

Out

9

In

9

Out

8

In

8

Out

7

In

7

Out

6

In

6

In

5

Out

4

In

4

Out

3

In

3

Out

2

In

2

Out

1

In

1

Out

5

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

Zone 1

Zone 2

Zone 3

Zone 4

Zone 5

Zone 6

Zone 7

Zone 8

Zone 9

Zone 10

Open

Short

Good

Open

Short

Good

Cancel

On

Power

REDBACK

A 2067

Line Monitoring Unit

5

Fig 1. Rear Panel Legend

1

16V AC Input

2

24V DC Input

3

Remote fault connector (DB25)

4

Card 2 (Zones 6 - 10)

5

Card 1 (Zones 1 - 5)

Figure 1: A 2067 rear panel

4

3

2

1

Fig 2. Front Panel Legend

1

Zone Indicators 1-10

2

Piezo Buzzer

3

Cancel Button

4

Power Led

5

Power Switch

1

2

3

4

5

Figure 2: A 2067 front panel

Remote Fault Monitoring

A DB25 connector is provided to remote monitor line conditions.

These pins when in “good” condition are 12V. Once a circuit

becomes “open”or “short” the voltage switches to 0V or ground

Pin Number

Function

1

Open Zone 10

2

Open Zone 9

3

Open Zone 8

4

Open Zone 7

5

Open Zone 6

6

Open Zone 5

7

Open Zone 4

8

Open Zone 3

9

Open Zone 2

10

Open Zone 1

11

+12V

12

Ground

Pin Number

Function

13

Ground

14

Short Zone 10

15

Short Zone 9

16

Short Zone 8

17

Short Zone 7

18

Short Zone 6

19

Short Zone 5

20

Short Zone 4

21

Short Zone 3

22

Short Zone 2

23

Short Zone 1

24

+12V

25

Ground

Out

+

In

+

+

-

+

-

+

-

Fig. 3 Connection Details

Max Load, 100W per zone. Unused zones  must have 100k 0.25W 

end of line resistor installed. Max wire run, 200m.

Amplifier

22uf capacitors

100K 0.25W end
of line resistor.

Pin

1

2

3

4

5

6

7

8

9

10

14

15

16

17

18

19

20

21

22

23

+ve Pin 11,24

Pins 12, 13 and 25 are ground

Zone

10

9

8

7

6

5

4

3

2

1

10

9

8

7

6

5

4

3

2

1

Open Circuit

Contacts

Short Circuit

Contacts

Fig. 4 Common Fault Detection

If required the unit can be set up to trigger a relay contact whenever

ANY zone fault occurs eg, Whenever any zone from 1-10 becomes

OPEN or SHORT. Further problem diagnosis can then be determined

from the front panel as required. 