RESET/REBOOT SYSTEM 

 

If for any reason system locks up or will not respond you can try to 
reboot the system. 

 

1)

 

Remove unit from rubber boot. 

2)

 

Remove two screws that hold on bottom cover 

3)

 

Remove jumper to reset.  

4)

 

Wait one minute 

5)

 

Reinstall jumper 

6)

 

System should reboot 

Unit will not loose data by reset/reboot.  If unit does not function 
correctly after reset contact Tech Support. 

 

ABBREVIATIONS 

Temp Temperature degrees Fahrenheit 
Hum Relative 

Humidity 

Press Barometric Pressure Inches of Mercury 
DA Density 

Altitude

 

OA Oxygen 

Altitude 

DP 

Dew Point degrees Fahrenheit 

VP 

Vapor Pressure (inHG) inches of Mercury 

GOW Grains of Water  grains per pound 
ET Elapsed 

Time 

TS Throttle 

Stop 

SLET Sea Level ET 
ALT/
ET 

Ratio: change in ET for every 100’ change in Altitude 

TSR  Throttle Stop Ratio

 

ADR  Air Density Ratio 
CF 

Horse Power Correction Factor 

Содержание PerformAire Eclipse

Страница 1: ...Air Quality Computer U S PATENT 5 509 295 Invented and Manufactured By 1411 S Roselle Rd Schaumburg IL 60193 847 923 0002 847 923 0004 Fax www AltronicsInc com...

Страница 2: ...D PREDICTION ____________________________ 15 RUN ENTRY __ 16 SEA LEVEL ET 16 THROTTLE STOP RATIO 16 WEATHER ON HOLD 16 VIEWING DELETING RUNS 16 RUN COMPLETION 17 MAKING PREDICTIONS 18 DOWNLOADING TO A...

Страница 3: ...bases Sea level ET calculation Throttle stop ratio calculation ET to DA Ratio ET prediction Throttle stop prediction EZ PLATE prediction One run prediction Wind effect prediction Run completion Bad Ru...

Страница 4: ...f the unit Data base prediction mode prediction type and wind effect TAKING AIR SAMPLES 1 Place PerformBJSF in an area that will constantly expose it to the air you will be racing in out side of trail...

Страница 5: ...ecause of this we suggest using the following method until enough data has been acquired or using the One Run Prediction Method See Page 11 Gasoline burning engines A 200 rise in DA typically yields a...

Страница 6: ...tically if no keys are pressed for 1 minute ENTER HOLD key must be pressed after keying in a value to confirm the value is correct When pressed in SAMPLE AIR mode the air sample is held in memory and...

Страница 7: ...utton to exit wind readings and save wind values The saved wind values can be used when storing runs or correcting wind effects when predicting Saved wind values will automatically be displayed at app...

Страница 8: ...he CURRENT or the HELD data when entering or predicting data If the unit has been set to Auto Stable from the SAMPLE METHOD menu the following will be displayed when SAMPLE AIR is selected Stabilizing...

Страница 9: ...TE Barometric Pressure The Pressure reading is Absolute which means it will NOT agree with the weather channel or local forecast This is due to the fact that the local forecast is gives a corrected pr...

Страница 10: ...Data Base Pressing 1 displays the following screen and prompts the user to select one of the 10 available data bases Select Data Base Yes 1 No 2 After selecting a data base you will be asked if you w...

Страница 11: ...pressing 2 sets the unit to the TS MODE Throttle Stop Mode This means all runs added to the data base will be stored in the TS section and the PREDICTION will be a TS or timer setting computed from t...

Страница 12: ...Your base run data should be taken from a good run or your last good run You can update this data as you wish Enter Base Run DA ET Timer if in TS mode Temperature if fuel type Alcohol Humidity if fue...

Страница 13: ...ariable to reference your prediction against DA is suggested Wind Prediction If you have chosen Multiple Run Prediction you will be prompted to select to use wind correction into you ET or TS predicti...

Страница 14: ...nit to the JET MODE The jet program is based on the atmospheric calculation of Air Density Ratio ADR When the unit is SET UP in Jet Mode the ADR will be displayed in alternating fashion with the Densi...

Страница 15: ...ET SIZE XXX X EZ PLATE MODE By pressing 4 sets the unit to the PLATE MODE PLATE MODE Index 9 90 CHANGE YES 1 NO 2 If the user presses 1 the following will be displayed ENTER INDEX Now the user can ent...

Страница 16: ...cle type Select Car Type Dragster 1 Door 2 Roadster 3 Next you can adjust the wind effect Adjust Effect Press 1 Y 2 N Wind factors have been programmed to correct prediction for wind based on speed an...

Страница 17: ...100 of altitude change By pressing 1 you can view or delete runs you have already stored Use the SCROLL key to view runs If you want to delete a run you have scrolled to press the CLEAR key By pressi...

Страница 18: ...only be entered if the unit is in PLATE MODE Each plate is identified by a letter followed by a number First you will choose the letter To change the letter scroll up to advance forward in the alphab...

Страница 19: ...aved automatically and the main menu will be brought back unless you are in TS mode in which case you will then be prompted to enter your TS Run Completing is an approximation and it is NOT suggested...

Страница 20: ...redicitions For PLATE MODE the predicted plate will appear in the lower right hand corner of the screen example EZ DL12 or EZ F08 If the prediction is displayed as EZ you do not have enough runs enter...

Страница 21: ...ome parameters may not be enabled depending on the setup of your PerformBJSF and the options your unit has If you want to graph the data base you just downloaded you first need to reselect the data ba...

Страница 22: ...itude Alt Ratio OA Time in seconds ET will change with a 100 change in oxygen altitude Optional TS Ratio DA Time in seconds Throttle Stop will need to change in order to change ET of car 0 01sec in de...

Страница 23: ...not fit is because the run should have been faster then Run 2 since it is 200 DA less in altitude It is now necessary for Run 3 to be removed from the data base To do this you must use the View Delete...

Страница 24: ...Set Stabilizing This allows you to set the degree of stabilizing The lower the number the more amount of stabilizing and the more accurate the air sample A value of 3 or 4 is suggested unless conditio...

Страница 25: ...ly unplug and plug back in charger for another cycle When the battery is charging the following will be displayed when the BATTERY CHECK option is selected Charging POWER XX When POWER reading is at 1...

Страница 26: ...CLIPSE enclosure is opened not including battery door shall not be liable for injury consequential or other types of damages resulting from the use or misuse of the PerformBJSF ECLIPSE TECHNICAL SUPPO...

Страница 27: ...it does not function correctly after reset contact Tech Support ABBREVIATIONS Temp Temperature degrees Fahrenheit Hum Relative Humidity Press Barometric Pressure Inches of Mercury DA Density Altitude...

Страница 28: ...cond change Good Runs 1 Altitude goes up car loses performance altitude goes down car gains performance 2 60 times consistent no tire slip 3 Wind effects minimal 30 mph front or tail winds are not pre...

Страница 29: ...ns F Select Wind Correction 3 RUN ENTRY Enter View Delete runs in database A View Delete B Add Runs a CURRENT b HELD c MANUAL i Altitude ii Temp Pres Hum 4 PREDICT Enter prediction mode A CURRENT B HE...