14
Troubleshooting Guide
GB
Problem
Cause
Remedy
Engine will not start.
Fuel tap not turned on.
Turn fuel on.
No fuel in tank.
Fill fuel tank.
Oil not
¿
lled to correct level.
Fill oil to correct level.
Engine run switch not turned on.
Set engine control correctly.
Choke not set correctly.
Set engine control correctly.
Spark plug fouled.
Replace / clean spark plug.
Air cleaner blocked.
Replace / clean air
¿
lter.
Engine still will not start.
Major Fault
Contact Agent or Altrad Belle.
Engine runs rough.
Air cleaner blocked.
Replace / clean air
¿
lter.
Spark plug fouled.
Replace / clean spark plug.
Choke set incorrectly.
Set engine control correctly.
Dirty / stale fuel.
Drain and replace fuel.
No electrical output.
Voltage selector switch incorrectly
positioned.
Select the correct voltage.
Circuit breaker tripped.
Re-set circuit breaker.
Fault Finding for Alternators
GB
FAULT
OFF Load
No Voltage
Output
Incorrect
Voltage
Voltage
Unstable
Check
Residual Voltage
Check
Speed
Check Engine
Governing
Check all
Stator Resistances
Check
Capacitor
Check Rotor
Resistance
Check Rotating
Diodes
ON Load
Over-
heating
Over Load
Inlet or Outlet
Opening
Obstructed
Hot Engine
or Generator
Air Circulating
Voltage
Unstable
Check
Engine
Governing
Check
Connections
Incorrect
Voltage
Check
Speed
No Output
Voltage
Check Load
for Short
Circuit
Содержание GPX 2700