background image

Appendix A: Warning Statements

 

93

 

 

 

¡Advertencia!

 

Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar 

por completo el suministro de energía, deben desconectarse todas las conexiones.

 

 

Attention

 

Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout 

courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.

 

 

 

םא

 

םייק

 

רתוי

 

קפסמ

 

דחא

 

הרהזא

הדחיל

 

שי

 

רתוי

 

רוביחמ

 

דחא

 

לש

 

קפס

.

 

שי

 

ריסהל

 

תא

 

לכ

 

םירוביחה

 

לע

 

תנמ

 

ןקורל

 

תא

 

הדיחיה

.

 

 

ق

د

 ي

ك

و

ن

 ل

ه

ذ

ا 

ال

ج

ها

ز

 

ع

د

ة

 

تا

ص

ا

لا

ت

 ب

و

ح

د

تا

 

ما

د

دا

 

ال

ط

اق

ة

 .

 

بجي

 

زإ

ال

ة 

اك

ف

ة 

ا

لا

ت

اص

لا

ت

 

لسعل

 ا

ول

ح

د

ة

 

ع

ن

 ا

ل

رهك

با

ء

 

 

 

경고

!

 

 

장치에는

 

 

 

이상의

 

전원

 

공급

 

단자가

 

연결되어

 

있을

 

 

있습니다

 

장치에

 

전원을

 

차단하기

 

위해서는

 

모든

 

연결

 

단자를

 

제거해야만

 

합니다

.

 

 

Waarschuwing

 

Deze eenheid kan meer dan één stroomtoevoeraansluiting bevatten. Alle aansluitingen dienen

 

verwijderd te worden om het apparaat stroomloos te maken.

 

Содержание R360 F5 LFF

Страница 1: ...R360 F5 USER S MANUAL Revision 1 0 ...

Страница 2: ...ltos Computer Inc you may not copy any part of thisdocument Information in this document is subject to change without notice Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders ...

Страница 3: ...se of the server Installation and maintenance should be performed by experienced technicians only Warnings Special attention should be given to the following symbols used in this manual Warning Indicates important information given to prevent equipment property damage or personal injury Warning Indicates high voltage may be encountered when performing a procedure ...

Страница 4: ... 8TB of PMem and 4TB DDR4 Up to 3200MHz size up to 256GB Note PMem 200 Series are supported on 3rd gen Intel Xeon Scalable Platinum Gold and selected Silver processors Drive Support Twelve hot swap 2 5 SATA SAS NVMe hybrid drive bays Two SuperDOM disk on modules Expansion Slots Two PCIe 4 0 x16 FH 10 5 L One PCIe 4 0 x16 LP One PCIe 4 0 x16 LP internal I O Ports LAN ports depend on One VGA port re...

Страница 5: ...28 Mellanox ConnectX 6 PCIe 4 0 x16 Internal four NVMe ports Storage Protocols The storage drive bays can support SATA SAS and NVMe in any combination To enable SAS and NVMe additional hardware is required Once the supporting hardware is installed for a selection of bays drives of any storage protocol type can be inserted SATA The default configuration supports up to twelve SATA drives SAS An add ...

Страница 6: ...nt View R360 F5 SFF Figure 1 1 Front View Logical Storage Drive Numbers Item Description 0 5 2 5 hot swap SATA SAS3 NVMe drive bays NVMe from CPU1 6 11 2 5 hot swap SATA SAS3 NVMe drive bays NVMe from CPU2 SAS3 and NVMe support requires with additional parts R360 F5 LFF USB 3 0 Port Service Asset Tag with BMC Password Control Panel 1 0 3 2 5 4 7 6 9 8 11 10 ...

Страница 7: ...this manual Drive Carrier LED Indicators Color Blinking Pattern Behavior for Device Activity LED Blue Solid On Idle SAS or NVMe drive installed Blue Blinking I O activity Off Idle SATA or no drive Status LED Red Solid On Failure of drive with RSTe support Red Blinking at 1 Hz Rebuild drive with RSTe support Red Blinking at 4 Hz Identify drive with RSTe support Red Blinking with two blinks and one ...

Страница 8: ...Ns when flashing HDD Indicates activity on the storage drives when flashing Power LED Steady on Power on Blinking at 4Hz Checking BIOS BMC integrity Blinking at 4Hz and i LED is blue BIOS firmware updating Two blinks at 4Hz one pause 2hz and i LED blue BMC firmware updating Blinking at 1Hz and i LED red Fault detected Power button The main power switch applies or removes primary power from the pow...

Страница 9: ...as been activated locally to locate the server in a rack environment Blue blinking at 1Hz UID has been activated using the BMC to locate the server in a rack environment Blue blinking at 2Hz BMC is resetting Blue blinking at 4Hz BMC is setting factory defaults Blue blinking at 10Hz with Power LED blinking green BMC BIOS firmware is updating ...

Страница 10: ...nd BMC reset button similar to Control Panel button on previous page COM Serial port VGA Video port Expansion Slots and Riser Cards This system include riser cards that provide PCIe capabilities one Ultra Riser card described in Section 1 1 one right facing WIO riser card and one left facing WIO riser card Riser Card Slot Description all PCIe 4 0 Ultra Riser card 1 x16 Internal LP CPU2 Right facin...

Страница 11: ...e module Power Supply Indicator LED Color and State Power Supply Condition Solid Green Indicates that the power supply is on Blinking Green Indicates that the power supply is plugged in and turned off by the system Blinking Amber Indicates that the power supply has a warning condition and continues to operate Solid Amber Indicates that the power supply is plugged in and is in an abnormal state The...

Страница 12: ... Feature Description Power Supply Dual redundant modules see options on a previous page SATADOM ports Two Disk on Module ports allows for flash cards to be mounted directly on the Motherboard DIMM slots 32 memory slots Processors Dual Intel Xeon Scalable Processors with heatsinks SNK P0077P System fans Eight 4 cm dual counter rotating PWM fans FAN 0201L4 ...

Страница 13: ...ocations of the system electrical components and a block diagram of the overall system Main Components Riser Card Left facing Ultra Riser Card options Motherboard X12DPU 6 Storage Backplane BPN NVMe4 119A S12 manual Figure 1 5 Main Component Locations Riser Card Right facing ...

Страница 14: ... 1 Introduction 14 System Block Diagram The block diagram below shows the connections and relationships between the subsystems and major components of the overall system Figure 1 6 System Block Diagram BMC LAN ...

Страница 15: ... GPU3PW3 GPU3PW4 CPU1 BIOS LICENS E JGPW3 JGPW4 X12DPU 6 REV 1 02 SXB3_3 GPU PWR2 CPU2 GPU PWR1 T SGPIO3 JPW4 JPW3 JPW4 JPW3 JGPW1 P2 DIMMF1 P2 DIMMF2 P2 DIMME1 P2 DIMME2 P2 DIMMB1 P2 DIMMB2 P2 DIMMA1 P2 DIMMA2 P2 DIMMD1 P2 DIMMD2 P2 DIMMC1 P2 DIMMC2 JF1 JF1 JF2 JL1 JL1 P1_NVMe6 P1_NVMe5 JPW2 JPW1 JNVI2C3 JNVI2C3 JF3 JF4 FAN5 JF3 JF4 FAN8 P1 NVMe4 FAN7 FAN6 P1 NVMe6 P2 NVME8 P2 NVME7 FAN3 FAN2FAN1...

Страница 16: ... VPP 2 JGPW1 JGPW2 JGPW3 JGPW4 GPU 8 pin power connectors power connectors for GPU use JPW1 JPW2 JPW3 JPW4 Backplane 8 pin power connectors for backplane devices JUIDB UID LED BMC Reset switch JVGA2 Front accessible VGA connection header optional PSU1 PSU2 Power Supply Unit 1 Power Supply Unit 2 for system use JSD1 JSD2 SATA DOM Disk_On_Module power connectors JTPM1 Trusted Platform Module connect...

Страница 17: ... x8 x8 3bit 5bit 8 15 Port C 0 10 Port C 11 15 10 4G 11 2G T s Polarity Inversion P1F P1E P1H P1G x4 PE2 PE1 PE0 UPI3UPI2 UPI0 10 4G 11 2G T s Polarity Inversion P1C P1D P1A P1B P2F P2E P2H P2G P2C P2D P2A P2B 2 2 3 3 2 2 3 3 DMI CPU 1 Socket ID00 VCCP1 1 1 1 2 2 1 1 1 2 2 2 1 1 2 2 1 1 2 2 x8 NVMe On Board OCuLink OCuLink PE3 VCCP1 12v VR13HC UPI1 NVMe On Board OCuLink OCuLink 10 4G 11 2G T s VCC...

Страница 18: ...Chapter 1 Introduction 18 OCuLink x4 x4 4x4 7 1 PHASE x4 x4 4x4 7 1 PHASE x8 OCuLink OCuLink OCuLink OCuLink x4 x4 x4 x4 Figure 1 8 Motherboard Block Diagram ...

Страница 19: ... be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated It will also require a grounded AC power outlet nearby Be sure to read the precautions and considerations noted in Appendix A 2 3 Preparing for Setup The box in which the system was shipped should include the rackmount hardware needed to install it into th...

Страница 20: ...ty precautions in Appendix A Determine the placement of each component in the rack before you install the rails Install the heaviest server components at the bottom of the rack first and then work your way up Use a regulating uninterruptible power supply UPS to protect the server from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and ...

Страница 21: ... be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelin...

Страница 22: ...e installation instructions that came with the specific rack you are using Identifying the Rails The chassis comes with two sets of rack rails one set for the right side of the chassis and one for the left Each set consists of an inner rail that is pre attached to the chassis an outer rail that attaches to the rack and a middle rail that slides forward in the outer rail Inner rail pre attached to ...

Страница 23: ...securing the rail to the rack Keep the rail horizontal 2 Adjust the rail to reach just past the full depth of your rack 3 Align the square pegs on the rear end of the rail to the holes on the rack D and push the rail into the rack until the quick release bracket snaps into place securing the rail to the rack Bracket with square pegs Figure 2 2 Installing the Outer Rails to the Rack Note The figure...

Страница 24: ...middle rails and then push evenly on both sides of the chassis until it clicks into the fully extended position 3 Depress the locking tabs on both sides of the chassis and push the it fully into the rack The locking tabs should click 4 Thumb screws may be used to secure the front of the chassis to the rack Figure 2 3 Installing the Server into the Rack Notes Keep the ball bearing shuttle locked at...

Страница 25: ...ting the chassis when removing it from the rack Use a lift 1 If necessary loosen the thumb screws on the front of the chassis that hold it in the rack 2 Pull the chassis forward out the front of the rack until it stops 3 Press the release latches on each of the inner rails downward simultaneously and continue to pull the chassis forward and out of the rack Inner rail latch Figure 2 4 Removing the ...

Страница 26: ... Please follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installing non hot swap components or when replacing a non redundant power supply 1 Use the operating system to power down the system 2 After the system has completely shut down disconnect the AC power cord ...

Страница 27: ...se buttons and slide the cover toward the rear 2 Lift the top cover up Check that all ventilation openings on the top cover and the top of the chassis are clear and unobstructed Caution Except for short periods of time do not operate the server without the cover in place The chassis cover must be in place to allow for proper airflow and to prevent overheating Figure 3 1 Removing the Chassis Cover ...

Страница 28: ...d from all power supplies Check that the plastic protective cover is on the CPU socket and that none of the socket pins are bent If they are contact your retailer When handling the processor avoid touching or placing direct pressure on the land grid array gold contacts Improper installation or socket misalignment can cause serious damage to the processor or the socket and may require manufacturer ...

Страница 29: ...g down Locate the gold triangle at the corner of the processor and the corresponding hollowed triangle on the processor carrier as shown below These triangles indicate the location of pin 1 Pin 1 Processor Carrier 2 Turn the processor over with the gold LGA up Locate the CPU keys on the processor and the four latches on the carrier as shown below Processor Reverse Side Up Latch Latch Carrier Top S...

Страница 30: ... those on the carrier a b as shown below 5 Carefully place one end of the processor under latch 1 on the carrier and then press the other end down until it snaps into latch 2 and is properly seated on the carrier Processor Carrier Assembly Top View Processor Carrier Assembly Underside view processor CPU Key on the carrier b Latch CPU Key on the processor Latch CPU Key on the carrier ...

Страница 31: ...e thermal grease facing up Note the two triangle cutouts A B located at the diagonal corners of the heatsink as shown in the drawing below 2 On the processor carrier assembly find pin 1 as noted by the triangles Hold the processor carrier assembly over so that the gold LGA is facing up 3 Align clip a pin 1 on the carrier assembly with the triangular cutout A on the heatsink and b c d on the carrie...

Страница 32: ... Component Installation 32 Installing the PHM into the CPU Socket 1 Remove the plastic protective cover from the CPU socket Gently squeeze the grip tabs then pull the cover off CPU Socket with Plastic Protective Cover Grip Tabs ...

Страница 33: ... Locate four PEEK nuts A B C D and four rotating wires 1 2 3 4 on the heatsink as shown below Rotating WirePeek Nut Rotating Wire 4 Rotating Wire2 B D Heatsink Rotating Wire 3 C Unlatched latched Rotating Wire 1 A Peek Nut CPU Socket 4 Check that the rotating wires 1 2 3 4 are in the unlatched position as shown A B C D Peek Nut 1 2 3 4 Rotating Wire a b c d Threaded Fastener Unlatched State ...

Страница 34: ...6 Gently place the heatsink on the CPU socket making sure that each nut is properly aligned with its corresponding threaded fastener A B C D Peek Nut on the Heatsink B Threaded Fastener on the CPU socket 7 Press all four rotating wires outward to latch the PHM onto the CPU socket Rotating Wire 8 With a t30 bit screwdriver tighten all PEEK nuts in the sequence of A B C and D with even pressure not ...

Страница 35: ...nd all AC power cords are unplugged 1 Use a t30 bit screwdriver to loosen the four PEEK nuts on the heatsink in the sequence of A B C and D 2 Press the four rotating wires inward to unlatch the PHM as shown below 3 Gently lift the PHM upward to remove it from the CPU socket Unlatched State Rotating Wire Side View Peek Nut ...

Страница 36: ...or Carrier Assembly from the PHM Detach the four plastic clips a b c d on the processor carrier assembly from the four corners of the heatsink A B C D as shown below and lift off the processor carrier assembly d Processor Carrier Assembly b Pin 1 Pin 1 a D c B Heatsink A C ...

Страница 37: ... the Carrier Assembly Unlock the lever from its locked position and push it upwards to disengage the processor from the carrier as shown below right Carefully remove the processor from the carrier Processor Carrier Assembly Note Handle the processor with care to avoid damage Lever ...

Страница 38: ...Type Ranks Per DIMM and Data Width DIMM Capacity GB Speed MT s and Voltage DRAM Density One DIMM per Channel Two DIMMs per Channel 8Gb 16Gb 1 2V 1 2V RDIMM SRx8 8GB 16GB 3200 3200 SRx4 16GB 32GB DRx8 16GB 32GB DRx4 32GB 64GB RDIMM 3Ds 4R 8R x4 2H 64GB 4H 128GB 2H 128GB 4H 256GB LRDIMM QRx4 64GB 128GB LRDIMM 3Ds 4R 8R x4 4H 128GB 2H 128GB 4H 256GB Only the 83xx and 63xx series support 3200MT s for ...

Страница 39: ...ts Mixing of non 3DS and 3DS LRDIMM is not allowed in the same channel across different channels and across different sockets Mixing of PMem modules and RDIMMs is supported Mixing DDR4 and PMem memory operating frequencies is not validated within a socket or across sockets If DIMMs of different frequencies are mixed in the same channel all DIMs will run at the highest common frequency Always popul...

Страница 40: ... C1 D1 E1 F1 G1 H1 CPU2 A1 B1 C1 D1 E1 F1 G1 H1 2 CPUs 18 DIMMs CPU1 A1 A2 B1 C1 C2 D1 E1 E2 F1 G1 G2 H1 CPU2 A1 B1 C1 E1 F1 G1 2 CPUs 20 DIMMs CPU1 A1 A2 B1 C1 C2 D1 E1 E2 F1 G1 G2 H1 CPU2 A1 B1 C1 D1 E1 F1 G1 H1 2 CPUs 22 DIMMs CPU1 A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 CPU2 A1 B1 C1 E1 F1 G1 2 CPUs 24 DIMMs CPU1 A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 CPU2 A1 B1 C1 D1 E1 F1 G1...

Страница 41: ...4 DDR4 DDR4 DDR4 DDR4 DDR4 PM DDR4 DDR4 PM DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 PM DDR4 DDR4 DDR4 DDR4 DDR4 1 x4 DDR4 DDR4 PM DDR4 DDR4 PM PM DDR4 DDR4 PM DDR4 DDR4 8 DDR4 4 PMem AD MM 2 x2 DDR4 DDR4 PM DDR4 PM DDR4 DDR4 PM DDR4 PM DDR4 DDR4 1 x4 DDR4 PM DDR4 DDR4 DDR4 PM PM DDR4 DDR4 DDR4 PM DDR4 2 x2 DDR4 PM DDR4 DDR4 PM DDR4 DDR4 PM DDR4 DDR4 PM DDR4 8 DDR4 8 PMem AD MM One x8 DDR4...

Страница 42: ...ptimized PMem to DRAM cache ratio in MM and MM AD modes For each individual population different PMem rearrangements among channels are permitted so long as the configuration does not break X12 DP Memory population rules Ensure the same DDR4 DIMM type and capacity are used for each DDR4 PMem popu lation If the system detects an unvalidated config then the system issues a BIOS warning The CLI funct...

Страница 43: ... power from the system as described in Section 3 1 Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release Tabs 2 Align the key of the DIMM with the receptive point on the memory slot and with your thumbs on both ends of the module press it straight down into the slot until the module snaps into place Key ...

Страница 44: ...th the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous waste management agency to dispo...

Страница 45: ...es are mounted in tool less drive carriers that simplify their removal from the chassis These carriers also help promote proper airflow Note Enterprise level hard disk drives are recommended For information on recommended drives Installing Drives Figure 3 4 Logical Drive Numbers Removing a Hot Swap Drive Carrier from the Chassis 1 Press the release button on the drive carrier which will extend the...

Страница 46: ... BMC Dashboard Server Health NVMe SSD 2 Select Device Group and Slot and click Eject After ejecting the drive Status LED indicator turns green 3 Remove the drive Note that Device and Group are categorized by the CPLD design architecture Slot is the slot number on which the NVMe drives are mounted Figure 3 8 BMC Dashboard Screenshot Replacing the Drive 1 Insert the replacement drive 2 BMC Dashboard...

Страница 47: ...ws the single highest temperature among all the NVMe drives 3 7 System Cooling Fans Eight 4 cm counter rotating fans provide the cooling for the system Each fan unit is actually made up of two fans joined back to back which rotate in opposite directions This counter rotating action generates exceptional airflow and works to dampen vibration levels Make sure the chassis top cover makes a good seal ...

Страница 48: ...elow 2 Align the notch on the air shroud with the pin on the expansion card bracket 3 Slide the pin into the back of the notch 4 Lower the front of the air shroud over the fan tray sliding the front notches over the pins on the fan tray Note Take care that the shroud does not interfere with other components such as a DIMM latch before re installing the chassis cover Air Shrouds Waiting to add Smar...

Страница 49: ...When illuminated indicates that the power supply is on Blinking Green When blinking indicates that the power supply is plugged in and turned off by the system Blinking Amber When blinking indicates that the power supply has a warning condition and continues to operate Solid Amber When illuminated indicates that the power supply is plugged in and is in an abnormal state The system might need servic...

Страница 50: ...one right facing WIO riser card and one left facing WIO card PCIe Slots per Riser Card Riser Card Part Number Slot Description all PCIe 4 0 Ultra Riser card AOC URG4N4 AOC URG4N4 i2XT AOC URG4N4 i4XTS AOC URG4N4 m2TS 1 x16 Internal LP CPU2 Right facing RSC WR 6 2 x16 low profile CPU1 Left facing RSC W 66G4 3 4 x16 FH 10 5 L CPU2 x16 FH 10 5 L CPU1 Full height 4 2 Low profile 2 5 Full length 10 5 H...

Страница 51: ...essary attach the riser card to the riser card bracket using screws 4 Insert the expansion card into a slot on the riser card while aligning the expansion card backplate with the open slot in the rear of the chassis 5 Re install the riser card bracket inserting the riser card into the motherboard expansion slot while aligning the riser card bracket with the rear of the chassis 6 For GPUs if necess...

Страница 52: ...Chapter 3 Maintenance and Component Installation 52 Expansion Cards new bracket coming soon Internal Expansion Card Figure 3 11 Expansion cards Installed ...

Страница 53: ...emove the cover 2 Locate the mounting brackets and standoff in the accessories box Mount the brackets to hold the expansion card onto the Ultra riser card Figure 3 12 Bracket for Mounting an Internal Expansion Card on the Ultra Riser Card four port Ultra card shown in this example 3 Insert the card into the expansion slot on the Ultra riser card and secure it to the brackets Removing the Ultra Ris...

Страница 54: ...system SAS cable routing depends on the model and position of the SAS controller card so routing is not shown here Online Cable Matrix Figure 3 14 Cable Routing Diagram Figure 3 15 Storage Backplane BPN NVMe4 119A S12 manual SATA Cable Backplane Power Cable Front Panel USB Cable Front Panel Control Cable Optional NVMe Cables CBL KIT 120U TNR 12 Optional SAS Cables not shown ...

Страница 55: ...nector Two proprietary main power headers are located at PSU1 and PSU2 Connect appropriate power supply units to these two headers to provide adequate power to your system Important To provide adequate power to the motherboard connect the both main power connectors and 8 pin power connectors to the power supply Failure to do so may void the manufacturer s warranty on your power supply and motherbo...

Страница 56: ... Pin Definition 1 Ground Black 2 12V Red 3 Tachometer 4 PWM Control SGPIO Header A Serial General Purpose Input Output header T SGPIO3 is used to communicate with the enclosure management chip on the backplane SGPIO Header Pin Definitions Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 DATA Out 5 Load 6 Ground 7 Clock 8 NC NC No Connection Disk On Module Power Connector Two power connectors for...

Страница 57: ... 1 P3V3 2 SPI_TPM_CS_N 3 PCIe_RESET_N 4 SPI_PCH_MISO 5 SPI_PCH_CLK 6 Ground 7 SPI_PCH_MOSI 8 N A 9 JTPM1_P3V3A 10 IRQ_TPM_SPIN_N NVMe SMBus Headers NVMe SMBus I2 C headers JNVI2 C3 4 used for PCIe SMBus clock and data connections provide hot plug support through a dedicated SMBus interface This feature is only available for a Altos complete system with a proprietary NVMe add on card and cable inst...

Страница 58: ...ok different Header JRK1 Chassis Intrusion A Chassis Intrusion header is located at JL1 on the motherboard Attach the appropriate cable from the chassis to the header to inform you when the chassis is opened Chassis Intrusion Pin Definitions Pins Definition 1 Intrusion Input 2 Ground 4 pin BMC External I2 C Header A System Management Bus header for the BMC is located at JIPMB1 Connect a cable to t...

Страница 59: ... LED NIC2 Activity LED NIC2 Link LED NIC1 Activity LED NIC1 Link LED ID_UID 3 3V Stby HDD LED 3 3V FP PWR LED Key Key NMI Ground 19 20 Figure 4 1 JF1 Control Panel Pins Power Button The Power Button connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be configured to function as a suspend button with a setting in the UEFI ...

Страница 60: ...n for LAN port 2 is on pins 9 and 10 Attach the NIC LED cables here to display network activity LAN1 LAN2 LED Pin Definitions JF1 Pin Definition 9 NIC2 Activity LED 10 NIC2 Link LED 11 NIC1 Activity LED 12 NIC1 Link LED HDD LED UID Switch The HDD LED UID Switch connection is located on pins 13 and 14 of JF1 Attach a cable to Pin 14 to show hard drive activity status Attach a cable to pin 13 to use...

Страница 61: ...nnection is located on pins 15 and 16 of JF1 Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Power LED NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 NMI Button Pin Definitions JF1 Pin Definition 19 Control 20 Ground ...

Страница 62: ...icate LAN port for the BMC There can also be two four or zero network LAN ports on the chassis rear provided by the Ultra riser card depending on the option you purchased Unit Identifier Switch UID LED Indicator A Unit Identifier UID switch and a UID LED indicator are located on the rear of the system When you press the UID switch both front and rear UID LED indicators are toggled on or off The UI...

Страница 63: ...og function Watchdog is a monitor that can reboot the system when a software application hangs Jumping pins 1 2 will cause Watch Dog to reset the system if an application hangs Jumping pins 2 3 will generate a non maskable interrupt signal for the application that hangs Watchdog must also be enabled in BIOS The default setting is Reset Note When Watchdog is enabled the user must write their own ap...

Страница 64: ...he BMC LAN port indicates activity while the LED color on the left indicates the speed of the connection Unit ID LED Link LED speed Activity LED A rear unit identifier UID indicator at LED1 is located near the UID switch on the I O back panel It provides easy identification of a unit that may need service Onboard Power LED The Onboard Power LED is LE2 When this LED is on the system power is on BMC...

Страница 65: ...not require externalpower cables Altos SuperDOMs are compatible with regular SATA HDDs or SATA DOMs that need external power cables NVMe Connectors The motherboard offers the following NVMe headers P1 NVMe0 1 one Supports two NVMe backplane ports P1 NVMe3 4 5 6 four Each supports one NVMe backplane port P2 NVMe7 8 9 10 four Each supports one NVMe backplane port The P1 headers are supported by CPU1...

Страница 66: ... 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive or the BMC KVM console 2 Retrieve the proper RST RSTe driver Go to the Altos web page for your motherboard and click on Download the Latest Drivers and Utilities select the properdriver and copy it to a USB flash drive 3 Boot from a bootable device...

Страница 67: ...river browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the SATA sSATA AHCI driver indicated then choose the storage drive on which you want to install it 5 Once all devices are specified continue with the installation 6 After the Windows OS installation has c...

Страница 68: ...lity to extract the ISO file if preferred Figure 5 3 Driver Tool Installation Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of these items to install each item from top to the bottom one at a time After installing each item you must re boot the system before moving on to the next item on the list The bottom ...

Страница 69: ...cols Supported The storage drive bays can support SATA SAS and NVMe in any combination To enable SAS and NVMe additional hardware is required Once the supporting hardware is installed for a selection of bays drives of any storage protocol type can be inserted SATA The default configuration supports up to twelve SATA drives SAS An add on controller card and cables can support up to twelve SAS drive...

Страница 70: ...Chapter 6 Optional Components 70 2000 PWS 2K08A 1R Titanium 1300 DC PWS 1K30D 1R Not applicable ...

Страница 71: ...nce The CMA attaches to the rack mounting rails by means of four connectors They are labeled on the connectors 1 2 3 and 4 Figure 6 1 Cable Management Arm Installing the Cable Management Arm 1 Slide CMA connector 1 forward onto the two posts on the rear of the right inner rail right side when viewed from the front It snaps into place 2 Slide CMA connector 2 forward onto the two posts on the rear o...

Страница 72: ...er rail and push it forward It snaps into place 5 Route the cables through the holding brackets leaving enough slack Removing the Cable Management Arm 1 Remove cables from the CMA 2 For CMA connector 4 pull the metal release tab toward the center of the rack and slide the connector toward the rear to release it 3 For CMA connectors 3 2 and 1 depress the front edge of the yellow plastic rocker lock...

Страница 73: ...70 controller vertical form factor The JTPM1 header is used to connect a Trusted Platform Module TPM A TPM is a security device that supports encryption and authentication in hard drives It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system ...

Страница 74: ...Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise Intel RSTe Driver for Windows To enable Intel VROC a hardware key must be inserted on the motherboard and the ap propriate processor s Virtual Management Devices must be enabled in the BIOS setup It is pos...

Страница 75: ...y must be plugged into the Altos motherboard connector JRK1 The key options are VROC Package Description Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs 951605 Premium RAID 0 1 5 10 Supports 3rd party SSDs 951606 Intel SSD only RAID 0 1 5 10 Supports Intel SSDs only 956822 VROC Key Header JRK1 Figure 6 6 Intel VROC RAID Key and Motherboard Connector JRK1 ...

Страница 76: ...ns 2 Switch to Advanced Chipset Configuration North Bridge IIO Configuration Intel VMD Technology Figure 6 7 BIOS Selecting VMD Mode You can select a mode The default is Auto The VMD switch enables VMD mode for all NVMe ports despite the presence of the VROC key The Manual switch allows the user to choose devices on which to enable VMD The onboard M 2 NVMe from PCH is located in the CPU1 section T...

Страница 77: ...ional Components 77 Figure 6 8 BIOS Manual Mode Example your server may look different 3 Select the desired PStack to Enable or Disable the corresponding Intel VMD controller Figure 6 9 BIOS Enabling VMD for Pstack0 ...

Страница 78: ...Capability can also be Enabled or Disabled Figure 6 10 BIOS Enabling VMD Functionality per Slot 5 Repeat steps 3 and 4 for each PStack on each CPU to be enabled or disabled In this example we enabled CPU1 Slot1 Figure 6 11 and CPU2 Slot5 Figure 6 12 four U 2 form factor SSDs as well as CPU1 M 2 C 1 and CPU1 M2 C 2 two M 2 form factor SSDs Figure 6 11 BIOS Enabling CPU1 Example ...

Страница 79: ... without first deleting the associated existing RAID volume can lead to unexpected behavior This action is strongly not recommended Note The effects of physically changing or swapping a CPU on the VMD controller enablement has not yet been thoroughly tested or documented 7 Switch to Advanced Intel R Virtual RAID on CPU All Intel VMD Controllers Create RAID Volume 8 Set Name 9 Set RAID Level ...

Страница 80: ...ler Figure 6 14 Created Volume with enabling RAID spanned over VMD controller 11 Select specific disks for RAID with an X RAID0 Select at least two 2 24 disks RAID1 Select only two disks RAID5 Select at least three 3 24 disks RAID10 Select only four disks 12 Select Strip Size Default 64KB 13 Select Create Volume 14 If another RAID is needed start again at step 9 15 Press F4 to save and reboot ...

Страница 81: ... at link 1 below Hot unplug 1 Prevent devices from being re detected during rescan esxcli storage core claiming autoclaim enabled false 2 Unmount the VMFS volumes on the device Check 2 for details 3 Detach the device Check 3 for details 4 Physically remove the device Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Re...

Страница 82: ...g This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents 警告の定義 この警告サインは危険を意味します 人身事故につながる可能性がありますので いずれの機器でも動作させる前に 電 気回路に含まれる危険性に注意して 標準的な事故防止策に精通して下さい 此警告符号代表危险 您正处于可能受到严重伤害的工作环境中 在您使用设备开始工作之前 必须充分意识到触电 的危险 并熟...

Страница 83: ...el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉ CURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraî ner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés aux ...

Страница 84: ...니다 해당 번역문을 찾기 위해 각 경고의 마지막 부분에 제공된 경고문 번호를 참조하십시오 BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwings symbool betekent gevaar U verkeert in een situatie die lichamelijk letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te v...

Страница 85: ...קור מתח ا ق ر إر ش ا دات ا ل رت ك يب قبل تو ص يل ا لنظا م إ ىل مصد ر للطا ق ة 시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오 Waarschuwing Raadpleeg de installatie instructies voordat u het systeem op de voedingsbron aansluit Circuit Breaker Warning This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective device is rated not greater than 250 V 20 A サーキッ...

Страница 86: ... ce produit dépend de l installation électrique du local Vérifiez que le courant nominal du dispositif de protection n est pas supérieur à 250 V 20 A מוצר זה מסתמך על הגנה המותקנת במבנים למניעת קצר חשמלי יש לוודא כי המכשיר המגן מפני הקצר החשמלי הוא לא יותר מ 20A 250VDC هذا املنتج يعتمد عىل معداث الحاميت مه الدوائرالقصرية التي تم تثبيتها يف املبنى تأ كد م ن أ ن تقييم ا لجها ز ا لو ق ا ي ئ ل يس أ ك ...

Страница 87: ... Quellen der Energie und vom Netzanschlusskabel getrennt sein das von den Spg Versorgungsteilmodulen entfernt wird bevor es auf den Chassisinnenraum zurückgreift um Systemsbestandteile anzubringen oder zu entfernen Advertencia El sistema debe ser disconnected de todas las fuentes de energí a y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior de...

Страница 88: ...코드를 분리해주어야 합니다 Waarschuwing Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren of verwijderen van systeem onderdelen dient u alle spanningsbronnen en alle stroomkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment 機器の設置 トレーニ...

Страница 89: ...يه 경고 훈련을 받고 공인된 기술자만이 이 장비의 설치 교체 또는 서비스를 수행할 수 있습니다 Waarschuwing Deze apparatuur mag alleen worden geï nstalleerd vervangen of hersteld door geschoold en gekwalificeerd personeel Restricted Area Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security This warn...

Страница 90: ...une zone d accès réservé n est possible qu en utilisant un outil spécial un mécanisme de verrouillage et une clé ou tout autre moyen de sécurité אזור עם גישה מוגבלת אזהרה יש להתקין את היחידה באזורים שיש בהם הגבלת גישה הגישה ניתנת בעזרת כלי אבטחה בלבד מפתח מנעול וכד تخصيص ه ذ ه ا ن ىحذ ة نتر ك ب ُ ه ا ف م نا طق م حظو رة تم ُ م ك ن ان ى ص ى ل إن م ن ط ق ت م ح ظو رة ف ق ط م ن خ ا لل اس ت خ ذاو أداة خ...

Страница 91: ...tterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers Attention Danger d explosion si la pile n est pas remplacée correctement Ne la remplacer que par une pile de type semblable ou équivalent recommandée par le fabricant Jeter les piles usagées conformément aux instructions du fabricant Advertencia Exist...

Страница 92: ...de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All connec tions must be removed to de energize the unit 冗長電源装置 このユニットは複数の電源装置が接続されている場合があります ユニットの電源を切るためには すべての接続を取り外さなければなりま...

Страница 93: ...s les connexions d alimentation doivent être débranchées אם קיים יותר מספק אחד אזהרה ליחדה יש יותר מחיבור אחד של ספק יש להסיר את כל החיבורים על מנת לרוקן את היחידה ق د ي ك و ن ل ه ذ ا ا ل ج ه ا ز ع د ة ات ص ا ال ت ب و ح د ات ام د اد ا ل ط ا ق ة يجب إز ا ل ة كا ف ة ا ال ت صا ال ت لعسل ا لو ح د ة ع ن ا ل كهر ب ا ء 경고 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다 이 장치에 전원을 차단하기 위해서는 모든 연결 단자를 제거해야만 합니다 Waa...

Страница 94: ... Warnung Wenn das System in Betrieb ist treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors ...

Страница 95: ...htigheid is geboden tijdens het onderhoud Comply with Local and National Electrical Codes Warning Installation of the equipment must comply with local and national electrical codes 地方および国の電気規格に準拠 機器の取り付けはその地方および国の電気規格に準拠する必要があります 警告 设备安装必须符合本地与本国电气法规 警告 設備安裝必須符合本地與本國電氣法規 Warnung Die Installation der Geräte muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir...

Страница 96: ... moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften Product Disposal Warning Ultimate disposal of this product should be handled according to all national laws and regulations 製品の廃棄 この製品を廃棄処分する場合 国の関係する全ての法律 条例に従い処理する必要があります 警告 本产品的废弃处理应根据所有国家的法律和规章进行 警告 本產品的廢棄處理應根據所有國家的法律和規章進行 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes er...

Страница 97: ...e uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen Hot Swap Fan Warning Warning Hazardous moving parts Keep away from moving fan blades The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing ファン ホットスワップ...

Страница 98: ...eur du châssis Prenez garde à ce que doigts tournevis et autres objets soient éloignés du logement du bloc ventilateur אזהרה חלקים נעים מסוכנים התרחק מלהבי המאוורר בפעולהכאשר מסירים את חלקי המאוורר מהמארז יתכן והמאווררים עדיין עובדים יש להרחיק למרחק בטוח את האצבעות וכלי עבודה שונים מהפתחים בתוך המאוורר تحذير خطرة متحركة أجزاء املتحركة املروحة شفرات عن ابتعد أن املمكن من إبقاء يجب الهيكل من املروحة...

Страница 99: ...Appendix A Warning Statements 99 buurt van de openingen in de ventilatorbehuizing ...

Страница 100: ...ブル UL CSAマークがコードに表記 を Altos が指定 する製品以外に使用することを禁止しています 警告 安装此产品时 请使用本身提供的或指定的或采购的连接线 电源线和电源适配器 包含遵照当 地法规和安全要求的合规的电源线尺寸和插头 使用其它线材或适配器可能会引起故障或火灾 除了Altos所指定的产品 电气用品和材料安全法律规定禁止 使用未经UL或CSA认证的线材 线材上会显示UL CSA符号 警告 安裝此產品時 請使用本身提供的或指定的或採購的連接線 電源線和電源適配器 包含遵照當 地法規和安全要求的合規的電源線尺寸和插頭 使用其它線材或適配器可能會引起故障或火災 除了Altos所指定的產品 電氣用品和材料安全法律規定禁止 使用未經UL或CSA認證的線材 線材上會顯示UL CSA符號 Warnung Nutzen Sie beim Installieren des Produkt...

Страница 101: ...eurs peut provoquer un dysfonctionnement ou un incendie Appareils électroménagers et la Loi sur la Sécurité Matériel interdit l utilisation de câbles certifies UL ou CSA qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques sauf les produits désignés par Altos seulement AC ימאתמו םיילמשח םילבכ הרהזא ךרוצל ומאתוה וא ושכרנ רשא AC םימאתמו םיקפס םילבכב שמתשהל שי רצומה תא םינ...

Страница 102: ...n van het Product uitsluitend gebruik maken van de geleverde Kabels of een andere geschikte aan te schaffen Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing of brand veroorzaken Wetgeving voor Elektrische apparatuur en Materiaalveiligheid verbied h...

Страница 103: ... SATA SAS or NVMe can be supported with additional equipment Two SuperDOM Disk on Module headers PCI Expansion Slots Two PCIe x16 full height 10 5 length One PCIe x16 low profile One internal PCIe x16 low profile Ultra riser Input Output Network Zero two or four LAN ports varies by model BMC Dedicated LAN port USB Three USB 3 0 ports 2 rear 1 front Video One VGA port COM port One serial header Mot...

Страница 104: ...CISPR 32 AS NZS CISPR 32 BS EN55032 BS EN55035 CISPR 32 CISPR 24 CISPR 35 BS EN 61000 3 2 BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 8 BS EN 61000 4 11 Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive California Proposition 65 Product Safety 2014 35 EU LVD Directive UL CSA 62368 1 USA and Canada El...

Отзывы: