background image

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

IMPORTANT SAFETY INSTRUCTION

TO REDUCE THE RISK OF ELECTRIC SHOCK
PLEASE DO NOT REMOVE THE COVER OR
THE BACK PANEL OF THIS EQUIPMENT.
THERE ARE NO PARTS NEEDED BY USER
INSIDE THE EQUIPMENT. FOR SERVICE,
PLEASE CONTACT QUALIFIED SERVICE
CENTERS.

WARNING

To reduce the risk of electric shock
and fire, do not expose this equipment
to moisture or rain.

1.
2.
3.

4.

5.

6.

7.

8.

9.

10.

Dispose of this product should
not be placed in municipal waste
and should be separate collection.

11.

12.

Move this Equipment only with a cart,
stand, tripod, or bracket,
specified by the
manufacturer, or
sold with the
Equipment. When
a cart is used, use
caution when
moving the cart /
equipment
combination to
avoid possible
injury from tip-over.
Permanent hearing loss may be caused by
exposure to \ extremely high noise levels.
The US. Government's Occupational Safety
and Health Administration (OSHA) has
specified the permissible exposure to noise
level.
These are shown in the following chart:

HOURS X DAY

EXAMPLE

According to OSHA, an exposure to high SPL in
excess of these limits may result in the loss of
heat. To avoid the potential damage of heat, it is
recommended that Personnel exposed to
equipment capable of generating high SPL use
hearing protection while such equipment is
under operation.

8
6
4
3
2
1,5
1
0,5
0,25 or less

SPL

90
92
95
97

100
102
105
110
115

Small gig
train
Subway train
High level desktop monitors
Classic music concert

Rock concert

This symbol, wherever used, alerts you to the
presence of un-insulated and dangerous voltages

within the product enclosure. These are voltages that
may be sufficient to constitute the risk of electric
shock or death.

This symbol, wherever used, alerts you to

important operating and maintenance instructions.

Please read.

Protective Ground Terminal
AC mains (Alternating Current)
Hazardous Live Terminal

ON:

Denotes the product is turned on.

OFF: Denotes the product is turned off.

The apparatus shall be connected to a mains
socket outlet with a protective earthing
connection.

The mains plug or an appliance coupler is used
as the disconnect device, the disconnect device
shall remain readily operable.

CAUTION

Describes precautions that should be observed to
prevent damage to the product.

Read this Manual carefully before operation.
Keep this Manual in a safe place.
Be aware of all warnings reported
with this symbol.
Keep this Equipment away from water and
moisture.
Clean it only with dry cloth. Do not use
solvent or other chemicals.
Do not damp or cover any cooling opening.
Install the equipment only in accordance with
the Manufacturer's instructions.

Power Cords are designed for your safety. Do
not remove Ground connections! If the plug
does not fit your AC outlet, seek advice from
a qualified electrician. Protect the power
cord and plug from any physical stress to
avoid risk of electric shock. Do not place
heavy objects on the power cord. This could
cause electric shock or fire.

Unplug this equipment when unused for long
periods of time or during a storm.

Refer all service to qualified service personnel
only. Do not perform any servicing other than
those instructions contained within the
User's Manual.

To prevent fire and damage to the product,
use only the recommended fuse type as
indicated in this manual. Do not short-circuit
the fuse holder. Before replacing the fuse,
make sure that the product is OFF and
disconnected from the AC outlet.

Содержание MS1

Страница 1: ...PASSIVE MODELS MS SPEAKER ENCLOSURES OWNER S MANUAL www altoproaudio com Version 1 3 SEPTEMBER 2007 LTO R English ...

Страница 2: ...es that may be sufficient to constitute the risk of electric shock or death This symbol wherever used alerts you to important operating and maintenance instructions Please read Protective Ground Terminal AC mains Alternating Current Hazardous Live Terminal ON Denotes the product is turned on OFF Denotes the product is turned off The apparatus shall be connected to a mains socket outlet with a prot...

Страница 3: ... MS154 and two subwoofers MS15S MS18S This series uses trapezium configuration which greatly decreases the resonance of the standing wave in the cabinet The cabinets use hi density matrix spray paint technics and the bottom bracket design which makes mounting quickly and flexibly HF compression driver and vented LF for fully professional performance The LTO MS1 speaker modeller is designed for usi...

Страница 4: ...ts output terminals with the inputs of a power amplifier Then select the preset as need 3 Complete other connections as illustrated 4 Turn on your mixer and MS1 first then the stereo power amplifier 5 Turn up the volume controls of your amplifier to about 70 6 Use PFL function to get the proper input level for the mixer and adjust the Main Mix Level control to manipulate the output level 7 After u...

Страница 5: ...ad half of the impedance of one speaker INPUT THROUGH INPUT THROUGH 2 Connect the THROUGH socket of the first MS cabinet to the INPUT socket of the second MS cabinet MIXER MS1 INPUT OUTPUT D1 500W 2 dB 12 16 18 20 22 24 26 28 30 6 CH1 dB 12 16 18 20 22 24 26 28 30 6 CH2 SIG CLIP PROT SIG CLIP PROT VIRTUAL SUB STAGE MONITOR JAZZ CLUB CONCERT HALL SUB DISCO VOCAL ROCK ROLL JAZZ CLUB SUB DRUM KICK AR...

Страница 6: ... side to the Input socket of your subwoofer with the second speaker cable connect the Output of the subwoofer to the Input of satellite 3 Complete other connections as illustrated 4 Turn on your mixer and MS1 first then the stereo power amplifier 5 Turn up the volume controls of your amplifier to about 70 6 Use PFL function to get the proper input level for the mixer and adjust the Main Mix Level ...

Страница 7: ...wer LED This LED lights up when the unit is powered on 5 6 7 15VAC POWER LEFT LEFT MONO RIGHT RIGHT TIP PIN 2 RING PIN 3 SLEEVE PIN 1 INPUT OUTPUT TIP PIN 2 RING PIN 3 SLEEVE PIN 1 1 2 3 4 5 AC Inlet This jack is used to connect the AC power supply with the supplied 15V AC adapter 6 Output Connector This is a balanced 1 4 TRS jack which is used to connect devices such as the effects returns on a m...

Страница 8: ...filtered at 125 Hz SPK 1 1 connected 2 2 not connected THRU LINK INPUT SOUND REINFORCEMENT SPEAKER SYSTEM DESIGNED AND DEVELOPMENT IN ITALY POWER HANDLING PEAK 800 Watts IMPEDANCE 8 ohms nominal SERIAL MODEL MS15S LTO R CONTINUOUS 400 Watts 1 2 PASSIVE SUBWOOFER MS15S MS18S 1 INPUT Receive the power coming from an external power amplifier SPK 1 1 connected 2 2 not connected 1 2 THRU LINK INPUT SOU...

Страница 9: ...ive speaker cabinets The power connector has four terminals 1 1 2 2 only In our cabinets only 1 1 are used to connect the Speaker Speaker and 2 2 are not used For Passive Speaker Cabinets For LTO MS1 SPEAKER MODELLER Please use shielded twisting pair which can reduce noise and signal loss The of the connector is as follow wiring Sleeve Tip Ring TRS Type balanced ...

Страница 10: ... Voice Coil 90 H x 60 V Elliptical Wave Guide 2 x SPK4 Power Input Link Trapezoidal Shape Composite Wood Metal Handle Black Paint finishing 750 x 450 x 420 mm 55 07 lbs 24 98 kg MS152 2 Way Vented Box 500 Watt AES Standard 1000 Watt Peak 127 dB Nominal 130 dB Peak 55 Hz 20 kHz at 10 dB 4 Ohms 250 Hz 2 kHz 12 dB Oct Electronic Dynamic Protection 2 x 15 Woofer 2 5 Voice coil 1 Driver 1 35 Voice coil...

Страница 11: ...ut Link Trapezoidal Shape Multi layer Plywood Metal Handle Black Paint finishing 900 x 450 x 415 mm 67 59 lbs 30 66 kg Model Item Passive System Type Continuous Power Peak Power Max SPL at 1m Frequency Response Impedance Crossover Frequency Protection Low Frequency Device Mid Frequency Device High Frequency Device Coverage H x V Connectors Cabinet Dimensions H x W x D Net Weight lbs kg 3 Way Vente...

Страница 12: ...AL 10 Model Item Passive System Type Continuous Power Peak Power Max SPL at 1m Frequency Response Impedance Low High Crossover Frequency Low Frequency Device Connectors Cabinet Dimensions H x W x D MS15S Band Pass 400 Watt AES Standard 800 Watt Peak 123 dB SPL calculated 45 Hz 200 Hz at 10dB 4 Ohm 160 Hz 6dB oct 15 Woofer 3 Voice Coil 2 x SPK4 Power Input Output Multi layer Plywood Black painted M...

Страница 13: ...ou have completed the Warranty Registration Card in time 3 2 The warranty service is only available to the original consumer who purchased this product directly from the retail dealer and it can not be transferred 3 3 During the warranty service may repair or replace this product at its own option at no charge to you for parts or for labor in accordance with the right side of this limited warranty...

Страница 14: ...hotocopy translation or reproduction of part of this manual without written permission is forbidden Copyright 2007 Seikaku Group SEIKAKU TECHNICAL GROUP LIMITED NO 1 Lane 17 Sec 2 Han Shi West Road Taichung 40151 Taiwan http www altoproaudio com Tel 886 4 22313737 email alto altoproaudio com Fax 886 4 22346757 ...

Отзывы: