SAFETY RELATED SYMBOLS

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

This symbol, wherever used, alerts you to the pre-
sence of un-insulated and dangerous voltages with-
in the product enclosure. These are voltages that 
may be sufficient to constitute the risk of electric 
shock or death.

Protective Ground Terminal

AC mains (Alternating Current)

Hazardous Live Terminal

ON:

    Denotes the product is turned on.

This symbol, wherever used, alerts you to impo-
rtant operating and maintenance instructions. 
Please read.

OFF:  

Denotes the product is turned off. 

WARNING

Describes precautions that should be observed to 
prevent the possibility of death or injury to the user.

CAUTION

Describes precautions that should be observed to 
prevent damage to the product.

Protective Ground

Operating Conditions

IMPORTANT SAFETY INSTRUCTIONS

Cleaning

Servicing

Power Cord and Plug

the recommended fuse type as indicated in this 
manual. Do not short-circuit the fuse holder. Before 
replacing the fuse, make sure that the product is 
OFF and disconnected from the AC outlet.

Before turning the product ON, make sure that it is 
connected to Ground. This is to prevent the risk of 
electric shock.

Never cut internal or external Ground wires. Likewise, 
never remove Ground wiring from the Protective 
Ground Terminal.

Always install in accordance with the manufacturer's 
instructions.

To avoid the risk of electric shock and damage, do 
not subject this product to any liquid/rain or moisture. 
Do not use this product when in close proximity to 
water.

Do not install this product near any direct heat source.

Do not block areas of ventilation. Failure to do so 
could result in fire.

Keep product away from naked flames.

Read these instructions

Follow all instructions

Keep these instructions. Do not discard.

Heed all warnings.

Only use attachments/accessories specified by the 
manufacturer.

Do not tamper with the power cord or plug. These are 
designed for your safety.

Do not remove Ground connections!

If the plug does not fit your AC outlet seek advice from 
a qualified electrician.

Protect the power cord and plug from any physical 
stress to avoid risk of electric shock.

Do not place heavy objects on the power cord. This 
could cause electric shock or fire.

When required, either blow off dust from the product 
or use a dry cloth.

Do not use any solvents such as Benzol or Alcohol.
For safety, keep product clean and free from dust.

Refer all servicing to qualified service personnel only.

Do not perform any servicing other than those instruc-
tions contained within the User's Manual.

Fuse

To prevent fire and damage to the product, use only 

No user serviceable parts inside.

Power Supply

Ensure that the mains source voltage (AC outlet) 
matches the voltage rating of the product. Failure 
to do so could result in damage to the product and 
possibly the user.

Unplug the product before electrical storms occur 
and when unused for long periods of time to reduce 
the risk of electric shock or fire.

External Connection

Always use proper ready-made insulated mains 
cabling (power cord). Failure to do so could result 
in shock/death or fire. If in doubt, seek advice from 
a registered electrician.

Do Not Remove Any Covers

Within the product are areas where high voltages 
may present. To reduce the risk of electric shock do 
not remove any covers unless the AC mains power 
cord is removed.

Covers should be removed by qualified service 
personnel only. 

WARNING

1

Disposing of this product should not be 
placed in municipal waste and should be  
Separate collection.

Содержание MP2D

Страница 1: ...User s Manual LTO R R www altoproaudio com Version 1 1 November 2005 English English MP2D TWO CHANNELS MICROPHONE INSTRUMENT PREAMPLIFIER WITH STEREO BUS ...

Страница 2: ...t away from naked flames Read these instructions Follow all instructions Keep these instructions Do not discard Heed all warnings Only use attachments accessories specified by the manufacturer Do not tamper with the power cord or plug These are designed for your safety Do not remove Ground connections If the plug does not fit your AC outlet seek advice from a qualified electrician Protect the powe...

Страница 3: ...United Kingdom and Taiwan The core of our digital audio products is a sophisticated Software Team for the last 7 years Following this idea we create our products and we will create the new ones From our side we guarantee you and we will guarantee you also in future the best quality the best fruits of our continuous researches and the best prices Nothing else to add but that we would like to thank ...

Страница 4: ...TABLE OF CONTENTS 1 INTRODUC ION T 4 2 FEATURES 4 3 CONTROL ELEMENTS 4 4 INSTALLATION AND CONNECTION 7 5 BLOCK DIAGRAM 8 6 TECHNICAL SPECIFICATION 9 7 WARRANTY 10 3 ...

Страница 5: ...allow the audio potential of an acoustic or electric instrument pickup to be fully realized Note please do not use the pre amp of the instrument on board if possible in order to avoid distortion caused by over driving the input signal Input Gain Control This pot can adjust the gain of the input signal The gain range can be varied from 0dB to 60dB Vintage Control This pot can be used to select the ...

Страница 6: ...t Level LED Display The highly accurate 12 segments LED meter indicates the level of the output signal When these two red LEDs flash it will warn you that the level of output signal is too high and may cause distortion please attenuate the level of the input signal or the output signal MASTER LEVEL Control This pot adjusts the output level of the Stereo Bus Channels are assigned to the bus via the...

Страница 7: ...urn the knob to 6 or 7 position WCLK IN Connector The WCLK IN is accessed through separate BNC connectors The WCLK IN scans the incoming information and automatically synchs to the necessary sample rate If you need to use EXT CLOCK please turn the sample rate knob to 6 or 7 position MAIN OUTPUT This stereo output is supplied with two XLR connectors for the RIGHT and LEFT output of the stereo main ...

Страница 8: ...shelf available from various rack manufactures or your music dealer The MP2D fits into one standard 19 rack unit of space Please allow at least an additional 4 depth for the connectors on the rear panel Be sure that there is enough air space around the unit for sufficient ventilation and please do not place the MP2D on high temperature devices such as power amplifiers etc to avoid overheating For ...

Страница 9: ...5 BLOCK DIAGRAM 8 ...

Страница 10: ...tage 0 5 vintage max 100dB 22Hz to 22Khz True RMS detection FUNCTION SWITCHES 48 Volt Phantom Power Polarity Reverse Rumble Filter Main L R bus selection Each channel of the MP2D has 48V Phantom power available A phase reverse switch is provided on each channel A Rumble fiter is provided on each channel for eliminating low frequency noise The MP2D has a stereo summing bus for combining the input s...

Страница 11: ...TO of 1 year from the purchase date if you have completed the Warranty Registration Card in time 3 3 During the warranty service may repair or replace this product at its own option at no charge to you for LTO parts or for labor in accordance with the right side of this limited warranty 3 4 This warranty does not apply to the damages to this product that occurred as the following conditions Normal...

Страница 12: ...13737 email alto altoproaudio com Fax 886 4 22346757 c All rights reserved to ALTO All features and content might be changed without prior notice Any photocopy translation or reproduction of part of this manual without written permission is forbidden Copyright 2005 SEIKAKU GROUP SEIKAKU TECHNICAL GROUP LIMITED ...

Отзывы: