Alto MISTRAL400 Скачать руководство пользователя страница 11

6. WARRANTY

1. WARRANTY REGISTRATION CARD

To obtain Warranty Service, the buyer should first fill out and return the enclosed Warranty Registration Card within
10 days of the Purchase Date.

All the information presented in this Warranty Registration Card gives the manufacturer a better understanding of
the sales status, so as to purport a more effective and efficient after-sales warranty service.

Please fill out all the information carefully and genuinely, miswriting or absence of this card will void your warranty
service.

2. RETURN NOTICE

2.1 In case of return for any warranty service, please make sure that the product is well packed in its original shipping

carton, and it can protect your unit from any other extra damage.

2.2 Please provide a copy of your sales receipt or other proof of purchase with the returned machine, and give detail

information about your return address and contact telephone number.

2.3 A brief description of the defect will be appreciated.

2.4 Please prepay all the costs involved in the return shipping, handling and insurance.

3. TERMS AND CONDITIONS

3.1

warrants that this product will be free from any defects in materials and/or workmanship for a period

LTO

of 1 year from the purchase date if you have completed the Warranty Registration Card in time.

3.3 During the warranty service,

may repair or replace this product at its own option at no charge to you for

LTO

parts or for labor in accordance with the right side of this limited warranty.

3.4 This warranty does not apply to the damages to this product that occurred as the following conditions:

Normal tear and wear.

Instead of operating in accordance with the user's manual thoroughly, any abuse or misuse of this product.

The product has been altered or modified in any way.

Damage which may have been caused either directly or indirectly by another product / force / etc.

Abnormal service or repairing by anyone other than the qualified personnel or technician.

And in such cases, all the expenses will be charged to the buyer.

3.5 In no event shall

be liable for any incidental or consequential damages. Some states do not allow the exclu-

LTO

sion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you.

3.6 This warranty gives you the specific rights, and these rights are compatible with the state laws, you may also

have other statutory rights that may vary from state to state.

3.2 The warranty service is only available to the original consumer, who purchased this product directly from the

retail dealer, and it can not be transferred.

10

Содержание MISTRAL400

Страница 1: ...MISTRAL400 STEREO POWER AMPLIFIER User s Manual LTO R www altoproaudio com Version 1 1 MAY 2005 English ...

Страница 2: ... flame sources such as lighted candles should be placed on the apparatus IMPORTANT SAFETY INSTRUCTIONS Read these instructions Heed all warnings Follow all instructions Keep these instructions Only use attachments accessories specified by the manu facturer Power Cord and Plug Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider tha...

Страница 3: ...omments ur job we d like to share with you our work and our dreams paying attention to your suggestions Following this idea we create our products and we will create the new ones From our side we guarantee you and we will guarantee you also in future the best quality and the best fruits of our continuous researches and the best prices Our LTO MISTRAL400 Stereo Power Amplifier is the result of many...

Страница 4: ...TABLE OF CONTENTS 1 INTRODUCTION 4 2 FEATURES 4 3 CONTROL ELEMENTS 5 3 1 The Front Panel 3 2 The Rear Panel 4 APPLICATION 7 4 1 Stereo Mode 5 TECHNICAL SPECIFICATIONS 9 6 WARRANTY 10 3 4 2 Bridge Mode ...

Страница 5: ...EIAJ The MISTRAL400 is a line of high power low profile professional Power Amplifiers with advanced features LTO and great reliability They deliver tremendous power in only one rack space providing high level performance under the most demanding conditions The amplifier frame contains all solid state circuitry using complementary silicon output devices The amplifier contains two independent channe...

Страница 6: ...N 2 RING PIN 3 SLEEVE PIN 1 CH1 1 1 POS NEG CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG 2 1 3 NEW TIDE 2 1 3 NEW TIDE CH2 CH1 Use only with a 250V fuse Rated Power Consumption 200W REPLACE FUSE WITH CORRECT TYPE ONLY Apparaten skall anslutas ansluts till ett natverk till jordat uttag nar den FUSE T1 6AL 250VAC AC INPUT 220 240V 50 60Hz 6 7 11 10 9 8 B rear Panel This is set for 110V AC TO 1...

Страница 7: ...oltage has been correctly set The fuse holder above the AC connector on the rear of the chassis has 3 triangular markers please refer to the above pictures with two of these triangles opposing each other your unit is set to the operating voltage printed next to these markers To change pull fuse holder out and rotate 180 then push in again 0 Fuse Holder Voltage Selector This is a dual voltage unit ...

Страница 8: ... NEG CH2 1 1 POS NEG 2 1 3 NEW TIDE 2 1 3 NEW TIDE CH2 CH1 Use only with a 250V fuse Rated Power Consumption 200W REPLACE FUSE WITH CORRECT TYPE ONLY Apparaten skall anslutas ansluts till ett natverk till jordat uttag nar den FUSE T1 6AL 250VAC AC INPUT 220 240V 50 60Hz 7 4 APPLICATION 4 1 Stereo Mode In this mode Channel 1 and Channel 2 operate independently just as traditional stereo amplifier T...

Страница 9: ... 1 2 3 GND INPUT CH2 INPUT CH1 POWER OUTPUTS LIMITER OFF ON TIP SP SP TIP SP SP MODE BRIDGE STEREO TIP PIN 2 RING PIN 3 SLEEVE PIN 1 TIP PIN 2 RING PIN 3 SLEEVE PIN 1 CH1 1 1 POS NEG CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG 2 1 3 NEW TIDE 2 1 3 NEW TIDE CH2 CH1 Use only with a 250V fuse Rated Power Consumption 200W REPLACE FUSE WITH CORRECT TYPE ONLY Apparaten skall anslutas ansluts till...

Страница 10: ...1 3dB 300 at 8ohms 102dB 40x 32dB 1Vrms 10Vrms 22dB 10K ohms unbalanced 20K ohms balanced 56 36dB FRONT AC SWITCH CH1 CH2 GAIN KNOBS On off muting DC fault load grounding relay Internal fault fuses 220 240 110 120 Vac 50 60Hz 19 48 3 cm rack mounting 1 7 4 4 cm tall 1 rack space 11 28 cm deep rack mounting to rear support ears 7 5Kg 60W 100W 180W Indicators 1 per channel Connectors each channel Lo...

Страница 11: ...TO of 1 year from the purchase date if you have completed the Warranty Registration Card in time 3 3 During the warranty service may repair or replace this product at its own option at no charge to you for LTO parts or for labor in accordance with the right side of this limited warranty 3 4 This warranty does not apply to the damages to this product that occurred as the following conditions Normal...

Страница 12: ... com Tel 886 4 22313737 email alto altoproaudio com Fax 886 4 22346757 c All rights reserved to ALTO All features and content might be changed without prior notice Any photocopy translation or reproduction of part of this manual without written permission is forbidden Copyright 2005 SEIKAKU GROUP SEIKAKU TECHNICAL GROUP LIMITED ...

Отзывы: