Alto Mistral 400 Скачать руководство пользователя страница 2

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

IMPORTANT SAFETY INSTRUCTION

TO REDUCE THE RISK OF ELECTRIC SHOCK
PLEASE DO NOT REMOVE THE COVER OR
THE BACK PANEL OF THIS EQUIPMENT.
THERE ARE NO PARTS NEEDED BY USER
INSIDE THE EQUIPMENT. FOR SERVICE,
PLEASE CONTACT QUALIFIED SERVICE
CENTERS.

WARNING

To reduce the risk of electric shock
and fire, do not expose this equipment
to moisture or rain.

1.
2.
3.

4.

5.

6.

7.

8.

9.

10.

Dispose of this product should
not be placed in municipal waste
and should be separate collection.

11.

12.

Move this Equipment only with a cart,
stand, tripod, or bracket,
specified by the
manufacturer, or
sold with the
Equipment. When
a cart is used, use
caution when
moving the cart /
equipment
combination to
avoid possible
injury from tip-over.
Permanent hearing loss may be caused by
exposure to \ extremely high noise levels.
The US. Government's Occupational Safety
and Health Administration (OSHA) has
specified the permissible exposure to noise
level.
These are shown in the following chart:

According to OSHA, an exposure to high SPL in
excess of these limits may result in the loss of
heat. To avoid the potential damage of heat, it is
recommended that Personnel exposed to
equipment capable of generating high SPL use
hearing protection while such equipment is
under operation.

This symbol, wherever used, alerts you to the
presence of un-insulated and dangerous voltages

within the product enclosure. These are voltages that
may be sufficient to constitute the risk of electric
shock or death.

This symbol, wherever used, alerts you to

important operating and maintenance instructions.

Please read.

Protective Ground Terminal
AC mains (Alternating Current)
Hazardous Live Terminal

ON:

Denotes the product is turned on.

OFF: Denotes the product is turned off.

The apparatus shall be connected to a mains
socket outlet with a protective earthing
connection.

The mains plug or an appliance coupler is used
as the disconnect device, the disconnect device
shall remain readily operable.

CAUTION

Describes precautions that should be observed to
prevent damage to the product.

Read this Manual carefully before operation.
Keep this Manual in a safe place.
Be aware of all warnings reported
with this symbol.
Keep this Equipment away from water and
moisture.
Clean it only with dry cloth. Do not use
solvent or other chemicals.
Do not damp or cover any cooling opening.
Install the equipment only in accordance with
the Manufacturer's instructions.

Power Cords are designed for your safety. Do
not remove Ground connections! If the plug
does not fit your AC outlet, seek advice from
a qualified electrician. Protect the power
cord and plug from any physical stress to
avoid risk of electric shock. Do not place
heavy objects on the power cord. This could
cause electric shock or fire.

Unplug this equipment when unused for long
periods of time or during a storm.

Refer all service to qualified service personnel
only. Do not perform any servicing other than
those instructions contained within the
User's Manual.

To prevent fire and damage to the product,
use only the recommended fuse type as
indicated in this manual. Do not short-circuit
the fuse holder. Before replacing the fuse,
make sure that the product is OFF and
disconnected from the AC outlet.

HOURS X DAY

EXAMPLE

8
6
4
3
2
1,5
1
0,5
0,25 or less

SPL

90
92
95
97

100
102
105
110
115

Small gig
train
Subway train
High level desktop monitors
Classic music concert

Rock concert

Содержание Mistral 400

Страница 1: ...User s Manual www altoproaudio com Version 1 0 NOV 2007 LTO R English STEREO POWER AMPLIFIER MISTRAL 400 ...

Страница 2: ...ective Ground Terminal AC mains Alternating Current Hazardous Live Terminal ON Denotes the product is turned on OFF Denotes the product is turned off The apparatus shall be connected to a mains socket outlet with a protective earthing connection The mains plug or an appliance coupler is used as the disconnect device the disconnect device shall remain readily operable CAUTION Describes precautions ...

Страница 3: ...er connectors and all the inputs are electronically balanced LED indicators for limit power on and clip Enjoy your MISTRAL 400 and make sure to read this Manual carefully before operation 2 FEATURES Mountable in a 19 unit 1U stereo high power amplifier Fantastic audio quality even with extremely high volume levels Solid and durable can be mounted into a cabinet User controllable clip limiter 2 100...

Страница 4: ...ts up This means the output level of signal source is too high and it is time to reduce the input level until the LED turns off 3 OUTPUT LIMITER LED When the unit limits the output signal the LED lights up 4 POWER LED This LED lights up when the unit is powered on LEVEL CONTROLS For CH 1 CH 2 Adjust the output signal level to avoid signal distortion 5 2 3 1 4 5 LTO R 5 ...

Страница 5: ... a fuse of the correct type only Rear panel MODE SELECTOR The MISTRAL 400 power amplifier presents two operating modes Stereo Mode In this mode CH 1 and CH 2 operate independently as a normal stereo amplifier The CH 1 input signal will be output from the CH 1 output connector and CH 2 input signal will be output from the CH 2 output connector Bridge Mode In this mode CH 1 input signal will be outp...

Страница 6: ...en Class two wiring Class two wiring 4 Input Connector Balanced 1 2 3 GND INPUT Stereo Mode Release this button CH 1 4 APPLICATION The MISTRAL 400 amplifier provides two operating modes stereo mode and bridge mode you can decide each specific operating mode according to your actual application circumstance Please see following diagram for connecting the power amplifier into your audio system Stere...

Страница 7: ...TEREO TIP PIN 2 RING PIN 3 SLEEVE PIN 1 TIP PIN 2 RING PIN 3 SLEEVE PIN 1 CH1 1 1 POS NEG CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG 2 1 3 NEW TIDE 2 1 3 NEW TIDE CH2 CH1 AC INPUT 110 120V 50 60Hz FUSE T3 15AL 250VAC Rated Power Consumption 200W REPLACE FUSE WITH CORRECT TYPE ONLY Apparaten skall anslutas ansluts till ett natverk till jordat uttag nar den Class two wiring Class two wiring ...

Страница 8: ...anced 1 2 3 GND INPUT CH 1 CH 1 Bridge Mode Press this button CH 2 CH2 INPUT CH1 POWER OUTPUTS LIMITER OFF ON TIP SP SP TIP SP SP MODE BRIDGE STEREO TIP PIN 2 RING PIN 3 SLEEVE PIN 1 TIP PIN 2 RING PIN 3 SLEEVE PIN 1 CH1 1 1 POS NEG CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG 2 1 3 NEW TIDE 2 1 3 NEW TIDE CH2 CH1 AC INPUT 110 120V 50 60Hz FUSE T3 15AL 250VAC Rated Power Consumption 200W REP...

Страница 9: ......

Страница 10: ...iod of 1 year from the purchase date if you have completed the Warranty Registration Card in time 3 2 The warranty service is only available to the original consumer who purchased this product directly from the retail dealer and it can not be transferred 3 3 During the warranty service may repair or replace this product at its LTO own option at no charge to you for parts or for labor in accordance...

Страница 11: ...py translation or reproduction of part of this manual without written permission is forbidden Copyright 2007 Seikaku Group SEIKAKU TECHNICAL GROUP LIMITED NO 1 Lane 17 Sec 2 Han Shi West Road Taichung 40151 Taiwan http www altoproaudio com Tel 886 4 22313737 email alto altoproaudio com Fax 886 4 22346757 ...

Отзывы: