![Alto ENCORE R Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/alto/encore-r/encore-r_electrical-troubleshooting-manual_2911787005.webp)
1-4
American-Lincoln Technology
ENCORE R Troubleshooting Guide
DRIVE MOTOR REVERSE
DRIVE MOTOR REVERSE
Conditions necessary for circuit to work
1.
Battery voltage 36VDC
2.
Key switch on
3.
CB-4&5, FU1 closed
4.
4 - Solenoids 1A & 5 closed
5
5.
Seat switch closed
36 V BATTERY BANK
CB-5
CB-4
70 AMP
REV. MTR. SOL.
THE SEAT SWITCH JUMPS FROM
THE REV. SOL. TO 1A AND THEN
TO THE FWD. SOL.
FU-1
10 AMP
10 AMP
11
9A
9A
9B
9
11
7K
7K
11
11A
7,7C,7H,
77,77C,77D
2
3
12
12
25A
25V
25W
25W
25Y
25Y
25Y
25V
1T
1
1,1A,1B
A
B
A
M
3
25F
25G
25A
BATT.
IGN.
ACC
5B
NEW MODULE
12
11
16
1A
1A
SEAT
SW.
B+
25
25
25
19
C
C
C
C
D
M
ET-103
W/BRN.
GRN.
ORG.
BLK.
BLK./WHT
WHT
REV.
5
19
39
38
17
17
8
16
9
1
S1
5A
FIELD
S2
A1
A1
A2
A1
2+ HP
DRIVE MTR.
ARM
16 PIN
1207-1141
M-
B-
B+ A2
T0201/0002
T201