Page -24-
CLARKE TECHNOLOGY Operator's Manual -Encore S2426/L2426
Maintenance cont.
Figure 35
3. Turn the key switch "OFF" and remove the key.
4. Tip up the recovery tank until it locks in the full open
position.
5. Go to the front of the machine and unlatch the front
cover and swing cover open.
6. Locate the four mounting studs on the brush head
bracket. See figure 35. The top two mounting nuts
can be accessed through the top of the solution
tank. The lower two can be accessed through the
front. Loosen the four mounting nuts 2 to 3 turns
counterclockwise. NOTE: Do not remove mounting
nuts.
7. The brush head assembly can slide to the right side
by one inch or placed back into the center. Slide the
brush head assembly all the way to the ends of the
slots for the desired position. This insures that the
head operates straight up and down.
8. After repositioning the brush head, tighten nuts
securely to approximately 236 inch-lbs.
9. Close the front cover.
10. Close the recovery tank.