Alto DPA 2500 Скачать руководство пользователя страница 2

1

SAFETY RELATED SYMBOLS

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

This symbol, wherever used, alerts you to the pre-
sence of un-insulated and dangerous voltages with-
in the product enclosure. These are voltages that
may be sufficient to constitute the risk of electric
shock or death.

Protective Ground Terminal

AC mains (Alternating Current)

Hazardous Live Terminal

ON:

Denotes the product is turned on.

This symbol, wherever used, alerts you to impo-
rtant operating and maintenance instructions.
Please read.

OFF:

Denotes the product is turned off.

WARNING

Describes precautions that should be observed to
prevent the possibility of death or injury to the user.

CAUTION

Describes precautions that should be observed to
prevent damage to the product.

Power Supply

Ensure that the mains source voltage (AC outlet)
matches the voltage rating of the product. Failure
to do so could result in damage to the product and
possibly the user.

Unplug the product before electrical storms occur
and when unused for long periods of time to reduce
the risk of electric shock or fire.

External Connection

Always use proper ready-made insulated mains
cabling (power cord). Failure to do so could result
in shock/death or fire. If in doubt, seek advice from
a registered electrician.

Do Not Remove Any Covers

Within the product are areas where high voltages
may present. To reduce the risk of electric shock do
not remove any covers unless the AC mains power
cord is removed.

Covers should be removed by qualified service
personnel only.

No user serviceable parts inside.

Fuse

To prevent fire and damage to the product, use only

the recommended fuse type as indicated in this
manual. Do not short-circuit the fuse holder. Before
replacing the fuse, make sure that the product is
OFF and disconnected from the AC outlet.

Protective Ground

Before turning the product ON, make sure that it is
connected to Ground. This is to prevent the risk of
electric shock.

Never cut internal or external Ground wires. Likewise,
never remove Ground wiring from the Protective
Ground Terminal.

Operating Conditions

Always install in accordance with the manufacturer's
instructions.

To avoid the risk of electric shock and damage, do
not subject this product to any liquid/rain or moisture.
Do not use this product when in close proximity to
water.

Do not install this product near any direct heat source.

Do not block areas of ventilation. Failure to do so
could result in fire.

Keep product away from naked flames.

IMPORTANT SAFETY INSTRUCTIONS

Read these instructions

Follow all instructions

Keep these instructions. Do not discard.

Heed all warnings.

Only use attachments/accessories specified by the
manufacturer.

Power Cord and Plug

Do not tamper with the power cord or plug. These are
designed for your safety.

Do not remove Ground connections!

If the plug does not fit your AC outlet seek advice from
a qualified electrician.

Protect the power cord and plug from any physical
stress to avoid risk of electric shock.

Do not place heavy objects on the power cord. This
could cause electric shock or fire.

Cleaning

When required, either blow off dust from the product
or use a dry cloth.

Do not use any solvents such as Benzol or Alcohol.
For safety, keep product clean and free from dust.

Servicing

Refer all servicing to qualified service personnel only.

Do not perform any servicing other than those instruc-
tions contained within the User's Manual.

WARNING

Содержание DPA 2500

Страница 1: ...40 BIT ENHANCED STEREO POWER AMPLIFIER DPA 2500 4000 User s Manual LTO R www altoproaudio com Version 1 0 September 2004 English ...

Страница 2: ...y the recommended fuse type as indicated in this manual Do not short circuit the fuse holder Before replacing the fuse make sure that the product is OFF and disconnected from the AC outlet Protective Ground Before turning the product ON make sure that it is connected to Ground This is to prevent the risk of electric shock Never cut internal or external Ground wires Likewise never remove Ground wir...

Страница 3: ...reliable and high quality product ready for all your venues And thanks to their passion for music and professional audio it has been possible for us to offer you our most important team member our continued support too Our LTO DPA2500 4000 Stereo Power Amplifier is the result of many hours of listening and tests involving common people area experts musicians and technicians The result of this effo...

Страница 4: ...ESCRIPTION 3 4 1 Preset Selection 4 2 Edit Menu 4 3 Channel Selection 4 4 Comm Selection 4 5 SIG LIMITER LED 5 1 How to set the DPA s ID number 5 2 Connection to the PC 5 3 First Steps with the PC Editor 5 4 Edit Mode Password Protection 5 5 Help File 5 6 Introduction to the PC Editor 8 12 CONNECTIONS 9 13 APPLICATION 10 17 TECHNICAL SPECIFICATIONS 11 WARRANTY 18 9 1 Stereo Mode 9 2 Bridge Mode ...

Страница 5: ...es power supplies and protection system All protection systems except the main AC one are self resetting upon removal of fault and the remaining channels shall continue to operate Each channel has independent protective circuitry against open circuit short circuit mismatched loads and over temperature Thanks to the use of selected and expensive components the performance of DPA2500 4000 is worth m...

Страница 6: ...l of channel 1 and channel 2 separately 14 Balanced Input Connectors These two output connectors are paralleled inside with the two input connectors It enables the unit to work under paralleled mode Please also refer to wiring diagram for paralleled mode 15 Parallel Output Connectors 16 Mode Selector Total two optional modes Up for Stereo mode Down for Bridge mode Stereo Mode In this mode channel ...

Страница 7: ...o amplifier and PC via connecting the DPA2500 4000 stereo amplifier to a PC all the processor functions are possible to be controlled remotely by ALTO editing software 17 Fan 6 4 GETTING STARTED Switching on the DPA2500 4000 after an initialization procedure the last selected preset and settings will be loaded the number of last preset will appear on the display 4 1 Preset Selection There are tota...

Страница 8: ...or will be lighting all the time if you set this function ON and it effects only on the selected channels 4 4 Comm Selection It sets the ID number of the unit 1 in the default condition 32 available be Select COMM using SELECT key the COMM indicator lights up and the last selected ID number will displayed Use UP DOWN keys to set the new ID number Press ENTER key to confirm the new ID number 4 5 SI...

Страница 9: ...BRIDGE STEREO CH1 OUTPUT1 OUTPUT2 POWER OUTPUTS CH1 1 1 POS NEG CH2 BRIDGE MONO CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG BREAKER INPUT INPUT TIP PIN 2 RING PIN 3 SLEEVE PIN 1 TIP PIN 2 RING PIN 3 SLEEVE PIN 1 INPUT INPUT 2 1 2 1 3 2 1 2 1 3 RS485 IN RS485 OUT RS232 SERIAL PORT 5 2 Connection to the PC Connect the First DPA to the PC s RS232 serial port using a 9 pin female plug connected...

Страница 10: ...sh to overwrite the current data in the then you DPA unit must initiate a new session by closing the current window and then selecting NETWORK SCAN File New DPA unit DPA unit Network Scan so that the uploads to the PC Every time an upload is made all the USER PRESETS stored in the are transferred to the DPA unit correspo nding numbered presets within the PC Editor Select NETWORK SCAN The program w...

Страница 11: ...lained in more detail in the next sec tion 1 NOTCH You can turn on or off the dynamic notch filter and adjust its parameters 2 NOISE GATE You can set the DPA unit to cut the signal if it falls below a certain level Most often used to cut the back ground noise between music tracks 3 COMP It s a multi band compressor allowing you determine the amout of level gain ie incnease in volume above a thresh...

Страница 12: ...RESSOR LIMITER parameters to be set In addition in this page the output levels and the LIMITER action are displayed GLOBAL this windows shows the response curves of the system s outputs 7 WORKING WITH PRESETS At the lower edge of the PC Editor window is a series of commands for recalling and storing PRESETS To load a PRESET Click on and then on one of the numbered red FACTORY or green USER PRESET ...

Страница 13: ...les and some connection examples referred to various system configurations Inputs A B RS485 IN 3 1 2 GROUND HOT COLD Inputs A B GROUND HOT COLD RING SLEEVE TIP BALANCED XLR M BALANCED JACK RS232 RS232 9 Pin Parsllel Output Connectors RS485 OUT GROUND HOT COLD 3 2 1 BALANCED XLR F ...

Страница 14: ...RALLEL OUTPUT LIMITER OFF ON CH2 BALANCED INPUT PARALLEL OUTPUT MODE BRIDGE STEREO CH1 OUTPUT1 OUTPUT2 POWER OUTPUTS CH1 1 1 POS NEG CH2 BRIDGE MONO CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG BREAKER INPUT INPUT TIP PIN 2 RING PIN 3 SLEEVE PIN 1 TIP PIN 2 RING PIN 3 SLEEVE PIN 1 INPUT INPUT ...

Страница 15: ...lease Input Connector Input Connector 1 2 3 GND INPUT Balanced Channel 2 Channel 1 Channel 1 MODE this button Release You can also operate the paralleled mode via outside wiring so the signal input from channel 1 or 2 will beo from both channel 1 and channel 2 simultaneously The volume of channel 1 or channel 2 can be contr tuput olled separately Apparaten skall anslutas till jordat uttag nar den ...

Страница 16: ...E MONO CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG BREAKER INPUT INPUT TIP PIN 2 RING PIN 3 SLEEVE PIN 1 TIP PIN 2 RING PIN 3 SLEEVE PIN 1 INPUT INPUT 2 1 2 1 3 2 1 2 1 3 RS485 IN RS485 OUT RS232 SERIAL PORT Apparaten skall anslutas till jordat uttag nar den ansluts till ett natverk CH1 BALANCED INPUT PARALLEL OUTPUT LIMITER OFF ON CH2 BALANCED INPUT PARALLEL OUTPUT MODE BRIDGE STEREO CH1 O...

Страница 17: ...ced Channel 2 Channel 1 Channel 1 MODE Press this button 9 2 Bridge Mode In this mode the signal input into channel 1 will be output from the bridged end on the other hand the output level control of channel 2 should be turn down to smallest turn the volume control at counterclockwise Only the volume control of channel 1 is used to control the volume of whole system Apparaten skall anslutas till j...

Страница 18: ...0K ohms balanced 56 36dB FRONT AC SWITCH CH1 2 GAIN KNOBS DSP controls REAR LIMITER BRIDGE SELECTOR Continuously variable speed fan rear to front air flow On off muting DC fault load grounding relay Internal fault fuses 200 240 100 120 Vac 50 60Hz 460W 625W 830W 1000W 1400W 2000W Indicators 1 per channel Connectors each channel Cooling Load Protection Power Requirements Dimensions Net Weight Power...

Страница 19: ...TO riod of 1 year from the purchase date if you have completed the Warranty Registration Card in time 3 3 During the warranty service may repair or replace this product at its own option at no charge to you for LTO parts or for labor in accordance with the right side of this limited warranty 3 4 This warranty does not apply to the damages to this product that occurred as the following conditions N...

Страница 20: ...w altoproaudio com Tel 886 4 22313737 email alto altoproaudio com Fax 886 4 22346757 All rights reserved to ALTO All features and content might be changed prior notice Any photocopy translation or reproduction of part of this written permission is forbidden Copyright 2004 S without manual without ekaku Electron c ...