E L E C T R I C A L

VOLTAGE

PHASE

CYCLE

/

HZ

AMPS

kW

CORD AND PLUG

208-240

(

AGENCY

)

1

60

28.8

6.0

NO CORD

at 208

1

60

28.9

6.0

OR PLUG

at 240

1

60

22.2

5.3

230

1

50

21.3

4.9

NO CORD OR PLUG

The appliance must be installed by a qualified

service technician. The oven must be properly

grounded in accordance with the National Electrical

Code and applicable local codes.
Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is

easily accessible in case of an emergency. Arcing

will occur when connecting or disconnecting the

unit unless all controls are in the “

OFF

” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed by

a licensed electrician in accordance with applicable

local electrical codes.
750- and 1000-TH-II models at 208-240V are dual

rated units with a conversion switch mounted

under an access cover on the rear of the oven, near

the power cord.
With the voltage conversion switch in the 200-208V

(UPPER) position, the oven will function properly

with a source voltage of between 200 and 208.
With the voltage conversion switch in the 220-240V

(LOWER) position, the unit will function properly

with a source voltage of between 220 and 240.

NOTE:

ALL 208-240V units are shipped from the

factory with the voltage conversion switch

in the 220-240 position.

All 125V rated units will function properly with a

source voltage of between 100 and 125, 60 Hz.
The 125V rated units are provided with a cord and

plug [NEMA #5-20P]. Have a licensed electrician

install the proper outlet configuration as required

for the unit in accordance with applicable, local

electrical codes. This will assure a safe and trouble-

free installation.

230V:

To prevent an electrical shock hazard between

the appliance and other appliances or metal parts

in close vicinity, an equalization-bonding stud is

provided. An equalization bonding lead must be

connected to this stud and the other appliances /

metal parts to provide sufficient protection

against potential difference. The terminal is

marked with the following symbol.

NOTE:

230V appliances must be connected to an

electrical circuit that is protected by an

external GFCI outlet.

Ensure that the voltage conversion switch position

and the available power source match.

E L E C T R I C A L C O N N E C T I O N

I N S T A L L A T I O N

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

D A N G E R

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

All manuals and user guides at all-guides.com

Содержание EcoSmart 1000-TH-I

Страница 1: ...58 8744 USA CANADA FAX 262 251 7067 800 329 8744 U S A ONLY www alto shaam com MN 28636 11 08 P R I N T E D I N U S A C o o k i n g H o l d i n g O v e n M a n u a l C o n t r o l Model 1000 TH I INST...

Страница 2: ...the equipment model Contact the Alto Shaam service department if you have any questions concerning installation operation or maintenance NOTE All claims for warranty must include the full model number...

Страница 3: ...information that is important but not hazard related C A U T I O N Used to indicate the presence of a hazard that can or will cause minor personal injury property damage or a potential unsafe practic...

Страница 4: ...se laden vapor resulted in a total of 0 55 milligrams per cubic meter with no visible smoke and is considered representative of all oven models in the line Based on these results hood installation and...

Страница 5: ...EST 400 lb 181 kg 440 lb 200 kg PRODUCT PAN CAPACITY PER COMPARTMENT 120 lb 54 kg MAXIMUM VOLUME MAXIMUM 60 QUARTS 76 LITERS I N S TA L L AT I O N OPTIONS ACCESSORIES Bumper Full Perimeter 5005103 Car...

Страница 6: ...mproper function and will result in the uneven baking with products consisting of semi liquid batter RESTRAINT REQUIREMENTS MOBILE EQUIPMENT Any appliance that is not furnished with a power supply cor...

Страница 7: ...ON INSTRUCTIONS DRIP TRAY INSTALLATION INSTRUCTIONS S I T E I N S TA L L AT I O N SEE ALTO SHAAM PARTS LIST FOR ALTO SHAAM PART NUMBERS I N S TA L L AT I O N WA R N I N G FAILURE TO PROPERLY INSTALL T...

Страница 8: ...ated units will function properly with a source voltage of between 100 and 125 60 Hz The 125V rated units are provided with a cord and plug NEMA 5 20P Have a licensed electrician install the proper ou...

Страница 9: ...the oven Insert the drip pan on the interior bottom surface of the oven 2 Close the oven doors press the power switch to the on position and set the thermostat to 300 F 149 C 3 Allow the oven to cycle...

Страница 10: ...These instructions are basic operational guidelines only For complete instructions see A Guide to Low Temperature Cooking and Holding by HALO HEAT packed with the oven COOKING OVEN CHARACTERISTICS The...

Страница 11: ...1 to 2 minutes must be the only time period allowed for the initial heat to be released from the product Most Halo Heat Holding Equipment is provided with a thermostat control between 60 and 200 F 16...

Страница 12: ...and the area wiped as soon as possible but at the very least a minimum of once a day Always thoroughly rinse surfaces after using a cleaning agent and wipe standing water as quickly as possible after...

Страница 13: ...ry with a clean cloth or air dry Leave doors open until interior is completely dry Replace side racks and shelves 9 Wipe door gaskets and control panel dry with a clean soft cloth 10 Interior can be w...

Страница 14: ...e method of measuring safe temperatures of both hot and cold foods is by internal product temperature A quality thermometer is an effective tool for this purpose and should be routinely used on all pr...

Страница 15: ...re consequently any bending of the bulb results in a change in its volume and alters the accuracy of the thermostat calibration A thermostat should be checked or recalibrated by placing a quality ther...

Страница 16: ...lace thermostat hold calibration Oven goes from cooking Hold thermostat Replace hold thermostat temperature to cold Oven will not go into cook cycle Timer or contactor With timer turned ON line when t...

Страница 17: ...E 26692 Control Panel Bezel PE 26567 Door Assembly 15415 Drip Tray 1007588 Door Gasket GS 22952 Door Handle HD 27080 Door Hinge HG 22338 Panel Side 1004985 Std 1003742 HD Shelf SH 2325 Side Rack SR 22...

Страница 18: ...PE 26692 Door Assembly RIGHT HAND LEFT HAND 2 15415 15721 Drip Pan 2 14824 Drip Tray 1 1007588 Gasket Door 2 GS 22952 Gauge Temperature 2 GU 34197 Handle Door 2 HD 27080 Hinge Door 2 pair HG 22338 Ind...

Страница 19: ...old Indicator Light LI 3951 Fan Box FA 3974 Contactor CN 3052 Contactor CN 3052 Top Unit Front Thermostat Cook TT 3329 Thermostat Hold TT 3057 Terminal Block Power BK 3019 Switch Voltage SW 3528 Switc...

Страница 20: ...HEATING SERVICE KIT 4881 ON E KIT P E R C A BIN E T C OMP A RTME N T S E R V I C E DESCRIPTION QTY PART NO Contactor 2 CN 3052 Fan Box 2 FA 34524 Ground Screw 1 SC 2190 Heat Sink 2 1005836 Indicator...

Страница 21: ...PG 20 1000 TH I INSTALLATION OPERATION SERVICE MANUAL All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 22: ...1000 TH I INSTALLATION OPERATION SERVICE MANUAL PG 21 All manuals and user guides at all guides com...

Страница 23: ...hs from the shipping date whichever occurs first THIS WARRANTY DOES NOT APPLY TO 1 Calibration 2 Replacement of light bulbs and or the replacement of display case glass due to damage of any kind 3 Equ...

Отзывы: