T
ROUBLESHOOTING
Converge®
▪
Service Manual
▪
M N-47241
▪
Rev 1
▪
6/22
74
The Fan Indicator Light is On
Inspect the cooling fan filters on the back of the oven.
Are the filters clean and airflow unobstructed?
No
Clean the cooling fan filters and
remove any obstructions.
Yes
Check the system cooling fans. Are they all running?
No
Determine cause of the fan motor(s)
not running and repair. See
troubleshooting tree for Axial
cooling fans.
Yes
With all panels on the oven, take a temperature
reading of the electrical compartment. Is the
temperature staying below130°F / 54°C?
No
Check the environment for causes
of excessive heat in the control area.
The oven must not be installed in
any area where it may be affected
by steam, grease, dripping water,
high temperature, or any other
adverse conditions.
Yes
Replace the bi-metal cooling fan indicator switch.