Alto-Shaam COMBITOUCH SERIES 6 10ESG Скачать руководство пользователя страница 2

#470 - 12/07

D U E TO O N G O I N G P R O D U C T I M P R O V E M E N T

S P E C I F I C AT I O N S A R E S U B J E C T TO C H A N G E W I T H O U T N O T I C E

.

www.alto-shaam.com

G A S   C O M B I N AT I O N   OV E N / S T E A M E R  

6

10

ES

G

C A PA C I T Y

FULL-SIZE PANS: 20" x 12" x 2-1/2"

Six (6)

Four (4)

GN 1/1: 530 x 325 x 65mm

Six (6)

Four (4)

HALF-SIZE SHEET PANS:* 18" x 13" x 1"

Six (6)

Five (5)

ON WIRE SHELVES ONLY

72 lb (33 kg) 

MAXIMUM

VOLUME MAXIMUM

:  45 

QUARTS

(57

LITERS

)

C L E A R A N C E   R E Q U I R E M E N T S

LEFT

: 6" (152mm)

PLUS SERVICE ACCESS

:  

18" (457mm)

RECOMMENDED

20" (508mm)

F R O M H E AT P R O D U C I N G E Q U I P M E N T

RIGHT

: 4" (102mm)

BACK

: 4" (102mm)

COUNTER

-

TOP INSTALLATIONS MUST MAINTAIN

4" (102mm)

MINIMUM CLEARANCE FROM THE COUNTER SURFACE

.

G A S   R E Q U I R E M E N T S

CONNECTED ENERGY LOAD

:

45,000 Btu/hr

HOOK

-

UP

:

3/4" NPT

MINIMUM CONNECTED PRESSURE

:

4.5" W.C. 

(Natural Gas)

8" W.C. 

(Propane)

MAXIMUM CONNECTED PRESSURE

:

14" W.C.

GAS TYPE MUST BE SPECIFIED ON ORDER

.

W E I G H T

NET

377 lb 

EST

.

(171 kg) 

EST

.

SHIP

442 lb 

EST

.

(200 kg) 

EST

.

CRATE

40" 

X

45" 

X

40" 

EST

.

DIMENSIONS

:

(1016 x 1143 x 1016mm)

E L E C T R I C A L

6 • 1 0

E S

G

6 • 1 0

E S

G / s k

VOLTAGE

PHASE

CYCLE

/

HZ

AWG

AMPS

kW

AMPS

kW

110 - 120

1

50/60

2 Wire plus ground, AWG 12

5.7

0.68

9.5

1.14

OTHER VOLTAGES AVAILABLE

:  Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz

WAT E R   R E Q U I R E M E N T S

TWO (2) COLD WATER INLETS - DRINKING QUALITY

ONE

(1)

TREATED WATER INLET

:

3/4" NPT

ONE

(1)

UNTREATED WATER INLET

:

3/4" NPT

LINE PRESSURE

:

30 to 90 psi

2.8 to 6.2 bar

REFER TO PUBLISHED SPECIFIC WATER REQUIREMENTS

WATER DRAIN:

1-1/2"

FERNCO CONNECTION WITH AIR GAP

I N S TA L L AT I O N   R E Q U I R E M E N T S

Oven must be installed level.
Hood installation.
Water supply shut-off valve and back-flow preventer.
Alternate burner orifice is required for installation

sites at elevations of 3,000 feet (914m) above sea level.

5-1/2"  (140mm)

Steam

Vent

(Top)

Untreated Water Intake (Bottom)

Treated Water Intake (Bottom)

Electrical

Connection (Bottom)

Gas Connection

(Bottom)

2" (50mm)

47-5/16" (1201mm)

42-1/16" (1068mm)

40-1/8"

(1018mm)

37" (939mm)

34-5/16"

(871mm)

Water Drain

(Bottom)

21-11/16"

(550mm)

5-1/2" 

(140mm)

25"

(635mm)

7-1/2"

(191mm)

5

8

-3

/1

6

(1

4

7

8

m

m

)

6

-1

/4

 (

1

5

9

m

m

)

5

(1

2

5

m

m

)

3

-1

/1

6

"

(7

6

m

m

)

2

7

-3

/4

"

(7

0

4

m

m

)

3

4

 (

8

6

3

m

m

)

2

-3

/8

 (

6

0

m

m

)

1

0

-5

/8

"

(2

7

0

m

m

)

1

9

-3

/8

"

(4

9

2

m

m

)

11-1/2"  (292mm)

3-5/8"

(92mm)

15-5/8"
(396mm)
Water Drain
(Side Back)

D I M E N S I O N S :

H x W x D

EXTERIOR

:

34" x 42-1/16" x 37"  (863mm x 1068mm x 939mm)

EXTERIOR

 

WITH

 

RETRACTABLE

 

DOOR

:

34" x 46-1/16" x 37"  (863mm x 1170mm x 939mm)

INTERIOR

:

17-3/4" x 17-3/8" x 26-13/16"  (450mm x 440mm x 680mm)

TOP

: 20" (508mm)

FOR AIR MOVEMENT

BOTTOM

: 5-1/8" (130mm) 

FOR LEGS

*

ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY

Отзывы: