![Alto-Shaam COMBITOUCH SERIES 6 10ESG Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/alto-shaam/combitouch-series-6-10esg/combitouch-series-6-10esg_specifications_2912661002.webp)
#470 - 12/07
D U E TO O N G O I N G P R O D U C T I M P R O V E M E N T
,
S P E C I F I C AT I O N S A R E S U B J E C T TO C H A N G E W I T H O U T N O T I C E
.
www.alto-shaam.com
G A S C O M B I N AT I O N OV E N / S T E A M E R
6
10
ES
G
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2"
Six (6)
Four (4)
GN 1/1: 530 x 325 x 65mm
Six (6)
Four (4)
HALF-SIZE SHEET PANS:* 18" x 13" x 1"
Six (6)
Five (5)
ON WIRE SHELVES ONLY
72 lb (33 kg)
MAXIMUM
VOLUME MAXIMUM
: 45
QUARTS
(57
LITERS
)
C L E A R A N C E R E Q U I R E M E N T S
LEFT
: 6" (152mm)
PLUS SERVICE ACCESS
:
18" (457mm)
RECOMMENDED
20" (508mm)
F R O M H E AT P R O D U C I N G E Q U I P M E N T
RIGHT
: 4" (102mm)
BACK
: 4" (102mm)
COUNTER
-
TOP INSTALLATIONS MUST MAINTAIN
4" (102mm)
MINIMUM CLEARANCE FROM THE COUNTER SURFACE
.
G A S R E Q U I R E M E N T S
CONNECTED ENERGY LOAD
:
45,000 Btu/hr
HOOK
-
UP
:
3/4" NPT
MINIMUM CONNECTED PRESSURE
:
4.5" W.C.
(Natural Gas)
8" W.C.
(Propane)
MAXIMUM CONNECTED PRESSURE
:
14" W.C.
GAS TYPE MUST BE SPECIFIED ON ORDER
.
W E I G H T
NET
377 lb
EST
.
(171 kg)
EST
.
SHIP
442 lb
EST
.
(200 kg)
EST
.
CRATE
40"
X
45"
X
40"
EST
.
DIMENSIONS
:
(1016 x 1143 x 1016mm)
E L E C T R I C A L
6 • 1 0
E S
G
6 • 1 0
E S
G / s k
VOLTAGE
PHASE
CYCLE
/
HZ
AWG
AMPS
kW
AMPS
kW
110 - 120
1
50/60
2 Wire plus ground, AWG 12
5.7
0.68
9.5
1.14
OTHER VOLTAGES AVAILABLE
: Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE
(1)
TREATED WATER INLET
:
3/4" NPT
ONE
(1)
UNTREATED WATER INLET
:
3/4" NPT
LINE PRESSURE
:
30 to 90 psi
2.8 to 6.2 bar
REFER TO PUBLISHED SPECIFIC WATER REQUIREMENTS
WATER DRAIN:
1-1/2"
FERNCO CONNECTION WITH AIR GAP
I N S TA L L AT I O N R E Q U I R E M E N T S
Oven must be installed level.
Hood installation.
Water supply shut-off valve and back-flow preventer.
Alternate burner orifice is required for installation
sites at elevations of 3,000 feet (914m) above sea level.
5-1/2" (140mm)
Steam
Vent
(Top)
Untreated Water Intake (Bottom)
Treated Water Intake (Bottom)
Electrical
Connection (Bottom)
Gas Connection
(Bottom)
2" (50mm)
47-5/16" (1201mm)
42-1/16" (1068mm)
40-1/8"
(1018mm)
37" (939mm)
34-5/16"
(871mm)
Water Drain
(Bottom)
21-11/16"
(550mm)
5-1/2"
(140mm)
25"
(635mm)
7-1/2"
(191mm)
5
8
-3
/1
6
"
(1
4
7
8
m
m
)
6
-1
/4
"
(
1
5
9
m
m
)
5
"
(1
2
5
m
m
)
3
-1
/1
6
"
(7
6
m
m
)
2
7
-3
/4
"
(7
0
4
m
m
)
3
4
"
(
8
6
3
m
m
)
2
-3
/8
"
(
6
0
m
m
)
1
0
-5
/8
"
(2
7
0
m
m
)
1
9
-3
/8
"
(4
9
2
m
m
)
11-1/2" (292mm)
3-5/8"
(92mm)
15-5/8"
(396mm)
Water Drain
(Side Back)
D I M E N S I O N S :
H x W x D
EXTERIOR
:
34" x 42-1/16" x 37" (863mm x 1068mm x 939mm)
EXTERIOR
WITH
RETRACTABLE
DOOR
:
34" x 46-1/16" x 37" (863mm x 1170mm x 939mm)
INTERIOR
:
17-3/4" x 17-3/8" x 26-13/16" (450mm x 440mm x 680mm)
TOP
: 20" (508mm)
FOR AIR MOVEMENT
BOTTOM
: 5-1/8" (130mm)
FOR LEGS
*