MN-35949 • Rev 04 • 06/16 • Combitherm® CT PROformance™ Series • Technical Service Manual • 39
Cleaning and Maintenance
The gas Combitherm must use a connector that
complies with The Standard for Connectors for
Movable Gas Appliances, ANSI Z21.69 CSA 6.16 and
addenda Z21.69a-1989. A quick disconnect device must
be installed to comply with The Standard for Quick
Disconnect Devices for Use with Gas Fuel, ANSI Z21
CSA 6.9. and European Standard EN203.
Adequate means must be provided to limit the
movement of this appliance. Limitation of movement
must be made without depending on the connector,
the quick disconnect device, nor the associated piping
designed to limit appliance movement. If it becomes
necessary to disconnect the restraint, it must be
reconnected immediately following the return of the
appliance to its original position.
1. Install a manual gas shut-off valve along with an
approved disconnect device.
2. Install an A.G.A. certifi ed, heavy-duty connector that
complies with ANSI Z 21.69 or
CAN 1-6.10m88 along with a quick-disconnect device
in compliance with ANSI Z21.41 or
CAN 1-6.9m70. Connectors must be installed with
a cable restraint to prevent excessive tension from
being placed on the connector.
WARNING
ELECTRIC SHOCK HAZARD.
To prevent SERIOUS INJURY or DEATH,
your appliance must be secured to building
structure to prevent unintended movement.
Any appliance that is not furnished with a
power supply cord but includes a set of casters must
be installed with a tether. Adequate means must be
provided to limit the movement of this appliance
without depending on or transmitting stress to the
electrical conduit. The following requirements apply:
1. Casters must be a maximum height of 6" (152mm).
2. Two of the casters must be the locking type.
3. Such mobile appliances or appliances on
mobile stands must be installed with the use
of a fl exible connector secured to the
building structure.
A mounting connector for a restraining device is located
on the lower back fl ange of the appliance chassis or on
an oven stand, approximately
18" (457mm) from the fl oor. A fl exible connector is not
supplied by nor is it available from the factory.
This section is provided for the assistance
of qualified and trained service
technicians only and is not intended
for use by untrained or unauthorized
service personnel. Failure to observe this
precaution may void the warranty.
FIRE HAZARD
To prevent SERIOUS INJURY or DEATH,
your appliance must be secured to building
structure to prevent unintended movement.
For Electric Models:
For Gas Models:
Содержание COMBITHERM CT PROFORMANCE 10-10E