Alto-Shaam Combitherm 7.14ESi Скачать руководство пользователя страница 2

# 4 3 6   -   0 5 / 0 7

D U E T O O N G O I N G P R O D U C T I M P R O V E M E N T

,  

S P E C I F I C AT I O N S A R E S U B J E C T T O C H A N G E W I T H O U T N O T I C E

.

WEBSITE

:  www.alto-shaam.com

E L E C T R I C   C O M B I N AT I O N   OV E N / S T E A M E R  

7

14

ESi

C A PA C I T Y

FULL-SIZE PANS: 20" x 12" x 2-1/2"

Fourteen (14)

Thirteen (13)

GN 1/1: 530 x 325 x 65mm

Fourteen (14)

Thirteen (13)

GN 2/1: 650 x 530 x 65mm

Seven (7)

Six (6)

FULL-SIZE SHEET PANS:*

18" x 26" x 1"

Seven (7)

Six (6)

ON WIRE SHELVES ONLY

168 lb (76 kg) 

MAXIMUM

VOLUME MAXIMUM

:  105 

QUARTS

(133

LITERS

)

C L E A R A N C E   R E Q U I R E M E N T S

LEFT

: 6" (152mm)

PLUS SERVICE ACCESS

:  

18" (457mm)

RECOMMENDED

20" (508mm)

F R O M H E AT P R O D U C I N G E Q U I P M E N T

RIGHT

: 4" (102mm)

BACK

: 4" (102mm)

COUNTER

-

TOP INSTALLATIONS MUST MAINTAIN

4" (102mm) 

MINIMUM CLEARANCE FROM THE COUNTER SURFACE

.

W E I G H T

NET

405 lb 

EST

.

(184 kg) 

EST

.

SHIP

542 lb 

EST

.

(246 kg) 

EST

.

CRATE

42" 

X

50" 

X

46" 

EST

.

DIMENSIONS

:

(1067 x 1270 x 1168mm)

E L E C T R I C A L

7 • 1 4

E S

i

7 • 1 4

E S

i / s k

VOLTAGE

PHASE

CYCLE

/

HZ

AWG

AMPS

kW

AMPS

kW

at 208

1*

50/60

2 Wire plus ground

63.5

13.8

65.5

14.3

at 240

AWG 3

76.5

18.3

78.5

18.8

at 208

3

50/60

3 Wire plus ground

38.5/ph

13.8

40.5/ph

14.3

at 240

AWG 6

44.0/ph

18.3

46.0/ph

18.8

at 380

3

50/60

4 Wire plus ground

21.5/ph

14.2

23.5/ph

14.7

at 415

AWG 10

25.5/ph

18.3

27.5/ph

18.8

at 440

3*

50/60

3 Wire plus ground

24.0/ph

15.4

26.0/ph

15.6

at 480

AWG 8

26.0/ph

18.3

28.0/ph

18.8

ELECTRICAL SERVICE CHARGE APPLIES

WAT E R   R E Q U I R E M E N T S

TWO (2) COLD WATER INLETS - DRINKING QUALITY

ONE

(1)

TREATED WATER INLET

:

3/4" NPT

ONE

(1)

UNTREATED WATER INLET

:

3/4" NPT

LINE PRESSURE

:

30 to 90 psi
2.8 to 6.2 bar

REFER TO PUBLISHED SPECIFIC WATER REQUIREMENTS

WATER DRAIN:

1-1/4" NPT 

WITH AIR GAP

I N S TA L L AT I O N   R E Q U I R E M E N T S

Oven must be installed level.

Hood installation is required.

Water supply shut-off valve and back-flow preventer.

2

0

8

-2

4

0

2

0

8

-2

4

0

3

8

0

-4

1

5

4

4

0

-4

8

0

®

TOP VIEW

FRONT VIEW

SIDE VIEW

Helvetica 
Light Condensed 
8 pt

D I M E N S I O N S :

H x W x D

EXTERIOR

:

34-1/4" x 43-7/8" x 42-13/16"  (869mm x 1114mm x 1087mm)

EXTERIOR

 

WITH

 

RETRACTABLE

 

DOOR

:

34-1/4" x 47-7/8" x 42-13/16"  (869mm x 1216mm x 1087mm)

INTERIOR

:

20-5/16" x 23-1/2" x 28-7/16"  (515mm x 596mm x 722mm)

TOP

: 20" (508mm)

FOR AIR MOVEMENT

BOTTOM

: 5-1/8" (130mm) 

FOR LEGS

*

ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY