![Alto-Shaam Combitherm 10-10ES S-Control Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/alto-shaam/combitherm-10-10es-s-control/combitherm-10-10es-s-control_specifications_2912565002.webp)
#430 - 12/07
D U E TO O N G O I N G P R O D U C T I M P R O V E M E N T
,
S P E C I F I C AT I O N S A R E S U B J E C T TO C H A N G E W I T H O U T N O T I C E
.
www.alto-shaam.com
ELECTRIC COMBINATION OVEN/STEAMER
10
10
ES
C A PA C I T Y
FULL-SIZE PANS:
20" x 12" x 2-1/2"
Ten (10)
GN 1/1:
530 x 325 x 65mm
Ten (10)
HALF-SIZE SHEET PANS:*
18" x 13" x 1"
Ten (10)
ON WIRE SHELVES ONLY
120 lb (54 kg)
MAXIMUM
VOLUME MAXIMUM
: 75
QUARTS
(95
LITERS
)
C L E A R A N C E R E Q U I R E M E N T S
LEFT
: 6" (152mm)
PLUS SERVICE ACCESS
:
18" (457mm)
RECOMMENDED
20" (508mm)
F R O M H E AT P R O D U C I N G E Q U I P M E N T
RIGHT
: 4" (102mm)
BACK
: 4" (102mm)
COUNTER
-
TOP INSTALLATIONS MUST MAINTAIN
4" (102mm)
MINIMUM CLEARANCE FROM THE COUNTER SURFACE
.
W E I G H T
NET
385 lb
EST
.
(175 kg)
EST
.
SHIP
495 lb
EST
.
(225 kg)
EST
.
CRATE
49"
X
47"
X
37"
EST
.
DIMENSIONS
:
(1245 x 1194 x 940mm)
E L E C T R I C A L
VOLTAGE
PHASE
CYCLE
/
HZ
AWG
AMPS
kW
at 208
1*
50/60
2 Wire plus ground
67.0
13.9
at 240
AWG 3
77.0
18.4
at 208
3
50/60
3 Wire plus ground
38.5/ph
13.8
at 240
AWG 6
44.0/ph
18.3
at 380
3
50/60
4 Wire plus ground
21.5/ph
14.2
at 415
AWG 10
25.6/ph
18.4
at 440
3*
50/60
3 Wire plus ground
20.0/ph
15.4
at 480
AWG 8
22.0/ph
18.4
*
ELECTRICAL SERVICE CHARGE APPLIES
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE
(1)
TREATED WATER INLET
:
3/4" NPT
ONE
(1)
UNTREATED WATER INLET
:
3/4" NPT
LINE PRESSURE
:
30 to 90 psi
2.8 to 6.2 bar
REFER TO PUBLISHED SPECIFIC WATER REQUIREMENTS
WATER DRAIN:
1-1/2"
FERNCO CONNECTION WITH AIR GAP
I N S TA L L AT I O N R E Q U I R E M E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow preventer.
20
8-
24
0
20
8-
24
0
38
0-
41
5
44
0-
48
0
®
33-1/16" (840mm)
4-15/16"
(125mm)
4
1
-1
/2
"
(1
0
5
3
m
m
)
3
3
-1
5
/1
6
"
(8
6
1
m
m
)
7
-9
/1
6
"
(1
9
2
m
m
)
6
0
-9
/1
6
"
(1
5
3
8
m
m
)
Water Drain
(Back Side)
30" (761mm)
4-3/4" (120mm)
3-3/16" (80mm)
1
1
-7
/1
6
"
(2
9
0
m
m
)
1
4
-3
/1
6
"
(3
6
0
m
m
)
1
5
-7
/8
"
(4
0
3
m
m
)
2" (50mm)
46-7/8" (1190mm)
43-7/8" (1114mm)
31-3/8" (796mm)
34-1/16" (865mm)
17-15/16"
(456mm)
7-9/16"
(191mm)
Water Drain
6
-1
/4
"
(1
5
8
m
m
)
41-15/16" (1064mm)
S
te
a
m
V
e
n
t
(T
o
p
)
Decalcification
Port
Electrical Connection (Bottom)
Treated Water
Intake (Bottom)
Untreated Water
Intake (Bottom)
D I M E N S I O N S :
H x W x D
EXTERIOR
:
41-1/2" x 43-7/8" x 34-1/16" (1053mm x 1114mm x 865mm)
EXTERIOR
WITH
RETRACTABLE
DOOR
:
41-1/2" x 47-7/8" x 34-1/16" (1053mm x 1216mm x 865mm)
INTERIOR
:
27" x 23-1/2" x 21-1/16" (685mm x 597mm x 535mm)
TOP
: 20" (508mm)
FOR AIR MOVEMENT
BOTTOM
: 5-1/8" (130mm)
FOR LEGS
*
ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY