background image

1 2 • 2 0 M W / 2 0 • 2 0 M W O p e r a t i o n & C a r e M a n u a l • 1

D E L I V E R Y

This Alto-Shaam appliance has been

thoroughly tested and inspected to ensure only the
highest quality unit is provided. Upon receipt,
check for any possible shipping damage and report
it at once to the delivering carrier.

See

Transportation Damage and Claims section
located in this manual.

This appliance, complete with unattached

items and accessories, may have been delivered in
one or more packages. Check to ensure that all
standard items and options have been received
with each model as ordered.

Save all the information and instructions

packed with the appliance. Complete and return
the warranty card to the factory as soon as
possible to ensure prompt service in the event of a
warranty parts and labor claim.

This manual must be read and understood by

all people using or installing the equipment
model. Contact the Alto-Shaam service
department if you have any questions concerning
installation, operation, or maintenance.

NOTE:

All claims for warranty must include the
full model number and serial number of
the unit.

U N P A C K I N G

1. Carefully remove the

appliance from the
carton or crate.

NOTE:

Do not discard the
carton and other
packaging material
until you have
inspected the unit
for hidden damage
and tested it for
proper operation.

2. Read all instructions in this manual carefully

before initiating the installation of this appliance.

DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the
appliance and is to be provided to the owner or
manager of the business or to the person
responsible for training operators.

Additional

manuals are available from the Alto-Shaam
service department.

3. Remove all protective plastic film, packaging

materials, and accessories from the appliance
before connecting electrical power. Store any
accessories in a convenient place for future use.

®

®

Содержание CombiMate 12-20MW

Страница 1: ...ONE 262 251 3800 800 558 8744 USA CANADA FAX 262 251 7067 800 329 8744 U S A ONLY www alto shaam com 20 20MW MN 28599 06 10 P R I N T E D I N U S A H o l d i n g C a b i n e t s E l e c t r i c Models 12 20W 12 20MW 20 20W 20 20MW INSTALLATION OPERATION MAINTENANCE 12 20MW 20 20W ...

Страница 2: ...Cleaning Materials 10 Equipment Care 11 Sanitation Sanitation Food Safety 12 Internal Food Product Temperatures 12 Service Electronic Control Accuracy 13 Trouble Shooting Guide 14 Trouble Shooting Error Codes 14 Trouble Shooting Internal Electronic Components 15 Service Parts List 12 20MW 12 20W 16 Cable Heating Kit 12 20MW 12 20W 16 Service View 12 20MW 12 20W 17 Service Parts List 20 20MW 20 20W...

Страница 3: ...ng or installing the equipment model Contact the Alto Shaam service department if you have any questions concerning installation operation or maintenance NOTE All claims for warranty must include the full model number and serial number of the unit U N PA C K I N G 1 Carefully remove the appliance from the carton or crate NOTE Do not discard the carton and other packaging material until you have in...

Страница 4: ...sed to indicate the presence of a hazard that can or will cause minor personal injury property damage or a potential unsafe practice if the warning included with this symbol is ignored C A U T I O N Used to indicate the presence of a hazard that can or will cause minor or moderate personal injury or property damage if the warning included with this symbol is ignored D A N G E R Used to indicate th...

Страница 5: ... Sanitation Foundation floor models must be sealed at bottom by NSF approved sealant or equipped with casters or 6 152mm legs to provide minimum unobstructed space beneath the unit Warranty will become null and void if these directions are not followed CLEARANCE REQUIREMENTS 3 inches 76mm at the back 2 inches 51mm at the top 1 inch 25mm at both sides WEIGHT 12 20MW with cart 12 20W with cart NET 4...

Страница 6: ...250V Plug D A N G E R To avoid electrical shock this appliance MUST be adequately grounded in accordance with local electrical codes or in the absence of local codes with the current edition of the National Electrical Code ANSI NFPA No 70 In Canada all electrical connections are to be made in accordance with CSA C22 1 Canadian Electrical Code Part 1 or local codes D A N G E R ELECTRICAL CONNECTION...

Страница 7: ...oll in Cart DESCRIPTION PART NO Preheat Sealing Strip 5007925 Model 12 20 Roll in Pan Cart electric oven UN 27968 Model 10 20esG Roll in Pan Cart gas oven UN 27964 Model 12 20 Roll in Plate Cart electric UN 27969 2 3 4 between plates Model 12 20 Roll in Plate Cart electric UN 28456 3 3 4 between plates Model 10 20esG Roll in Plate Cart gas UN 27965 Compatible with Combitherm Model 12 20 Oven and Q...

Страница 8: ...e this holding cabinet without its appropriate Roll in Cart DESCRIPTION PART NO Preheat Sealing Strip 5007925 Model 20 20 Roll in Pan Cart UN 27970 Model 20 20 Roll in Plate Cart 2 11 16 69mm spacing UN 27971 3 1 2 89mm spacing UN 28311 Compatible with Combitherm Model 20 20 Oven and QC 100 Quickchiller Stainless Steel Wire Shelves SH 22473 to accommodate full size sheet pans Options Accessories M...

Страница 9: ...at companion holding cabinet preserves the quality and extends the longest possible holding life The Roll In Cart for the 12 20 and 20 20 are completely interchangeable between the Combitherm Oven and the Halo Heat Companion Holding Cabinet along with compatible Alto Shaam Quickchillers The Combitherm Combination Oven Steamer along with the Halo Heat companion holding cabinet and Alto Shaam Quickc...

Страница 10: ...the display press and hold the ON OFF key and the Down Arrow key at the same time The lock LED will extinguish The panel keys will resume normal function CONTROL OPERATION 1 PREHEAT AT 200 F 93 C FOR 30 MINUTES Press the ON key and set the temperature to 200 F 93 by using the UP DOWN arrow keys Allow a minimum of 30 minutes preheating time before loading the holding cabinet with food Closing the v...

Страница 11: ... initial heat to be released from the product This unit is equipped with a thermostat control between 60 and 205 F 16 and 96 C If the unit is equipped with vents close the vents for moist holding and open the vents for crisp holding Use a metal stemmed thermometer to measure the internal temperature of the product being held Adjust the thermostat setting to achieve the best overall setting based o...

Страница 12: ...ter as quickly as possible after rinsing CLEANING AGENTS Use non abrasive cleaning products designed for use on stainless steel surfaces Cleaning agents must be chloride free compounds and must not contain quaternary salts Never use hydrochloric acid muriatic acid on stainless steel surfaces Always use the proper cleaning agent at the manufacturer s recommended strength Contact your local cleaning...

Страница 13: ...interior is completely dry Replace shelves 9 Interior can be wiped with a sanitizing solution after cleaning and rinsing This solution must be approved for use on stainless steel food contact surfaces 10 To help maintain the protective film coating on polished stainless steel clean the exterior of the cabinet with a cleaner recommended for stainless steel surfaces Spray the cleaning agent on a cle...

Страница 14: ...ost accurate method of measuring safe temperatures of both hot and cold foods is by internal product temperature A quality thermometer is an effective tool for this purpose and should be routinely used on all products that require holding at a specific temperature A comprehensive sanitation program should focus on the training of staff in basic sanitation procedures This includes personal hygiene ...

Страница 15: ... indicator DO NOT OPEN THE CABINET DOOR S DURING THE TEMPERATURE STABILIZATION PERIOD If the reading on the thermal indicator does not match the digital display there may be a problem with the air sensor See troubleshooting guide in this manual or call the factory service department for advice SPECIAL FEATURES HEAT RECOVERY The patented SureTemp heat recovery system in this unit will immediately c...

Страница 16: ...it has been below its set temperature for 90 minutes Check the following Oven door may be open or door gasket may need replacement Verify that the oven has been preheated does not contain frozen products and is not overloaded Air sensor probe or relay may be defective there may be a bad wire connection an open heating cable or the high limit switch may be tripped Contact service if problem persist...

Страница 17: ...D To test probe sensor Test food probe by placing in ice water bath and using an ohmmeter set on the ohm scale The reading should be 100 ohms resistance TROUBLE SHOOTING INTERNAL ELECTRICAL COMPONENTS This section is provided for the assistance of qualified technicians only and is not intended for use by untrained or unauthorized service personnel If your Alto Shaam unit is not operating properly ...

Страница 18: ... SCREW SC 2239 2 14 LH TROLLEY TRACK ASSB 5004974 1 42 5 16 18 x 2 HEX HEAD SC 22423 6 15 RH CASING BACK SPOT 5007683 1 43 6 32 x 1 1 4 ROUND HD SC 2365 2 LH CASING BACK SPOT 5008418 1 44 8 32 x 1 4 PHIL SCREW SC 2459 12 16 LH CORNER POST SPOT 5007685 1 45 1 4 20 x 3 4 FLANGED HD SC 25286 6 RH CORNER POST SPOT 5008415 46 HINGE HG 26015 3 17 SIDE PANEL SPOT ASSB 5007687 2 47 SENSOR 1 3 4 L SN 33541...

Страница 19: ...0 39 7 8 4 44 3 17 11 36 16 6 5 41 20 18 12 13 49 42 33 38 46 19 22 47 1 30 45 14 35 23 2 29 28 25 46 26 40 17 3 10 44 32 48 31 54 55 55 57 56 52 53 1 2 2 0 M W A N D 1 2 2 0 W S E R V I C E Part numbers and drawings are subject to change without notice ...

Страница 20: ...2 PHIL FLAT HEAD SCREW SC 2239 2 16 RH CORNER POST WELD ASSB 5004807 1 45 5 16 18 X 2 HEX HEAD SC 22423 6 LH CORNER POST WELD ASSB 5005214 1 46 6 32 X 1 1 4 ROUND HD SC 2365 2 17 RH CASING BACK SPOT 5004813 1 47 8 32 x 1 4 PHIL SCREW SC 2459 12 LH CASING BACK SPOT 5005217 1 48 1 4 20 X 3 4 FLANGED HD SC 25286 6 18 RH TROLLEY TRACK ASSB 5004973 1 49 SENSOR 1 3 4 L QC S 1200 SR SN 33541 1 19 LH TROL...

Страница 21: ... 2 0 2 0 M W A N D 2 0 2 0 W S E R V I C E 26 15 11 12 38 6 16 11 17 25 5 47 38 8 3 4 14 45 52 22 37 32 18 35 38 7 13 27 41 30 29 39 23 10 40 48 36 19 34 33 2 42 50 55 55 56 54 57 Part numbers and drawings are subject to change without notice ...

Страница 22: ...5007289 1 3 Trolley Handle Mount 5006099 1 4 Drip Tray Collector 1007306 1 20 20MW PAN CART DESCRIPTION PART NO QTY 1 Trolley Frame Assembly 5006095 1 2 Trolley Rack Assembly 5006007 1 3 Trolley Handle Assembly 5006099 1 4 Drip Pan 1007306 1 5 Teflon Block BK 22100 1 6 Block Screw SC 2072 2 햲 햲 햳 햳 햴 햴 햵 햵 햶 햷 Part numbers and drawings are subject to change without notice ...

Страница 23: ...12 20MW 20 20MW Operation Care Manual 21 ...

Страница 24: ...12 20MW 20 20MW Operation Care Manual 22 ...

Страница 25: ...warranty claim must be asserted during the applicable warranty period This warranty is not transferable THIS WARRANTY DOES NOT APPLY TO 1 Calibration 2 Replacement of light bulbs and or the replacement of display case glass due to damage of any kind 3 Equipment damage caused by accident shipping improper installation or alteration 4 Equipment used under conditions of abuse misuse carelessness or a...

Отзывы: