No. 4878 for all except 4000W cabinets
INCLUDES
:
CB-3045 Cable Heating Element . .85 feet (2591cm)
CR-3226 Ring Connector . . . . . . . . . . . . . . . . . . . .4
IN-3488 Insulation Corner . . . . . . .1 foot (30,5cm)
BU-3105 Shoulder Bushing . . . . . . . . . . . . . . . . . .4
BU-3106 Cup Bushing . . . . . . . . . . . . . . . . . . . . . .4
ST-2439
Stud . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
NU-2215 Hex Nut . . . . . . . . . . . . . . . . . . . . . . . . . .8
SL-3063 Insulating Sleeve . . . . . . . . . . . . . . . . . . .4
TA-3540 Electrical Tape . . . . . . . . . . . . . . . . .1 roll
No. 4881 for 4000W cabinets
INCLUDES
:
CB-3045 Cable Heating Element .210 feet (6401cm)
CR-3226 Ring Connector . . . . . . . . . . . . . . . . . . . .12
IN-3488 Insulation Corner . . . . . . . .1 foot (30,5cm)
BU-3105 Shoulder Bushing . . . . . . . . . . . . . . . . . .12
BU-3106 Cup Bushing . . . . . . . . . . . . . . . . . . . . . .12
ST-2439 Stud . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
NU-2215 Hex Nut . . . . . . . . . . . . . . . . . . . . . . . . .24
SL-3063 Insulating Sleeve . . . . . . . . . . . . . . . . . .12
TA-3540 Electrical Tape . . . . . . . . . . . . . . . . . .1 roll
CABLE HEATING SERVICE KIT
(
O N E K I T P E R C A BI N E T C O M PA RT M E N T
)
S E R V I C E
T R O U B L E S H O O T I N G - M A N U A L C O N T R O L
Error
Code
Description/Results
Possible Cause
E-10
Air Sensor Shorted
Inoperative Unit
Defective sensor or damaged sensor connection.
E-11
Air Sensor Open
Inoperative Unit
Defective sensor or poor sensor connection.
E-30
Under temperature
Cavity has been under its set
temperature for 90 minutes.
Oven will not reach set temperature
Door gasket damaged or door left open.
Pre-heat skipped before loading the oven.
Loading the oven with frozen product.
Defective sensor or poor sensor connection.
Defective solid state relay.
Defective heater element.
E-31
Over temperature
Unit has exceeded its maximum
allowable set temperature by
25 degrees.
Unit will shut down
Defective sensor or poor sensor connection.
Defective solid state relay.
Shorted heater element.
E-70
Configuration error
Inoperative Unit
Contact Alto-Shaam Service Department.
E-82
or
E-83
EEPROM - Calibration data error
Inoperative Unit
Contact Alto-Shaam Service Department.
E-90
Button shorted
Inoperative Control
Stuck button on control panel. Check buttons.
If control is still inoperative, contact Alto-Shaam Service Department.
E-91
Input failure
Contact Alto-Shaam Service Department.
Содержание 1200-UP Series
Страница 30: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 29 ...
Страница 31: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 30 ...
Страница 32: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 31 ...
Страница 33: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 32 ...
Страница 34: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 33 ...
Страница 35: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 34 ...
Страница 36: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 35 ...
Страница 37: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 36 ...
Страница 38: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 37 ...
Страница 39: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 38 ...