Page 15
Hydra Series AIP-200 LED Luminaires
Installation & Users Manual
Loss of DMX action
Step 1 - Navigate to No DMX
No DMX in the menu.
Step 2 - Press Enter.
3 options are available:
•
Off (turn the luminaire off - no light output)
•
Last Hold (hold the last look before signal was lost). Note, if DMX is lost and the luminaire is at zero inten-
sity (no output), it will remain (hold) at zero intensity.
•
Power Up Preset - (turns on the Power up Preset)
Power Limit - Maximum Power Limit
Step 1 - Navigate to Power Limit
Power Limit in the menu.
Step 2 - Press Enter.
A setting from 1-100% of maximum can be set. The AIP-200 will not utilize more than the upper threshold of
power set here.
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
*
20W
40W
60W
80W
100W
120W
140W
160W
180W
200W
Each dimming curve has a different low-end and high-end set point. If luminaries are set to different dimming
curves the luminaires will react very differently. To ensure consistent dimming between luminaires, please set
all AIP-200 Par Luminaires to the same dimming curve.
Power Up Action - Start-Up Sequence
Step 1 - Navigate to Power Up
Power Up in the menu.
Step 2 - Press Enter.
3 options are available:
Preset:
•
Last Status - The luminaire will recall its last state
•
Preset (1-20) - The luminaire will replay one of the programmable presets, please refer to the
Contro
section on page 31.
•
Color Filter - Selects one of 43 colors pre-programmed in the luminaire, please refer to the
Control
section on page 31.
Fade Time:
•
0 - 5 minutes
* - Default