background image

ACCESSORIES

3

equipment in a residential area is likely to
cause harmful interference in which case
the user will be required to correct the
interference at his own expense.

 

Any changes or modifications to the unit not
expressly approved by ALTINEX, Inc. could
void the user’s authority to operate the
equipment.

ABOUT YOUR TNP500/502

2

The 

TNP500

 designed for installation into a table in a

presentation or boardroom, the Tilt `N Plug™
Configurable Tabletop Interconnect Box provides
access to multi-media input connections when
needed, and hides them when not needed. This unit
can be configured with a wide variety of data or A/V
connectors before shipment from ALTINEX.
Using a tilting angular construction with pneumatic lift
assist and a mechanical latching mechanism, the

TNP500

 can either "tilt up" into a raised position to

provide access to input plates, or it can be lowered
flush into the table when not in use. The unit is
opened and closed by pressing down on the top
panel.

Note that, while the 

TNP500

 is similar in many ways

to its predecessor (TNP100), it actually performs the
lifting function internally, and does not require the user
to lift the faceplate up. Only light pressure is required
to unlatch the top to open it, and slightly more
pressure to push the lid down and close the unit.

The 

TNP500

 provides six Sectional Plate slots on the

exposed faceplate, servicing one side of a table.
Signals are passed through the unit to the underside
of the table. A variety of sectional plate connector
configurations are available to populate the slots - see
Sectional Plate Accessories for a list of available
options. All Sectional Plates must be ordered
separately.

The 

TNP502

 is a "package" of parts that covers the

basic needs of many Tilt ‘N Plug users. When this
item is ordered, it ships as a completely assembled
product made up of: one TNP500 and a  SP3500SC
Sectional Plate, with input labels already engraved
The SP3500SC includes the following connectors:
two standard U.S. power receptacles, computer video
(15-pin HD), COM Port/RS-232 (9-pin D), composite

video (RCA), S-Video (4-pin mini-DIN), audio (2-
RCAs), computer audio (3.5 mm), modem (RJ11),
and network (RJ45) input connectors. All connectors
have 6 foot cables attached that feed through to the
bottom of the unit. The connectors and their labels
may be customized for a fee.

TECHNICAL SPECIFICATIONS

3

FEATURES/

DESCRIPTION

TNP502

GENERAL
Front Panel
Standard
Configuration
Connectors

Faceplate

Available

location

Power

2 outlet per plate

Up to 3 plates

Computer Video

1 15-pin HD-F

Up to 6 plates

Composite Video

1 Yellow RCA-F

Up to 6 plates

Audio, left, right

1 Black, 1 Red

RCA-F

Up to 6 plates

Audio

1 3.5 mm stereo

female plug

Up to 6 plates

Telephone

1  RJ-11 F (6-

position)

Up to 6 plates

Network

1  RJ-45-F (8-

position)

Up to 6 plates

Control

1 DB-9 F

Up to 6 plates

   Table 1. 

TNP502 

General

MECHANICAL

TNP500/502

Width (inches)

6.03in (153mm)

Height (closed)

4.79in (122mm)

Height (opened)

8.05in (205mm)

Depth (inches)

7.56in (192mm)

Finish

Flat Black

T

°

 Operating

10

°

C-45

°

C

T

°

 Maximum

60

°

C

Humidity

90

%

 non-condensing

   Table 2. 

TNP500/502

 Mechanical

ELECTRICAL

TNP502

Power

Power Rating (pass through
connector)

90-140 VAC, 5Amps

Max

   Table 3. 

TNP502 

Electrical

Содержание TNP500

Страница 1: ...ACCESSORIES MANUAL PART NUMBER 400 0091 005 TNP500 502 Universal Tilt N Plug Interconnect Box USER S GUIDE...

Страница 2: ...and simple to operate We are committed to providing our customers with signal management solutions to the most demanding audio visual installations at very competitive pricing We appreciate your selec...

Страница 3: ...n on the top of the unit To turn off the main power disconnect the power cord which powers the power socket on the TNP500 502 pop up panel The power outlet socket should be installed as near to the eq...

Страница 4: ...e connector configurations are available to populate the slots see Sectional Plate Accessories for a list of available options All Sectional Plates must be ordered separately The TNP502 is a package o...

Страница 5: ...ACCESSORIES 4 TNP500 502 DIMENSIONS 4 Detailed dimensions tabletop cutout templates and CAD drawings are available on the ALTINEX website at www altinex com...

Страница 6: ...Many different plates can be installed on TNP500 In addition to standard plates any custom plates can be made using blank plates available Additional description and part numbering is available on Al...

Страница 7: ...ACCESSORIES 6 Final Installation view of TNP 502 Sample configiration with modules installed...

Страница 8: ...ACCESSORIES 7 DESCRIPTION 5 4 Final Installation view of TNP 502 APPLICATION DIAGRAM 6...

Страница 9: ...tom of the table using the 6 32 screw There are two support brackets one for each side of the unit Step 4 Secure the cables by using the provided cable clamp Pass the power cord from the bottom of the...

Страница 10: ...compatible with RS 232 serial communication 3 What happens if the spring breaks The unit will not stay open 4 What do I do if the TNP500 502 won t stay open Replace the gas spring Call ALTINEX for se...

Страница 11: ...ly tested and no problems were detected however we would like to offer the following suggestions If there is no power check the integrity of the power cord Make sure that no cable or power cord is dam...

Отзывы: