background image

TNP327 

User’s Guide 

400-0704-004

 

 

 

 

 

 

9

7. Operation 

7.1 Opening and Closing the Tilt 'N Plug 

The Tilt 'N Plug will open easily when the top is pressed down 
and then released. 

When the Tilt 'N Plug is not in use, simply press the top down 
until it is level with the surface of the table and then release.  The 
unit will remain hidden until needed again.  

7.2 Power/Signal Connections 

Connect external devices to the appropriate connector on the 
Tilt 'N Plug. Remember, the devices plugged into the AC power 
connectors should not draw more than 12A total. 

 

 

8. Troubleshooting Guide 

The Tilt 'N Plug supplied was carefully tested and no problems were detected. However, we would like to offer the following 
suggestions: 

TNP 

Symptom 

Resolution 

Signal quality is poor.  

1.  Please make sure that the highest quality video and network cables are used. 
2.  The TNP is a passive unit and does not alter signals in any way. If there is suspected problem 

with the signal quality, check the quality of the cables coming into and the TNP and connecting 
to the output of the TNP. If they are of low quality or improperly assembled, this will affect the 
overall quality of the signal. 

Damaged power cord 

1.  Make sure that no cable or power cord is damaged or pinched.  
2.  If there has been damage, do not use the Tilt 'N Plug. Please call the Altinex Customer Service 

Department at (714) 990-2300 to have the unit repaired. 

Unit raises too slowly 

1. If the unit does not rise into position correctly, check the service loops for the signal and power 

cords on the bottom of the unit. If the service loop is too small the cables will counteract the 
spring trying to raise the unit into position. 

Unit tilts up too fast 

1. If the unit rises into position too fast, check the service loops for the signal and power cords on 

the bottom of the unit. If the service loop is too large and the cables are putting upward pressure 
on the unit, the unit will tilt up too fast. 

Unit does not close all 
the way 

1. If the unit does not close flush with the bezel, check the service loops for the signal and power 

cords on the bottom of the unit. If the service loop is putting upward pressure in the unit, the unit 
will not be able to seat all the way down. 

 