background image

TNP51

TNP51

TNP51

TNP510/512 

0/512 

0/512 

0/512 Tilt ‘N Plug

Tilt ‘N Plug

Tilt ‘N Plug

Tilt ‘N Plug

®

 

    

User’s Guide

    

400-0521-001 

 

 
 
 
 
 
 

Welcome! 

We greatly appreciate your purchase of the Tilt ‘N Plug. We are sure you will 
find it reliable and simple to use. Superior performance for the right price, 
backed by solid technical and customer support is what ALTINEX has to 
offer. 

We are committed to providing our customers with 
Signal Management Solutions

®

 to the most demanding audiovisual 

installations at very competitive pricing and we welcome you to join the 
ranks of our many satisfied customers throughout the world. 

1. Precautions and Safety Warnings 

Please read this manual carefully before using your TNP510/TNP512 
Interconnect. Keep this manual handy for future reference. These safety 
instructions are to ensure the long life of your TNP510/TNP512 and to 
prevent fire and shock hazards. Please read them carefully and heed all 
warnings. 

1.1 General 

 

Qualified ALTINEX service personnel or their authorized 
representatives must perform all service. 

1.2 Installation Precautions 

 

For best results, place the TNP510/TNP512 Interconnect Box in a dry 
area away from dust. 

 

To prevent fire or shock, do not expose this unit to water or moisture. 
Do not place it in direct sunlight, near heaters or heat-radiating 
appliances, or near any liquid. Exposure to direct sunlight, smoke, or 
steam can harm internal components. 

 

Handle the unit carefully. Dropping or jarring can damage the bezel. 

 

Never place fingers inside the opening on either side of the unit. This 
action could cause injury due to sharp edges inside. 

 

Do not place heavy objects on top of the TNP510/TNP512. Do not use 
excessive force to push down on the top of the unit. 

 

Disconnect the    power cord to turn off the main power. This supplies 
power to the power socket on the pop-up panel. The power outlet 
should be installed near the equipment and should be easily accessible. 

 

We recommend using wall outlets with a Ground Fault Circuit 
Interrupter (GFCI) for maximum protection. 

 

Install all cables according to the instructions found herein. Do not 
force or pull out any cable or power cord attached to the unit. 

1.3 Cleaning 

 

Surfaces should be cleaned with a dry cloth. Never use strong 
detergents or solvents such as alcohol or thinner. Do not use a wet cloth 
or water to clean the unit. 

1.4 FCC Notice 

 

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not cause 
harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation. 

 

This equipment has been tested and found to comply with the limits for 
a Class A digital device, pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instructions found herein, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is 
likely to cause harmful interference in which case the user will be 
required to correct the interference at his expense. 

 

Any changes or modifications to the unit not expressly approved by 
ALTINEX, Inc. could void the user’s authority to operate the 
equipment. 

 

 

2. Installation Procedures 

Step 1. 

Cut an opening into the table’s surface. Refer to the ALTINEX website at 

www.altinex.com

 for table cutout requirements. 

 

Note: The table can be 2.50 in (64 mm) or less in thickness. Always confirm dimensions before cutting to insure that specifications have not changed.  

Step 2. 

Insert the TNP510/TNP512 into the table cutout.  

Step 3. 

Place the support brackets under the table and place them between the support mount grooves on the side of the unit. Attach the brackets to the 
groove at the desired height and secure them to the bottom of the table using the thumb screws provided. See Diagram 5 for details. 

Step 4. 

To lower the unit, push on the top cover until it locks into place. 

If Custom Plates are Installed 

Step 5. 

Secure all cables to the underside of the table using the cable clamps and screws included with the TNP510/TNP512. Pass the power cord from the 
bottom of the housing and attach it to the table separate from the signal cables. 

 

Leave enough slack in the service loop to allow for easy opening and closing, but not too much as to cause excess drooping of the service loop. 

Step 

 

6. 

Connect the appropriate cables with the correct input connectors on the bottom of the unit.  

Step 7. 

Once you have applied power and connected the proper cables on the bottom of the unit you may raise the unit. To raise the unit into position, push 
down on the front of the top cover; the latching mechanism will then release, allowing the pneumatic spring to raise it into position. 

NOTE: 

It may be necessary to adjust the service loop of the cables for optimal performance. 

 

3. Limited Warranty/Return policies 

Please see the ALTINEX website at 

www.altinex.com

 for details on warranty and return policies. 

Содержание Tilt N Plug TNP510

Страница 1: ...cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the...

Страница 2: ...o 15 pin HD F M 1 Network RJ 45 F M 1 Modem RJ 11 F M 1 S Video 4 pin Mini DIN F M 1 Composite Video Yellow RCA F F 1 Control DB 9 F M 1 Audio Stereo 3 5 mm F M 1 Audio Left Channel Red RCA F F 1 Audi...

Страница 3: ...NP510 is empty but provides slots for 6 single slot sectional plates that can be configured with various multimedia and power inputs Many sectional plates are available for the TNP510 and ordered sepa...

Страница 4: ...Tilt N Plug Tilt N Plug Tilt N Plug Tilt N Plug User s Guide 400 0521 001 4 6 Application Diagrams Diagram 1 Typical Setup...

Страница 5: ...Tilt N Plug Tilt N Plug Tilt N Plug Tilt N Plug User s Guide 400 0521 001 5 Diagram 2 Front Dimensions 7 5 191 mm 0 25 6 mm...

Страница 6: ...Tilt N Plug Tilt N Plug Tilt N Plug Tilt N Plug User s Guide 400 0521 001 6 Diagram 3 Side Dimensions INTERFACE 3 3 83 mm 4 2 107 mm 5 9 150 mm OPERATOR...

Страница 7: ...Tilt N Plug Tilt N Plug Tilt N Plug Tilt N Plug User s Guide 400 0521 001 7 Diagram 4 Top Dimensions 6 5 166 mm 7 9 200 mm...

Страница 8: ...Tilt N Plug Tilt N Plug Tilt N Plug Tilt N Plug User s Guide 400 0521 001 8 Diagram 5 Mounting Sample OPERATOR BRACKETS 2 SUPPORT THUMBSCREWS 2 TABLETOP INTERFACE...

Страница 9: ...fferent plates can be installed on the TNP510 using up to 6 slots total In addition to standard plates custom plates can be made using blank plates available For a complete listing and detailed descri...

Страница 10: ...10 TNP512 Remember the devices plugged into the AC power connectors should not draw more than 600W of power 8 Troubleshooting Guide The TNP510 TNP512 supplied was carefully tested and no problems were...

Отзывы: