background image

INTERFACES

2

PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your

VA6834FC

 Interface. Keep this manual handy for

future reference. These safety instructions are to
ensure the long life of your 

VA6834FC 

and to

prevent fire and shock hazard. Please read them
carefully and heed all warnings.

1.1 GENERAL

 Unauthorized personnel shall not open the unit

since there are high-voltage components
inside.

 Qualified Altinex service personnel, or their

authorized representatives must perform all
service.

1.2. SAFETY GUIDELINES FOR THE RACK-

MOUNTING OF THE VA6834FC

 Maximum operating ambient temperature is 35

(degrees C).

 Never restrict the airflow through the devices’

fan or vents.

 When installing equipment into a rack,

distribute the units evenly. Otherwise,
hazardous conditions may be created by an
uneven weight distribution.

 Connect the unit to a properly rated supply

circuit.

 Reliable Earthing (Grounding) of Rack-

Mounted Equipment should be maintained.

1.3 INSTALLATION

 For best results, place the 

VA6834FC

Interface on a flat, level surface in a dry area
away from dust and moisture.

 To prevent fire or shock, do not expose this

unit to rain or moisture. Do not place the

VA6834FC

 Interface in direct sunlight, near

heaters or heat radiating appliances, or near
any liquid. Exposure to direct sunlight, smoke,
or steam can harm internal components.

 Handle the 

VA6834FC

 Interface carefully

because dropping or jarring can damage
internal components.

 Do not place heavy objects on top of the

VA6834FC

. If the 

VA6834FC

 is to be mounted

to a table or wall, use only Altinex made
mounting accessories, such as brackets
(

DA1293FC 

or

 DA1294FC

) and cables for

optimum setup.

 To turn off the main power, be sure to remove

the power cord from the power outlet. The
power outlet socket should be installed as
near to the equipment as possible, and should
be easily accessible.

 Do not pull the power cord or any cable that is

attached to the 

VA6834FC

 Interface.

 If the 

VA6834FC

 Interface is not used for an

extended period, disconnect the power cord
from the power outlet.

1.4 CLEANING

 Unplug the 

VA6834FC

 power cord before

cleaning. Clean surfaces with a dry cloth.
Never use strong detergents or solvents, such
as alcohol or thinner. Do not use a wet cloth or
water to clean the unit.

1.5 FCC / CE NOTICE

 This device complies with Part 15 of the FCC

Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.

 This equipment has been tested and found to

comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and
used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.

Содержание System Analog Interface VA6834FC

Страница 1: ...INTERFACES MANUAL PART NUMBER 400 0039 003 PRODUCT REVISION 1 VA6834FC SYSTEM ANALOG INTERFACE USER S GUIDE...

Страница 2: ...atisfied customers throughout the world This manual covers VA6834FC VGA Pack VA6834FC MAC Pack VA6834FC SUN SGI Pack VA6834FC RGB Pack VA6834FC Combo Pack VA6834FC Super Pack TABLE OF CONTENTS Page PR...

Страница 3: ...C If the VA6834FC is to be mounted to a table or wall use only Altinex made mounting accessories such as brackets DA1293FC or DA1294FC and cables for optimum setup To turn off the main power be sure t...

Страница 4: ...ct size advanced features and very competitive pricing TECHNICAL SPECIFICATIONS 3 FEATURES DESCRIPTION VA6834FC GENERAL Inputs 1 Computer Video Input Connector 15 pin HD Female Outputs Local Monitor O...

Страница 5: ...no need to terminate the unused output The termination switch on the VA6834FC affects only the terminations of the computer video input The output is VGA compatible but can also be used to feed other...

Страница 6: ...INTERFACES 5...

Страница 7: ...INTERFACES 6...

Страница 8: ...nt dial fully to the right the control will click into a locked position In this position the VA6834FC outputs the same sync type as that which is fed into it from the source In this setting the VA683...

Страница 9: ...appropriate Altinex Local Monitor cables It is not necessary to terminate this output with a termination plug if a local monitor is not being used Step 5 Connect one end of a BNC cable to output 1 or...

Страница 10: ...ity When the I D Bit switch is in the ON position the VA6834FC allows the main ID Bit pin 4 on the input connector to be connected to the ground signal This is used primarily when interfacing to lapto...

Страница 11: ...o 5 BNC coaxial cable CB4206MR 6 ft 5 BNC to 5 BNC coaxial cable CB4212MR 12 ft 5 BNC to 5 BNC coaxial cable CB4225MR 25 ft 5 BNC to 5 BNC coaxial cable CB4250MR 50 ft 5 BNC to 5 BNC coaxial cable CB4...

Страница 12: ...izontal position using the monitor or projector s control Then use the horizontal Position Control of the VA6834FC if needed 3 What dip switch do I set to obtain composite SYNC output If the desired o...

Страница 13: ...tion if no Y cable breakout is used on the input 3 Make sure that the cables have the correct pin outs and the connection and quality of the cables are good 4 Make sure that the source and display are...

Страница 14: ...he product that you have ordered and that this product fulfills your need In the unlikely event that an Altinex product needs to be returned please follow the policies below Altinex will accept produc...

Отзывы: