SWITCHERS

12

CB36100MR

100 feet MAC Male to Female

CB36150MR

150 feet MAC Male to Female

POWER CABLES

PC5301US

Power cable for US

PC5302US

Power cable for U.K.

PC5303US

Power cable for Australia

PC5304US

Power cable for Germany

FREQUENTLY ASKED QUESTIONS

9

No

Question

Answer

1

When I press
F1 nothing
happens.
What is a
purpose of
this function?

The F1 function is reserved
for future use. It does not
perform any functions at the
present time.

2

What is the
LED next to
the F1
button used
for?

This LED is also reserved for
future use. It is currently non-
operational.

3

When I
press the
RESET
button, the
switcher
does not
respond.
Why?

You must press and hold the
button for approximately 2
seconds, until you hear a
beeping sound and all of the
LED lights flash. This is
designed to avoid accidental
resetting.

4

Can the

MX2416RM

be rack
mounted?

The 

MX2416RM

 can be rack

mounted by itself or two units
side by side. The width of the
unit is 1/2 rack wide. Altinex
offers rack mount ears for
single unit mounting
(part# 

DA1299RM

) and rack

shelf for two unit mounting
(part# 

DA1298RM

).

5

Can the

MX2416RM

be used to
pass
Composite
Video, S-
Video or
Component
Video?

Yes, simply use the
corresponding channels to
pass the signals (e.g. For
composite video, you may use
the red input channel and the
red output channel, or you can
use the blue input channel and
the blue output channel).
Since the 

MX2416RM

 is a

relay switcher, it can be used
as a contact closure control or
to switch virtually any type of
video signal.

6

Can the

MX2416RM

Switcher be
used
outside of
the United
States

Yes, the 

MX2416RM

 uses a

universal internal power
supply, enabling it to be used
throughout the world. Please
make sure to have the voltage
setting in the correct position
and please make sure to use
the proper adapter cable for
the country where it will be
used. Adapter cables for
several countries are available
through Altinex.

7

How do I
control
several
switchers
with one
RS-232
card in a
control
system?

You can control multiple
switchers with one card at this
time. The unit has ID codes
and can be differentiated by
the control system. Call Altinex
if this requirement is important
for your system.

8

Can I use
contact
closure to
control the
switcher?

A special cable that plugs into
the RS-232 port and converts
contact closure into analog
control is available. This is

RC5204CC

 cable is made by

Altinex on request.

9

Can the

MX2416RM

switcher be
looped with
other

MX2416RM

Switchers?

Yes, in exactly the same way
as described in this manual
when the 

MX2416RM

 is

slaved to another 

MX2416RM

.

TROUBLESHOOTING GUIDE

10

 Please make sure that the input signal formats

are same for input (source) and output (display).

 Please make sure that the input signal amplitude

levels are as follows:

1. RED, GREEN, BLUE is less than 10 V.

Содержание MX2414RM

Страница 1: ...SWITCHERS MANUAL PART NUMBER 400 0020 003 PRODUCT REVISION 0 MX2416RM MX2414RM 6 4 IN 1 OUT VGA MAC SWITCHER USER S GUIDE...

Страница 2: ...satisfied customers throughout the world This manual covers MX2416RM 6 in 1 out VGA MAC Switcher MX2414RM 4 in 1 out VGA MAC Switcher TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RAC...

Страница 3: ...accessories like rack mount shelf DA1298RM or rack mount ears DA1299RM and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet socket...

Страница 4: ...ke the switcher respond as a single unit Using a similar method multiple MX2416RM units can be made to operate in a Master Slave mode with all units responding to a single button selection Although ve...

Страница 5: ...ompatibility Typical Video Bandwidth 400 MHz 3 dB Horizontal 15 200 kHz Vertical 30 190 Hz Cross talk 48dB 10 MHz Coupling DC Power External Power Adapter 90 140V 200 240V Power Consumption 12 watts m...

Страница 6: ...s function key F2 to switch to a no signal condition The LED next to the F2 function key will light to indicate that the switcher is in this mode To resume input select switching simply press the desi...

Страница 7: ...nly 2 wires one to pin 9 and one to ground are required to connect and control all of the switchers The selection of channels can also be accomplished by RS 232 on the master switcher with all slave s...

Страница 8: ...s access to a variety of control capabilities PIN No PIN Designation 1 No connection 2 RS 232 Transmit 3 RS 232 Receive 4 No connection 5 Ground 6 Multiple Switcher Loop Control 7 Analog Switch Voltag...

Страница 9: ...being used by the switcher such as an error string ERR will be returned If the control system being used is not setup to wait for the OK string it is important to include a 100 milliseconds delay bet...

Страница 10: ...232 control MX2416RM 9 pin D Master PIN No MX2416RM 9 pin D Slave PIN No 2 3 5 5 Master Slave Control Port Connection A Master Slave configuration can be achieved also by Analog Switch Voltage using p...

Страница 11: ...he same pin on all switchers MX2416RM LOOP MX2416RM LOOP 6 6 5 5 MX2416RM 9 pin D Loop The loop control pin has an internal 100k resistor to 5volts This limits the number of switchers that can be loop...

Страница 12: ...706MR 6 feet VGA Male to Male CB3715MR 15 feet VGA Male to Male CB3725MR 25 feet VGA Male to Male CB3750MR 50 feet VGA Male to Male CB3775MR 75 feet VGA Male to Male CB37100MR 100 feet VGA Male to Mal...

Страница 13: ...t channel or you can use the blue input channel and the blue output channel Since the MX2416RM is a relay switcher it can be used as a contact closure control or to switch virtually any type of video...

Страница 14: ...harges pre paid within 2 years 90 days for cables from date of shipment to the purchaser The warranty is expressly instead of all other warranties expressed or implied Altinex neither assumes nor auth...

Отзывы: