background image

MULTITASKER

400-0162-003

10

8.  

[?]

This command displays general information 
about a MultiTasker and its installed cards.

Command Format: [?Ui]

Ui

= Unit ID (i = from 0 to 20)

Example:

A MultiTasker with unit ID 1 has a front panel 
with part number MT101-101 and contains an 
MT103-122, MT103-123, and MT108-103. Send 
the command [?U1] and receive the following 
feedback:

[(MT101-101U1)(MT103-122C01) 
(MT103-123C02)(MT108-103C04)]

MT101-101U1

= Panel number/unit ID

MT103-122C01 = MT103-122 is in slot 1
MT103-123C02 = MT103-123 is in slot 2
MT108-103C04 = MT108-103 is in slot 4

9.  

[?C]

This command displays general information 
about a card and its status.

Command Format: [?Cn]

Cn = Card ID (n = # from 1 to max slots)

Example:

The 

MT108-103

in slot 4 has Outputs 1-3 turned 

on and the remaining output is disabled. Send 
the command [?C4] to receive feedback status 
similar to the following. 

[(MT108-103C04)(VR690-0127-009C04) 
(ON1110C04)]

All status feedback is enclosed in brackets, “[ ]“. 
Each data field within the status is enclosed in 
parentheses. The first two characters identify 
the status type. The last three characters are the 
card’s ID.

MT108-103

= Card model number

VR690-0127-009

= Firmware version

ON1110

= Output ON/OFF status

The ON/OFF status line is read from left to right 
as Outputs 1-4. A "1" indicates the output is on 
and a "0" indicates the output is off.

10.  

[STA1]

This command enables automatic feedback 
from the front panel. The command affects any 
card with auto-feedback capability, not just the 

MT108-103

. The default at power on or reset is 

STA0, off. For more details, see the [?Cn] 
command definition.

Command Format: [STA1]

Feedback Prefix Definitions:
MT

Card model number

VR

Firmware version

ON

Output on/off status

Example:

Command =

[OFF1C4]

Feedback =

(ON0111C04)

ON

= Output on/off status

0111

= Out 1 off, 2-4 on

C04

= Card ID/slot number

11.  

[STA0]

This command disables automatic feedback 
from the card and front panel. The command 
affects any card with auto-feedback capability, 
not just the 

MT108-103

card

.

The default at 

power on or reset is STA0, OFF.

Command Format: [STA0]

12.  

[…F] – FEEDBACK

After processing a command, an “OK” or 
“[ERR001]” will be returned as feedback if ‘F’ is 
included at the end of a command string.

Содержание MULTI-TASKER MT108-103

Страница 1: ...MULTITASKER MANUAL PART NUMBER 400 0162 003 1 IN 4 OUT BALANCED STEREO AUDIO DISTRIBUTION AMPLIFIER WITH OUTPUT CONTROL USER S GUIDE MT108 103...

Страница 2: ...S 5 DIAGRAM 1 TYPICAL SETUP 5 DIAGRAM 2 INTERNAL VIEW 6 INSTALLING YOUR MT108 103 7 OPERATION 7 RS 232 CONTROL 7 DESCRIPTION OF COMMANDS 8 COMMAND ORGANIZATION 8 BASIC COMMANDS 8 FEEDBACK CONTROL 9 CA...

Страница 3: ...strong detergents or solvents such as alcohol or thinner Do not use a wet cloth or water to clean the card Do not clean or touch any component or PCB 1 5 FCC NOTICE This device complies with Part 15...

Страница 4: ...ndependently using RS 232 commands sent to the MultiTasker from a control system or from the enclosure s front panel keys TECHNICAL SPECIFICATIONS 3 Specifications are subject to change See www altine...

Страница 5: ...MULTITASKER 400 0162 003 4 PRODUCT DESCRIPTION 4 BOTTOM RETAINER SCREW 4 AUDIO OUTPUTS AUDIO INPUT PRESENT LED POWER SIGNAL TOP RETAINER SCREW...

Страница 6: ...MULTITASKER 400 0162 003 5 APPLICATION DIAGRAMS 5 DIAGRAM 1 TYPICAL SETUP MT108 102 MT113 101...

Страница 7: ...MULTITASKER 400 0162 003 6 DIAGRAM 2 INTERNAL VIEW INPUT BALANCED LEFT RIGHT 5 pin TERM BLK ON OFF CONTROL SIGNAL DETECT POWER OUT 3 OUT 4 OUT 1 OUT 2 OUTPUTS BALANCED LEFT RIGHT 5 pin TERM BLK...

Страница 8: ...ough standard RS 232 communication Control may be accomplished through a computer control system or any device capable of RS 232 communication 7 1 1 RS 232 INTERFACE The control commands for the MT108...

Страница 9: ...U0 should be used for single unit operation If the ID is set to U0 each command may be used without Ui Use the command SETU0 as explained in the MT101 101 User s Guide Example VERC3 For U0 VERC3Ui For...

Страница 10: ...ID n slot from 1 to max slots Example Test C4 s memory by sending TESTC4 If all tests pass the following message will be displayed MEMORY IS GOOD Otherwise failures will be indicated 6 HELP This comm...

Страница 11: ...in parentheses The first two characters identify the status type The last three characters are the card s ID MT108 103 Card model number VR690 0127 009 Firmware version ON1110 Output ON OFF status The...

Страница 12: ...t no m from 1 4 Gk Group no k from 1 8 Example ON1G1 Turns on Output 1 for each card in G1 See the GROUP commands for a detailed explanation of groups PATH OPERATION This command will set the path for...

Страница 13: ...e command switches all paths set on this card and all other cards in the enclosure Example ON1C6P OFF3C7P SW ID COMMANDS The default card ID is the same as the card slot number The next several comman...

Страница 14: ...ID n n Offset amount n from 0 to 99 The maximum card ID is 99 so subtract the highest slot number from 99 to find the maximum offset For example in an 8 slot enclosure the maximum offset would be 91 T...

Страница 15: ...back G5 C2C4C6C8 24 RMC This command removes one or more cards from a group Command Format RMCn1Cn2 Gk Cn Card ID n from 1 to max slots Gk Group ID k from 1 8 Example G5 consists of C2 C4 C6 and C8 Re...

Страница 16: ...ould like to offer suggestions for the following 8 1 LED IS NOT LIT Cause 1 Card cage is not plugged in Solution Make sure the enclosure is powered and has AC power turned on If the LED is still not o...

Страница 17: ...excessive amplification Solution 1 Make sure that the source signal level is high enough so that the destination amplifier does not have to provide excessive amplification and thereby distort the sign...

Отзывы: