background image

MULTITASKER

400-0443-004

15

20.  

[SID+]

This command sets the card ID of all cards in a 
system to their slot number plus the offset value.  

Command Format:  [SID+n]

n

= Offset amount (n = # from 0 to 99)

The maximum card ID is 99, so subtract 
the highest slot number from 99 to find 
the maximum offset. For example, in an 
8-slot enclosure, the maximum offset 
would be 91. The slot number (8) plus the 
offset (91) equals 99.

Example:

There are two 20-slot enclosures to be 
connected together during normal operation. 
The first unit will use the default IDs where the 
card ID is equal to the slot number. The second 
unit will have the same unit ID, but each card ID 
will be offset by 20. 

Connect the computer to the second unit only 
and send the command [SID+20] to set the ID of 
all the cards in the second enclosure to their slot 
number plus 20, then reconnect both units.

The cards in the first unit will be referenced as 
card IDs 1-20 and the cards in the second unit 
will be referenced by card IDs 21-40.

21.  

[RSN]

This command displays the slot number of a 
card with a specified ID number. If more than 
one card has the same ID, each slot number will 
be displayed.

Command Format:  [RSNCi]

Ci

= Card ID (i = # from 1 to 99)

Example:

The card in slot 4 takes up four slots in the 
enclosure. Its ID was set to 1 since it is the first 
card installed in the system, reading from left to 
right. Send the command [RSNC1] to find the 
slot number of this card. The system responds 
with the following feedback:

[4]

GROUP COMMANDS

Group commands allow several cards with the 
same functions to be controlled simultaneously with 
a single command. Up to 8 groups (G1-G8) may be 
defined.  These commands apply to all cards, not 
only the 

MT115-111.

 

22.  

[WR]

This command adds cards to a group. In 
MultiTasker systems with audio and video cards, 
the groups are typically as follows:

Group 1 = Video Cards

Group 2 = Audio Cards

Group 3 = Video and Audio Cards

Command Format: [WRCn

1

Cn

2

…Gk]

Cn = Card ID (n = slot # from 1 to max slots)

Gk = Group ID (k = # from 1-8)

Example:

Add C2, C4, and C6 to G5 by sending the 
command  [WRC2C4C6G5]. After executing this 
command, G5 will consist of C2, C4, and C6.

Now add C8 to G5 by sending [WRC8G5]. C8 is 
added to G5, and G5 is not overwritten. View 
the contents of G5 by sending [RDG5] and 
receiving the following feedback:

[G5=C2C4C6C8]

23.  

[RMC]

This command removes one or more cards from 
a group.

Command Format: [RMCn

1

Cn

2

…Gk]

Cn = Card ID (n= # from 1 to max slots)

Gk = Group ID (k = # from 1-8)

Example:

G5 consists of C2, C4, C6, and C8. Remove C6 
and C8 by sending [RMC6C8G5]. View the 
contents of G5 by sending [RDG5] and receiving 
the following feedback:

[G5=C2C4]

Содержание Dual Twisted Pair Receiver to Computer / Component Video + Audio MT115-111

Страница 1: ...MULTITASKER MANUAL PART NUMBER 400 0443 004 DUAL TWISTED PAIR RECEIVER TO COMPUTER COMPONENT VIDEO AUDIO USER S GUIDE MT115 111...

Страница 2: ...DIAGRAM 2 INTERNAL VIEW 7 DIAGRAM 3 SWITCH SETTINGS 8 INSTALLING YOUR MT115 111 9 OPERATION 9 RS 232 CONTROL 9 DESCRIPTION OF COMMANDS 10 COMMAND ORGANIZATION 10 BASIC COMMANDS 10 FEEDBACK CONTROL 12...

Страница 3: ...strong detergents or solvents such as alcohol or thinner Do not use a wet cloth or water to clean the card Do not clean or touch any component or PCB 1 5 FCC NOTICE This device complies with Part 15...

Страница 4: ...ut The SOG feature is a simple switch setting that may be set for SOG or standard RGBHV The latest generation of Twisted Pair devices uses an innovative patented technology developed by ALTINEX The ne...

Страница 5: ...ndard Audio Output Signal Gain 0 dB 0 5 dB Level 1 0 Vp p max Video Output Signal Video Signal 1 0 Vp p max Video Impedance 75 ohm SYNC Signal TTL Video Resolutions VGA through UXGA 480p through 1080i...

Страница 6: ...MULTITASKER 400 0443 004 5 PRODUCT DESCRIPTION 4...

Страница 7: ...MULTITASKER 400 0443 004 6 APPLICATION DIAGRAMS 5 DIAGRAM 1 TYPICAL SETUP MT115 111 TP115 110 TP115 110...

Страница 8: ...H W EQ PAIR 1 PAIR 3 PAIR 2 PAIR 4 SEPARATOR G Y B Pb R Pr H V R Pr G Y B Pb H V CH2 POWER PS MP CH1 DETECT SIGNAL POWER INPUT 1 4TP VIDEO 15 PIN HD YPbPr RGBHV RGBHV YPbPr VIDEO 15 PIN HD RJ 45 4TP R...

Страница 9: ...r HW for a fixed gain 1 Set SW8 to SW for software or HW for a fixed gain 1 Set SW4 to SW for software or HW for hardware Set SW2 to SW for software or HW for hardware Set SW3 to ON for a Sync on Gree...

Страница 10: ...en adjust the equalization on both units for the best image Step 11 The MT115 111 also has video gain adjustment capability through RS 232 control See the following section for RS 232 command details...

Страница 11: ...will significantly affect the commands recorded on software definitions or third party control systems The unit ID has a range from U0 to U20 U0 should be used for single unit operation If the ID is...

Страница 12: ...C4S after reset or power up the equalization for Input 1 will be set to 16 5 CLR This command clears the card settings and returns it to the factory default values The defaults gain setting is 4 and t...

Страница 13: ...T115 111C04 MT115 111 is in slot 4 10 C This command will return general information about the card and its status Command Format Cn Cn Card ID n from 1 to max slots Example The MT115 111 in slot 4 ha...

Страница 14: ...ase the setting by 3 Send the EQ command again to receive new value 15 CARD CONTROL Card control commands allow the main functions of the card to be executed over the RS 232 bus or from the front pane...

Страница 15: ...card ID is to be able to use multiple systems without having to set each unit to a different unit ID All systems may be left as unit ID 0 for ease of programming The cards in the first unit may be nu...

Страница 16: ...ample The card in slot 4 takes up four slots in the enclosure Its ID was set to 1 since it is the first card installed in the system reading from left to right Send the command RSNC1 to find the slot...

Страница 17: ...ake up G5 In this case G5 includes C2 C4 and C6 7 3 SUMMARY OF COMMANDS Basic Commands 1 VER Display firmware version 2 C Display card status 3 CnS Save card settings 4 S Save current setting 5 CLR Re...

Страница 18: ...keyboard 3 The system checks all MultiTaskers on the RS 232 bus and displays a list of available systems Example 1 U1 2 U2 3 U3 4 Enter the ID number of the desired system In the example above enter a...

Страница 19: ...QUALIZATION CONTROL INPUT 1 32 1 INCREASE EQ LEVEL 2 DECREASE EQ LEVEL 2 INPUT 2 32 EQUALIZATION CONTROL INPUT 2 32 1 INCREASE EQ LEVEL 2 DECREASE EQ LEVEL 2 GAIN CONTROL GAIN CONTROL 1 INPUT 1 4 GAIN...

Страница 20: ...TE The status will be displayed followed by the Main Menu being redisplayed TROUBLESHOOTING GUIDE 8 We have carefully tested and found no problems in the supplied MT115 111 unit However we would like...

Страница 21: ...l ALTINEX at 714 990 2300 If there is still no display see Cause 3 Cause 3 Cable connections are incorrect Solution Make sure the cables are properly connected Also make sure that the continuity and w...

Отзывы: