Welcome! 

We greatly appreciate your purchase of the CNK600 Cable-Nook 
Interconnect Box. We are sure you will find it reliable and simple 
to use. Superior performance for the right price, backed by solid 
technical and customer support is what Altinex offers. 

We are committed to providing our customers with Signal 
Management Solutions

®

 to the most demanding audiovisual 

installations at competitive pricing and we welcome you to join the 
ranks of our many satisfied customers throughout the world. 

1. Precautions and Safety Warnings 

Please read this manual carefully before using your CNK600. 
Keep this manual handy for future reference. These safety 
instructions are to ensure the long life of your CNK600 and to 
prevent fire and shock hazards. Please read them carefully and 
heed all warnings. 

1.1 General 

  Qualified ALTINEX service personnel or their authorized 

representatives must perform all service. 

1.2 Installation 

  For best results, place the CNK600 Cable-Nook 

Interconnect Box in a dry area away from dust and 
moisture. 

  To prevent fire or shock, do not expose this unit to water or 

moisture. Do not place in direct sunlight, near heaters or 
heat-radiating appliances, or near any liquid. Exposure to 
direct sunlight, smoke, or steam can harm internal 
components. 

  Handle carefully; dropping or jarring can damage the unit. 

  Never place fingers inside the openings in the back of the 

unit. This action could cause serious injury because of the 
sharp edges inside.  

  Do not place heavy objects on top of the CNK600. 

  Install all cables according to the instructions. 

1.3 Cleaning 

  Clean surfaces with a dry cloth. Never use strong 

detergents or solvents such as alcohol or thinner. Do not 
use a wet cloth or water to clean the unit. 

1.4 FCC Notice 

  This device complies with Part 15 of the FCC Rules. 

Operation is subject to the following two conditions: (1) This 
device may not cause harmful interference, and (2) this 
device must accept any interference received, including 
interference that may cause undesired operation. 

  This equipment has been tested and found to comply with 

the limits for a Class A digital device, pursuant to Part 15 of 
the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when the 
equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency 
energy and if not installed and used in accordance with 
instructions found herein, may cause harmful interference to 
radio communications. Operation of this equipment in a 
residential area is likely to cause harmful interference in 
which case the user will be required to correct the 
interference at his own expense. 

  Any changes or modifications to the unit not expressly 

approved by Altinex

, Inc. could void the user’s authority to 

operate the equipment. 

 
 

2. Installation Procedures 

Note: 

Download and read the entire online manual to become familiar with the CNK600 
and for detailed installation instructions  

Step 1.  Cut an opening into the table for the CNK600. Refer to the Altinex website at 

www.altinex.com

 for table cutout requirements template. Table thickness can be 

3.5 in (89 mm) or less. Always confirm dimensions before cutting; specification 
can change. 

Step 2.  Assemble the SP2116SC/SP2117SC plates with snap-in cables and 

install plates into the CNK600.  

Step 3.  Install any retracts unit to the CNK600 body. Cables feed through the 

CNK bottom plate, retract metal panels, and up through bushing as 
shown. Connect retract metal panel to the SP plate using thumb screws 
attached. Slide bushings into plate openings to provide cable retention. 

Step 4.  Insert assembled CNK600 into opening. Tighten mounting screws to the 

table from the top using provided Arm Hex

–L key. 

Step 5.  Connect cables to their corresponding inputs under the surface. 

3. Limited Warranty/Return Policies 

Please see the Altinex website a

www.altinex.com

 for details on warranty and return policies. 

Содержание Cable-Nook CNK600

Страница 1: ...o conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been...

Страница 2: ...tinex Retractable Cables Accessories Included Mounting Hardware Mounting screws 4pcs Mounting Brackets 4pcs attached to the unit Arm Hex L Key Table 1 CNK600 General Mechanical CNK600 Minimum Table Th...

Страница 3: ...NK600S is brushed aluminum The modular Cable Nook uses a trapdoor type lid that remains flush with the table when not in use To access the cables or connectors simply lift the lid and pull the cable e...

Страница 4: ...CNK600 Interconnect Box User s Guide 400 0643 001 4 6 Application Diagrams Diagram 1 Typical Setup...

Страница 5: ...CNK600 Interconnect Box User s Guide 400 0643 001 5 Diagram 2 Dimensions Top and Front...

Страница 6: ...CNK600 Interconnect Box User s Guide 400 0643 001 6 Diagram 3 Side View Dimensions...

Страница 7: ...availability The plate also has 12 ports for snap in cables that can be customized based on the customer s requirements In addition the SP2116SC plate is designed to be used with up to 4 of any combin...

Страница 8: ...snap in cables that can be customized based on the customer s requirements In addition the SP2117SC plate is designed to be used with up to 4 of any combination of Altinex retractable cables Unused s...

Страница 9: ...CNK600 Interconnect Box User s Guide 400 0643 001 9 Diagram 6 Retractable Cables Mounting...

Страница 10: ...nector from the CNK600 Remember the devices plugged into the AC power connectors should not draw more than the rated values of the cables and or circuit 8 Troubleshooting Guide The CNK600 supplied was...

Отзывы: