8.3 NO REMOTE IMAGE
Cause 1:
The source has a problem.
Solution:
Check the image on the local
monitor and verify the quality is
good. If the local image is good, see
Cause 2.
Cause 2:
Cable connections are incorrect.
Solution:
Make sure that cables are
connected properly. Also, make sure
that the continuity and wiring are
good. If there is still no image, call
ALTINEX at (714) 990-2300.
8.4 REMOTE IMAGE QUALITY IS POOR
Cause 1:
The source has a problem.
Solution:
Check the image on the local
monitor and verify the quality is
good. If the local image is good, see
Cause 2.
Cause 2
Poor signal transmission.
Solution:
Check the cables for continuity and
make sure that connections are
wired properly to verify that there is
good signal transmission. We
recommend ALTINEX-made cables
for best results. If the image is still
not correct, call ALTINEX at
(714) 990-2300.
ALTINEX POLICIES