PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your

DA1406WM

 Distribution Amplifier. Keep this

manual handy for future reference. These safety
instructions are to ensure the long life of your

DA1406WM

 and to prevent fire and shock hazard.

Please read them carefully and heed all warnings.

1.1 GENERAL

 Unauthorized personnel shall not open the unit

since there are high-voltage components inside.

 Qualified Altinex service personnel, or their

authorized representatives must perform all
service.

1.2 SAFETY GUIDELINES FOR THE RACK-

MOUNTING OF THE DA1406WM

    Maximum operating ambient temperature is 35

(degrees C).

    Never restrict the air flow through the devices’

fan or vents.

  When installing equipment into a rack, distribute

the units evenly. Otherwise, hazardous
conditions may be created by an uneven
weight distribution.

   Connect the unit to a properly rated supply

circuit.

   Reliable Earthing (Grounding) of Rack-

Mounted Equipment should be maintained.

1.3 INSTALLATION

 For best results, place the 

DA1406WM

Distribution Amplifier on a flat, level surface in a
dry area away from dust and moisture.

 To prevent fire or shock, do not expose this unit

to rain or moisture. Do not place the

DA1406WM

 Distribution Amplifier in direct

sunlight, near heaters or heat radiating
appliances, or near any liquid. Exposure to
direct sunlight, smoke, or steam can harm
internal components.

 Handle the 

DA1406WM

 Distribution Amplifier

carefully. Dropping or jarring can damage
internal components.

 Do not place heavy objects on top of the

DA1406WM

. If the 

DA1406WM

 is to be mounted

to a table or wall, use only Altinex made
mounting accessories like brackets (

DA1293FC

and 

DA1294FC

) and cables for optimum setup.

 To turn off the main power, be sure to remove

the cord from the power outlet. The power outlet
socket should be installed as near to the
equipment as possible, and should be easily
accessible.

 Do not pull the power cord or any cable that is

attached to the 

DA1406WM

 Distribution

Amplifier.

 If the 

DA1406WM

 Distribution Amplifier is not

used for an extended period, disconnect the
power cord from the power outlet.

1.4 CLEANING

 Unplug the 

DA1406WM

 power cord before

cleaning. Clean surfaces with a dry cloth. Never
use strong detergents or solvents such as
alcohol or thinner. Do not use a wet cloth or
water to clean the unit.

1.5 FCC / CE NOTICE

 This device complies with Part 15 of the FCC

Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.

 This equipment has been tested and found to

comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.

Содержание 1-In, 4-Out DA1957CT

Страница 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0018 003 PRODUCT REVISION 0 DA1406WM 1 IN 6 OUT MAC DISTRIBUTION AMPLIFIER USER S GUIDE...

Страница 2: ...solutions to the most demanding audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfie...

Страница 3: ...n top of the DA1406WM If the DA1406WM is to be mounted to a table or wall use only Altinex made mounting accessories like brackets DA1293FC and DA1294FC and cables for optimum setup To turn off the ma...

Страница 4: ...tor change The DA1406WM is great for desktop use but can also be rack mounted using optional hardware TECHNICAL SPECIFICATIONS 3 FEATURES DESCRIPTION DA1406WM GENERAL Input 1 Input Connector 15 pin D...

Страница 5: ...of the DA1406WM can be easily adapted to 5 BNC connectors to allow it to be used with RGsB RGBS or RGBHV signal types as well This requires the use of Altinex MS8100 series adapter cables 15 pin to 5...

Страница 6: ...zontal Sync Table 5 The DA1406WM Outputs pin out APPLICATION DIAGRAM 5 4 2 BOOT UP SWITCHES Some Video cards require the proper sense ID pins to determine the boot up mode Sense pins are usually prese...

Страница 7: ...he input channel of the amplifier Then connect the output channels of the amplifier to the display devices i e monitors or projector Step 4 If the image is less than perfect check all the connections...

Страница 8: ...ier A Distribution Amplifier is a device that allows you to connect a single video source to multiple display devises such as monitors or projectors used in presentation applications 2 May I have on t...

Страница 9: ...ability in connection with the sale of the products This warranty shall not apply to any product that shall have been repaired or altered outside of company s factory in any way so as in its judgment...

Отзывы: