The first (outer-most) Quantum board ID should be set as 0, the next board

ID as 1, and so forth. Do not skip slots between boards. Refer to the 

Quantum

Quick Installation Guide

for proper installation instructions.

S

TEP

2: I

NSERT

T

RITON

T1 B

OARD

(

S

) I

NTO

PCI S

LOTS

After installing the Triton T1 Board(s), make sure the Triton T1 board ID is

set properly. The first (outer-most) Triton T1 Board should be set at 0, the

next board ID as 1, and so forth. Do not skip slots between boards.

The T1 Boards must be set with ID ranges of 0 - 3. If 4 or greater is

selected as the Board ID, the board will not function.

NOTE!

If Triton VoIP Boards are installed, the T1 Board should begin with

ID of 0 and should be the first (outer-most) boards, followed by the VoIP

Boards.

Triton

Quantum

0    1       

CPU

3     2     1     0

CPU

Содержание TRITON T1

Страница 1: ... ISA 233 Mhz 2GB 1 Triton T1 1 6 Quantum 2 PCI 6 ISA 300 Mhz 2GB 1 4 Triton T1 1 10 Quantum 5 PCI 10 ISA 350 Mhz 4GB of AltiGen Boards Power Supply Typical Power Supply 1 Triton T1 1 3 Quantum 12V 4 2 Amps 5V 6Amps 300W 30A 5V 12A 12V 1 Triton T1 1 6 Quantum 12V 8 4 Amps 5V 10 8Amps 400W 40A 5V 16A 12V 1 4 Triton T1 1 10 Quantum 12V 14 Amps 5V 21Amps 400W 40A 5V 16A 12V GREEN LED RED LED Status OF...

Страница 2: ... After installing the Triton T1 Board s make sure the Triton T1 board ID is set properly The first outer most Triton T1 Board should be set at 0 the next board ID as 1 and so forth Do not skip slots between boards The T1 Boards must be set with ID ranges of 0 3 If 4 or greater is selected as the Board ID the board will not function NOTE If Triton VoIP Boards are installed the T1 Board should begin...

Страница 3: ...PEN DO NOT TWIST THE MVIP CABLE It should lay flat when connected to boards as shown below Quantum Triton CPU Board MVIP Bus Termination Switch CLOSE OPEN CLOSE Power RJ48c or RJ 48x cable RJ48c or RJ 48x cable Network Termination Box Central Office Net T1 Line CSU CPE For T1 Socket RJ 48 Receive Ring Pin 1 Receive Tip Pin 2 Transmit Ring Pin 4 Receive Tip Pin 5 0 1 CPU 3 2 1 0 For Adtran CSU NOTE...

Страница 4: ...ry _______ Hard Drive _______ of AltiGen boards installed Quantum________ Triton ________ Description of the problem __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ AltiGen Communications Inc www altigen com Alti...

Отзывы: